D
ual
R
elays
25-40A
mp
• 120/240, 480 V
ac
• AC OUTPUT
• Zero Voltage
and
Random
Turn-On Swi
tching
• SCR Output
• Industry Standard Package
• Panel M
ount
Two totally independent AC output
relays come in a single standard panel-
mount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zero-
voltage or random turn-on (phase con-
trollable) switching.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
H12D4825D
H12D4825DE
H12D4840D
H12D4840DE
MODEL NUMBERS
OUTPUT SPECIFICATIONS
➀
Operating Voltage (47-63 Hz) [Vrms]
Load Current Range
➂
[Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
θJC
) [ûC/W]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
➁
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
D2425D
D2425DE
D2440D
D2440DE
24-280
.15-25
600
250
1.6
1.02
260
10
500
1/2 cycle
1/2 cycle
0.5
24-280
.15-40
600
625
1.6
.63
1620
10
500
1/2 cycle
1/2 cycle
0.5
48-530
.15-25
1200
250
1.6
1.02
260
10
500
1/2 cycle
1/2 cycle
0.5
48-530
.15-40
1200
625
1.6
.63
1620
10
500
1/2 cycle
1/2 cycle
0.5
➀
➃
INPUT SPECIFICATIONS
➀
Control Voltage Range
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix)
D24XXD
4-15Vdc
4.0 Vdc
1.0 Vdc
300 Ohms
13mA
H12D48XXD
4-15Vdc
4.0 Vdc
1.0 Vdc
240 Ohms
13mA
E-SUFFIX
15-32Vdc
15 Vdc
1.0 Vdc
1500 Ohms
15mA
GENERAL NOTES
© 2003 CRYDOM CORP, Specifications subject to change without notice.
➀
All parameters at 25˚C and per section unless otherwise specified.
➁
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂
Heat sinking required, for derating curves see page 2.
➃
Turn-on time for random turn-on (-10) versions is 0.1 msec.
Crydom Heat Sinks
offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom's Heat Sink specifica-
tion sheet for all the details.
FastFax Document No. 165
DUAL.
Rev. 111203
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506
D
ual
R
elays
25-40A
mp
• 120/240, 480 V
ac
• AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength50/60Hz Input/Output/Base
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
M ECHANICAL SPECIFICATIONS
Weight: (typical)
4000 Vrms
10
9
Ohm
10 pF
-40 to 80˚C
-40 to 125˚C
3.0 oz. (86.5g)
Encapsulation:
Terminals:
120/240 V MO DEL
AVAILABLE OPTIONS
-10
Thermally Conductive Epoxy
.25' Fastons, .025' Square Pins
480V MO DEL
FASTON
TERMINAL
.250 X .032
(4 PLACES)
Random Turn-On,
Phase Controllable
Example:
D2440D-10
15-32Vdc Control
Example:
H12D4840DE
Heat Transfer Pad (Attached)
Example:
D2440DH
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
A2
A1
1.17
(29.7)
1.00
(25.4)
B1
B2
120/24OV - 20A
.15
(3.8)
.250 X .032 FASTON
TERMINAL
(4 PLACES)
MOUNTING HOLE/SLOT
.017 (4.3) DIA.
2 PLC'S
.55
(14.0)
A1 A2
120/24OV - 20A
B1 B2
120/24OV - 20A
120/24OV - 20A
E
2.30
1.87
(58.4)
(47.5)
CONTROL
A
4-15VDC
±
CONTROL
B
±
4-15VDC
2.30
(58.4)
CONTROL
1.87 1.60
(47.5) (40.6)
A
CONTROL
B
H
.50
(12.7)
PIN .025 SQ.
.100 CENTERS
4 PLACES
.45
(11.4)
.85
(21.6)
1.31
(33.2)
-
+
-
+
.77
(19.6)
1.37
(34.8)
1.80
1.80
(45.7)
.187 X .032
FASTON
TERMINAL
(4 PLACES)
.85
(21.6)
1.31
(33.2)
All dimensions are in inches (millimeters)
25A
50A LIMIT
(2 SECTIONS)
CURRENT DERATING CURVES
Max Allowable Base Temp. [˚C]
40A
Max Allowable Base Temp. [˚C]
Power Dissipation [W]
0.5˚C/W
75
85
40
25A LIMIT
(1 SECTION)
2.0˚C/W
1.0˚C/W
Power Dissipation [W]
100
80
60
40
20
0
20
40
40A LIMIT
(1 SECTION)
80A LIMIT
(2 SECTIONS)
0.5˚C/W
95
105
20
5.0˚C/W
90
95
100
105
1.0˚C/W
2.0˚C/W
5.0˚C/W
0
10
20
30
40
50
10
20
30
40
50
60
70
80
Load Current [Arms]
Max Ambient Temp. [˚C]
60
80 100 10
20
30
40
50
60
70
80
Load Current [Arms]
Max Ambient Temp. [˚C]
LOAD B
480Vrms
120/240Vrms
A2
LOAD A
A1
B1
B2
LOAD B
120/240Vrms
LOAD A
480Vrms
240V Model
W IRING DIAGRAM S
-- B CONTROL
+ B CONTROL
-- A CONTROL
+ A CONTROL
A1 A2
B1 B2
480V Model
-- A CONTROL
+ A CONTROL
+ B CONTROL
-- B CONTROL
APPROVALS
UL E116949
CSA LR81689 (240V only)
VDE 5902 UG
FastFax Document No. 165
DUAL.
Rev. 111203
PAGE 2 OF 2
©2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506