EEWORLDEEWORLDEEWORLD

Part Number

Search

246FXX33-6F12VDC

Description
On-Delay Relay, 6PST, Momentary, 0.208A (Coil), 12VDC (Coil), 2500mW (Coil), 10A (Contact), 28VDC (Contact), 6s, DC Input, AC/DC Output, Through Hole-Straight Mount
CategoryMechanical and electronic products    relay   
File Size447KB,2 Pages
ManufacturerStruthers-Dunn
Download Datasheet Parametric View All

246FXX33-6F12VDC Overview

On-Delay Relay, 6PST, Momentary, 0.208A (Coil), 12VDC (Coil), 2500mW (Coil), 10A (Contact), 28VDC (Contact), 6s, DC Input, AC/DC Output, Through Hole-Straight Mount

246FXX33-6F12VDC Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
body width37.2 mm
body height95.2 mm
Body length or diameter66.8 mm
Maximum coil current (DC)0.208 A
Coil operating voltage (DC)9.6 V
Coil power2500 mW
Coil resistance57.69 Ω
Maximum coil voltage (DC)12 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
timed delay6 s
Manufacturer's serial number246
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
physical size66.8mm X 37.2mm X 95.2mm
GuidelineCSA; UL
Relay actionMOMENTARY
Relay function6PST
Relay typeON-DELAY RELAY
surface mountNO
Termination typeSOLDER
Base Number Matches1
246/247 Series - Timer Delay Relay
DPDT, 4PDT,6PST, 10 Amp
Rugged, industrial time delay versions of the popular 219 series. Contacts can be configured up
to four pole double throw or six pole single throw. Time ranges are adjustable over a 1:10 range.
Knob adjustment and integral hold down clip are standard. A large option list makes this product
easily customized for special applications.
E13224
GENERAL SPECIFICATIONS (@ 25° C)
Timing:
Functions Available
Time Range
Timing Adjustment
Timing Repeatability
(Constant voltage and temperature)
Reset Time maximum
Input Pulse Length minimum
Contacts:
Contact Configuration
Contact Material
Contact Rating
120 / 240VAC Resistive
28VDC Resistive
Motor 120VAC
Motor 240VAC
Minimum Contct Load
Contact Resistance, Initial
Coil:
Coils Available
Nominal Coil Power
Input Voltage Tolorance -AC
Input Voltage Tolorance -DC
Transient Protection
Reverse Polarity Protection
Duty
Dielectric Strength:
Across Open Contacts
Between Mutally Insulated Points
Insulation Resistance
Temperature:
Operating
Storage
Life Expectancy:
Electrical (full load operations)
Mechanical (no load operations)
Miscellaneous:
Mounting Position
Mating Socket
Accessories
Enclosure
Weight
On-delay, Off-delay
Up to 10 minutes
Knob
3%
150mS
50mS
DPDT, 4PDT, 6PST
Silver Alloy Gold Diffused
10 Amp / 5 Amp
10 Amp
-
-
500mW
100 milliohms max @ 6VDC, 1A
AC and DC
5VA 2.5W
85% to 110% of nominal
80% to 110% of nominal
Yes
Yes
Continuous
500Vrms
1500Vrms
1,000 Mohms min @ 500VDC
-20 to 70°C (-4 to 158°F)
-40 to 105°C (-40 to 221°F)
100,000
10,000,000
Any
12 pin =27390, 27390D
14 pin = 33377, 33377D
Hold down clip integral to relay
Clear Polycarbonate
8.6oz (244 grams)
with socket
Industrial Pin Out
Note: SM = Single make
DM = Double make
Voltage
Make
Carry
Resistive Inductive
120VAC
30 Amp 10 Amp 10 Amp
3 Amp
240VAC
30 Amp 10 Amp 5 Amp
1 Amp
24VDC
30 Amp 10 Amp 10 Amp
5 Amp
28VDC
30 Amp 10 Amp 10 Amp
3 Amp
125VDC
30 Amp 10 Amp 0.5 Amp
0.1 Amp
For versions with suffix “69” permant magnet blowouts
Voltage
Make
Carry
Resistive Inductive
125VDC (SM) 30 Amp 10 Amp 1.5 Amp
0.5 Amp
125VDC (DM) 30 Amp 10 Amp
4 Amp
1.5 Amp
250VDC (SM) 30 Amp 10 Amp
0.5 Amp 150 mAmp
250VDC (DM) 30 Amp 10 Amp 1.5 Amp
0.5 Amp
246/247 Contact Load Specifications
7/9
www.struthers-dunn.com
(843) 664-3303
If conditional statement
I used to think that if conditional statements were very simple and had no restrictions. However, when I was working on a project recently, I needed to make a range judgment on the water level, but th...
liuming759 Microcontroller MCU
Factory automation system uses industrial Ethernet switches to lay industrial Ethernet communication lines
Ethernet has now penetrated into all levels of society, especially office automation is now completely based on Ethernet. There are many solutions to how to seamlessly combine factory automation contr...
dxhdkj Industrial Control Electronics
Is VxSim of limited use in driver development?
VxSim- is a comprehensive VxWorks simulator that provides a debugging and simulation runtime environment that is consistent with the real target machine, allowing developers to quickly start software ...
starben Embedded System
pic16f1823 c program compilation problem
: [i=s]This post was last edited by dingzy_2002 on 2016-6-10 01:14[/i] This is my first time using a PIC microcontroller, pic16f1823 c program. When I compile it with MPLAP IDE8.92 and HI-TECH PICC, t...
一线光辉 Microchip MCU
Tips and precautions for matching amplifiers and speakers
[size=4]For the matching problem between power amplifier and sound system, in addition to the soft matching of sound (the sound matching is often divided into soft and hard, which is the characteristi...
Jacktang Analogue and Mixed Signal
Is my understanding correct about the DCO of the MSP430?
1. For MSP430F14X series, if no crystal is connected externally, the internal DCO is used at startup, and the frequency is 800K.2. For MSP430F449, if DCO is used, an external LFXT1 crystal must be con...
makeawish Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2267  2342  1106  1972  960  46  48  23  40  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号