BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
TYPE YAZ
UNINSULATED COPPER
COMPRESSION TERMINAL
UL Listed 90° C,
600 Volts to 35 KV
◆
B
ELECTRO-TIN
PLATED
DIE AND COLOR
CODE INFORMATION
INSPECTION
WINDOW
BEVELED
ENTRY
CRIMP
CABLE
ACCOMMODATION
C-21
B
90°
B
T
L
T
L
45°
T
L
Fig. 1
Conductor
Catalog Number
YAZV10-TC14
YAZV10-TC14-45
YAZV10-TC14-90
YAZ8C-TC10
YAZ8C-TC10-45
YAZ8C-TC10-90
YAZ8C-TC14
YAZ8C-TC14-45
YAZ8C-TC14-90
YAZ8C-TC38
YAZ8C-TC38-45
YAZ8C-TC38-90
YAZ6C-TC14
YAZ6C-TC14-45
YAZ6C-TC14-90
YAZ6C-TC38
YAZ6C-TC38-45
YAZ6C-TC38-90
YAZ6C-TC12
YAZ6C-TC12-45
YAZ6C-TC12-90
YAZ5C-TC12
YAZ5C-TC12-45
YAZ5C-TC12-90
YAZ4C-TC14
YAZ4C-TC14-45
YAZ4C-TC14-90
YAZ4C-TC38
YAZ4C-TC38-45
YAZ4C-TC38-90
YAZ4C-TC12
YAZ4C-TC12-45
YAZ4C-TC12-90
Fig #
AWG
1
#14 - 10 Str
2
#12 - 10 Sol
3
1
2
3
#8 AWG
1
#8 WELD
2
37/24
3
#6 SOL
1
2
3
1
2
3
1
2
#6 AWG
3
1
2
3
1
2
#5 AWG
3
1
2
3
1
2
#4 AWG
3
1
2
3
***
MM
2
6
Stud
Hole
Size
1/4
Tongue
Width
.41
.
.41
Figure
Dimensions
(B)
(T)
(L)
1.54
.69
.05
1.41
.83
1.58
.75
.08
1.47
.75
1.71
.75
.08
1.58
.87
1.89
.75
.06
1.72
1.05
2.03
1.12
.08
1.83
.89
2.22
1.12
.06
1.97
1.06
2.65
1.12
.12
2.54
1.53
2.68
1.12
.12
2.56
1.53
2.05
1.12
.09
1.87
.92
2.23
1.12
.08
2.01
1.09
2.67
1.12
.12
2.55
1.55
Dieless
(# of crimps)
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
-
-
-
Fig. 3
Wire
Color Die Strip
Code Index Length
-
-
3/4
Y8MRB-1
#10
†
10
1/4
.44
W8CVT (2) W8CVT (2)
W8CRT (2) W8CRT (2)
X8CRT (2) X8CRT (2)
Y1MR (2)
Y2MR (2)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
W5CVT (2)
Y644M (1)
W5CRT (2)
X5CRT (2)
X8CART (2)
U8CRT (2)
Red
49
7/8
1/4
.58
1/4
.45
.
.58
-
3/8
W5CVT (2)
W5CRT (2)
X5CRT (2)
X8CART (2)
U5CRT (2)
U8CABT (2)
Blue
7 or
1-3/16
374
1/2
-
1/2
.83
.
.
.83
W5CRT (2) W5CVT (2)
W5CVT (2) X5CRT (2)
X5CRT (2) W5CRT (2)
Y1MR (4)
Y2MR (4)
W4CVT (2) W4CVT (2)
MY29-3 (2)
W4CRT (2) W4CRT (2)
MY29-11 (2)
X4CRT (2) X4CRT (2)
MRC840 (2)
Y644M (1)
U5CRT (2)
Blue
7 or
1-3/16
374
1/4
.49
-
3/8
.58
U4CRT (2)
U6CABT (2)
Gray
8 or
1-3/16
346
1/2
.83
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
† The MM
2
conductor size listed is for Class 2 and Class 5
conductor.
▲
See tooling section of this catalog for complete tool and
die listings.
• Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Conductor
C-22
Catalog Number
YAZ3C-TC14
YAZ3C-TC14-45
YAZ3C-TC14-90
YAZ3C-TC38
YAZ3C-TC38-45
YAZ3C-TC38-90
YAZ3C-TC12
YAZ3C-TC12-45
YAZ3C-TC12-90
YAZ2C-TC14
YAZ2C-TC14-45
YAZ2C-TC14-90
YAZ2C-TC38
YAZ2C-TC38-45
YAZ2C-TC38-90
YAZ2C-TC12
YAZ2C-TC12-45
YAZ2C-TC12-90
YAZ1C-TC14
YAZ1C-TC14-45
YAZ1C-TC14-90
YAZ1C-TC38
YAZ1C-TC38-45
YAZ1C-TC38-90
YAZ1C-TC12
YAZ1C-TC12-45
YAZ1C-TC12-90
YAZ25-TC14
YAZ25-TC14-45
YAZ25-TC14-90
YAZ25-TC516
YAZ25-TC516-45
YAZ25-TC516-90
YAZ25-TC38
YAZ25-TC38-45
YAZ25-TC38-90
YAZ25-TC12
YAZ25-TC12-45
YAZ25-TC12-90
YAZ26-TC14
YAZ26-TC14-45
YAZ26-TC14-90
YAZ26-TC38
YAZ26-TC38-45
YAZ26-TC38-90
YAZ26-TC12
YAZ26-TC12-45
YAZ26-TC12-90
YAZ27-TC38
YAZ27-TC38-45
YAZ27-TC38-90
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
***
MM
2
Stud
Hole
Size
1/4
#3 AWG
25
#2 SOL
1/2
.83
3/8
.58
Tongue
Width
.55
Figure
Dimensions
(B)
(T)
(L)
2.21
1.25
.09
1.97
.93
2.39
1.25
.08
2.13
1.11
2.83
1.25
.07
2.66
1.57
2.23
1.25
.11
2.03
.96
2.41
1.25
.11
2.21
1.14
2.85
1.25 .09
2.57
1.57
2.39
1.38
.10
2.13
.98
2.57
1.38
.10
2.31
1.16
3.01
1.38
.09
2.7
1.59
2.42
1.38
.12
2.19
1.02
2.47
1.38
.12
2.24
1.08
2.6
1.38
.12
2.37
1.2
3.04
1.38
.12
2.77
1.63
2.58
1.50
.12
2.3
1.04
2.76
1.50
.12
2.48
1.22
3.2
1.50
.12
2.92
1.66
2.8
1.50
.12
2.52
1.25
Dieless
(# of crimps)
B
B
90°
B
T
L
T
L
45°
T
L
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
Fig. 3
Wire
Color Die Strip
Code Index Length
W3CRT (2) W3CRT (2)
Y1MR (4)
Y2MR (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
Y644M (1)
W2CVT (2) W2CVT (2)
W2CRT (2) W2CRT (2)
X2CRT (2) X2CRT (2)
U3CRT (2)
White
9
1-5/16
1/4
.60
#2 AWG
35
3/8
.60
U2CRT (2)
Brown
10
1-5/16
1/2
.83
1/4
.67
#1 AWG
50
3/8
.67
Y1MR (4)
MY29-3 (2) W1CVT (2) W1CVT (2)
MY29-11 (2) W1CRT-1 (2) W1CRT-1 (2)
MRC840 (2) X1CRT-1 (2) X1CRT-1 (2)
Y644M (1)
U1CRT-1 (2)
U4CABT (2)
Green
11 or
1-7/16
375
1/2
.83
1/4
.75
5/16
1/0 AWG
-
3/8
.75
W25VT (4) W25VT (4)
W25RT (4) W25RT (4)
X25RT (4) X25RT (4)
U25RT (2)
U2CABT (2)
Pink
12 or
1-7/16
348
.75
1/2
.83
1/4
.83
MY29-3 (2)
MY29-11 (2)
MRC840 (4)
Y644M (1)
W26VT (4) W26VT (4)
W26RT (4) W26RT (4)
X26RT (4) X26RT (4)
2/0 AWG
70
3/8
.83
U26RT (2)
Black
13 1-9/16
1/2
.83
3/0 AWG
-
3/8
.90
W27RT (4) W27VT (4)
W27VT (4) W27RT (4)
X27RT (6) X27RT (6)
U27RT (2)
Orange
14 1-9/16
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and die
listings.
• Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Conductor
Catalog Number
YAZ27-TC12
YAZ27-TC12-45
YAZ27-TC12-90
YAZ28-TC38
YAZ28-TC38-45
YAZ28-TC38-90
YAZ28-TC12
YAZ28-TC12-45
YAZ28-TC12-90
YAZ29-TC38
YAZ29-TC38-45
YAZ29-TC38-90
YAZ29-TC12
YAZ29-TC12-45
YAZ29-TC12-90
YAZ30-TC38
YAZ30-TC38-45
YAZ30-TC38-90
YAZ30-TC12
YAZ30-TC12-45
YAZ30-TC12-90
YAZ31-TC38
YAZ31-TC38-45
YAZ31-TC38-90
YAZ31-TC12
YAZ31-TC12-45
YAZ31-TC12-90
YAZ32-TC38
YAZ32-TC38-45
YAZ32-TC38-90
YAZ32-TC12
YAZ32-TC12-45
YAZ32-TC12-90
YAZ33-TC12
YAZ33-TC12-45
YAZ33-TC12-90
YAZ34-TC38
YAZ34-TC38-45
YAZ34-TC38-90
YAZ34-TC12
YAZ34-TC12-45
YAZ34-TC12-90
YAZ35-TC12
YAZ35-TC12-45
YAZ35-TC12-90
YAZ36-TC38
YAZ36-TC38-45
YAZ36-TC38-90
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
3/0 AWG
***
MM
2
-
Stud
Hole
Size
1/2
Tongue
Width
.91
Figure
Dimensions
(B)
(T)
(L)
3.23
1.5
0.12
2.96
1.69
2.99
1.62 0.14
2.69
1.3
3.4
1.62 0.14
3.11
1.73
2.99
1.62 0.16
2.73
1.34
3.43
1.62 0.16
3.17
1.77
3.42
2
.16
3.04
1.37
3.85
2
.16
3.48
1.81
3.45
2
0.18
3.1
1.41
3.89
2
0.18 3.54
1.85
3.62
2.12
.19
3.25
1.46
4.06
2.12
.19
3.69
1.89
4.14
2.12
.21
3.79
1.95
3.85
2.25
.23
3.5
1.54
4.29
2.25
.23
3.94
1.98
4.7
2.62
.25
4.28
2.02
4.55
2.69
.26
4.14
1.81
Dieless
(# of crimps)
B
B
90°
B
T
L
T
L
45°
T
L
Fig. 1
Fig. 2
▲
Installation Tooling
Hydraulic
BCT500HS,
Y35,Y39,Y750,
Y500CTHS
Y46*, PAT750
W27VT (4)
W27RT (4)
U27RT (2)
X27RT (6)
Fig. 3
-
4/0 AWG
-
3/8
1.02
1/2
1.02
MY29-3 (2)
MY29-11 (2)
MRC840 (4) W28VT (4) W28VT (4)
Y644M (1) W28RT (4) W28RT (4)
X28RT (6) X28RT (6)
Mechanical
MD6, OUR840,
MD7-34R
W27RT (4)
W27VT (4)
X27RT (6)
Wire
Color Die Strip
Code Index Length
Orange 14 1-9/16
C-23
U28RT (2)
Purple
15 1-11/16
3/8
250 kcmil
-
1/2
1.10
1.10
MY29-3 (2)
W29VT (4)
MY29-11 (2)
X29RT (8)
Y644M (1)
W29VT (4)
W29RT (4)
X29RT (6)
U29RT (2)
Yellow
16 1-11/16
3/8
300 kcmil
150
1/2
1.20
W30VT (4)
W30VT (4)
W30RT (4)
U30RT (4)
U28ART (4)
White
17 or
2-1/16
298
1.20
3/8
350 kcmil
185
1/2
1.29
W31VT (4)
W31VT (4)
W31RT (4)
U31RT (4)
U29ART (4)
Red
18 or
2-1/16
324
1.29
-
400 kcmil
-
3/8
1.40
W32VT (4)
Y644M (1)
W32VT (4)
W32RT (4)
U32RT (4)
U30ART (4)
Blue
19 or
2-3/16
470
1/2
1.40
450 kcmil
-
1/2
1.48
W33VT (4)
W33VT (4)
W33RT (4)
U33RT (4)
Gray
326 2-5/16
3/8
500 kcmil
240
1/2
1.55
W34VT (4)
W34VT (4)
W34RT (4)
U34RT (4)
U31ART (4)
Brown
20 or
2-5/16
299
1.55
550 kcmil
-
1/2
1.65
-
-
U35RT (4)
U36RT (4)
U32ART (4)
Yellow
21 2-11/16
22 or
472
600 kcmil
300
3/8
1.74
-
-
Green
2/4
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and
die listings.
• Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(Continued)
Conductor
C-24
Catalog Number
YAZ36-TC12
YAZ36-TC12-45
YAZ36-TC12-90
YAZ37-TC12
YAZ37-TC12-45
YAZ37-TC12-90
YAZ38-TC12
YAZ38-TC12-45
YAZ38-TC12-90
YAZ39-TC38
YAZ39-TC38-45
YAZ39-TC38-90
YAZ39-TC12
YAZ39-TC12-45
YAZ39-TC12-90
YAZ39-NT12
YAZ39-NT12-45
YAZ39-NT12-90
YAZ40-TC12
YAZ40-TC12-45
YAZ40-TC12-90
YAZ41-TC12
YAZ41-TC12-45
YAZ41-TC12-90
YAZ44-TC38
YAZ44-TC38-45
YAZ44-TC38-90
YAZ44-TC12
YAZ44-TC12-45
YAZ44-TC12-90
YAZ45-TC12
YAZ45-TC12-45
YAZ45-TC12-90
YAZ453-TC12
YAZ453-TC12-45
YAZ453-TC12-90
YAZ46-TC12
YAZ46-TC12-45
YAZ46-TC12-90
YAZ47-TC12
YAZ47-TC12-45
YAZ47-TC12-90
YAZ48-TC12
YAZ48-TC12-45
YAZ48-TC12-90
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
600 kcmil
***
MM
2
300
Stud
Hole
Size
1/2
Tongue
Width
1.74
Figure
Dimensions
(B)
(T)
(L)
4.80
2.69
.26
4.39
2.06
4.95
2.81
.27
4.51
2.09
4.97
2.81
.27
4.51
2.09
4.82
2.88
.27
4.34
1.87
5.07
2.88
.27
4.59
2.12
5.07
2.88
.27
4.59
2.12
5.14
2.94
.30
4.71
2.16
5.16
2.94
.31
4.73
2.18
5.09
3.00
.33
4.66
2.02
5.33
3.00
.33
4.91
2.27
5.63
3.19
.38
5.24
2.38
5.66
3.19
.39
5.28
2.41
5.73
3.19
.40
5.35
2.47
6.07
3.44
.42
5.65
2.55
6.14
3.44
.46
5.79
2.65
Dieless
(# of crimps)
B
B
90°
B
T
L
T
L
45°
T
L
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
-
-
U36RT (4)
Fig. 3
Wire
Color Die Strip
Code Index Length
Green
22 or
472
2/4
650 kcmil
-
1/2
1.80
-
-
U37RT (4)
Orange 23
2-7/8
700 kcmil
-
1/2
1.84
-
-
U38RT (4)
Pink
400 2-7/8
3/8
1.91
750 kcmil
-
1/2
1.91
-
Y644M (1)
-
U39RT (4)
P39RT (4)
**
Black
24 2-15/16
1/2
1.63
800 kcmil
400
1/2
1.98
-
-
P40RT (4)
**
-
Orange 25
3
850 kcmil
-
1/2
2.01
-
-
Gold
26
3
3/8
1000 kcmil
500
1/2
2.19
-
-
P44RT (4)
**
White
27 3-1/16
2.19
1250 kcmil
-
1/2
2.46
-
-
P45RT (6)
**
-
Yellow
29
3-1/4
1300 kcmil
-
1/2
2.53
-
-
Orange 30 2-1/16
1500 kcmil
1/2
2.69
-
-
P46RT (6)
**
-
Green
31 3-5/16
1750 kcmil
-
1/2
2.90
-
-
Gray
33
3-1/2
2000 kcmil
1/2
3.10
-
-
-
Brown
34
3-1/2
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and die
listings.
• Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆
For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.