LB130S
130W Single Output LED Supply
Features
3” x 5” x 1.3” Package
130 Watts
Class B Conducted EMI
70
°
C Ambient Operation with
No
derating
(Conduction Cooled)
Universal Input 90-264Vac
Meets IEC61000-3-2 Class C for 0% to 100%
LED Dimming Applications(5 Watts to 130
Watts)
EN60950 2
nd
Edition
3 Year Warranty
RoHS Compliant
Description
The LB130 model is the highest density conduction cooled power supply in a compact 3X5 package. Providing
130 Watts of power at 70° ambient, the LB130 is designed to meet global lighting requirements and has a
C
built-in EMI filter to meet EN55015 class B. With over 50,000 hours of life expectancy at 70
°
C, the LB130
supports the requirements of the Design Lighting Consortium (DLC) standard.
Model Chart
Model
Number
LB130S56K
Maximum
Output
Current
Volts
56V
2.32
Minimum
Load
0A
Ripple &
Noise*
560mV pk-pk
Total
Regulation
±
3%
OVP
Threshold
66V± 4V
±
* Ripple is 800mV pk-pk @ -10°C
General Specifications
AC Input
Input Current
Inrush Current
Input Fuses
Earth Leakage
Current
Efficiency
www.slpower.com
100-240Vac, ±10%, 47-63Hz, 1∅
Turn On Time
Hold-up Time
Overtemperature
Protection
Overload
Protection
Short Circuit
Protection
Overvoltage
Protection
Less than 3 sec. @115Vac, Full Load
Max. 115Vac: 1.8A, 230Vac: 0.9A
< 55A peak, 264Vac, cold start, turn on
at AC zero crossing
F1, F2: 4A, 250Vac fuses provided on all
models
<500µA@264Vac, 60Hz, NC
20mSec at 130W, 120Vac/60Hz
Sensing transformer temperature, 165°
C
latching type, requires input power
recycling to reset.
Hiccup Mode
Hiccup Mode, auto recovery.
Minimum of 90%
OVP latch
LB130S56K REV 1.9 15-APRIL-14
LB130S
130W Single Output LED Supply
Output Power
Maximum of 130 Watts conduction at
70°
C
200 Watts of peak for minimum of 60
Sec @ 50°
C
500µS typical, return to 0.5% of nominal,
∆i/∆t:
<0.2A/µS. Max Voltage Deviation
= 3%
Test Conditions:
a)5% to 50% load change
b)50% to 100% load change
c)100% to 50%
d)50% to 5%
Switching
Frequency
PFC: Fixed, 65kHz
Main Converter: Variable 35-200kHz, 65-
70kHz at full load
Transient
Response
Isolation
Input-Output: 3,000Vac
Input-Ground: 1,800Vac
Output-Ground: 1,500Vac
Ripple and
Noise
0.5%rms, 1% pk-pk, see chart.
Operating
Temperature
Conduction Cooled:
-10° to +70° Full
C
C
Load
Convection Cooled:
-10° to +50° Full
C
C
Load, 110 Watts @ 60° 90 Watts @70C
C,
Start Up at -40°
C
To maintain Safety approval & life
expectancy, heat-sink temperature should
not exceed 85°
C
-40° to +85°
C
C
Output Voltage
Voltage
Adjustability
Minimum Load
56V
Heat-Sink
Temperature
Storage
Temperature
Altitude
Relative
Humidity
Shock
Safety
Standards
Life
Fixed Output
Not required
Operating: -457 to 3000 m
Non-operating: -457 to 12,192m.
Total Regulation
+/- 3% combined line, load and initial
setting.
Operating: 0.003g²/Hz, 1.5grms overall,
3 axes, 10 min/axis
Non-Operating: 0.026g²/Hz, 5.0grms
overall, 3 axes, 1 hr/axis
W: 3.0” x L: 5.0” x H: 1.3”
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10ms, 3 axes,
6 shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms,
3axes, 6 shocks total
EN/CSA/UL/IEC 60950-1, 2nd Edition
50,000 Hrs at 70° 130 Watts of output,
C,
115Vac or 230Vac input Voltage
Vibration
Dimensions
Weight
380g
The specification above is based on 25° ambient
.
C
www.slpower.com
LB130S56K REV 1.9 15-APRIL-14
LB130S
130W Single Output LED Supply
EMI/EMC Compliance
Conducted Emissions
Radiated Emissions
Static Discharge Immunity
Radiated RF Immunity
EFT/Burst Immunity
Line Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field Immunity
Voltage Dip Immunity
Line Harmonic Emissions
Flicker Test
EN55015 Class B, FCC Part 15, Subpart B, Class B
EN55022 Class A, FCC Part 15, Subpart B, Class A w/6db margin
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
EN61000-4-3, 3V/m.
EN61000-4-4, 2kV/5kHz
EN61000-4-5, 1kV differential, 2kV common-mode
EN61000-4-6, 3Vrms
EN61000-4-8, 3A/m
EN61000-4-11, 100%, 10ms; 30%, 275ms; 60%, 100ms;
Performance
Criteria A, A, & A at 70% load.
EN61000-3-2, Class C from no load to 100% load
EN61000-3-3, Complies (dmax<6%)
Mechanical Drawing
Notes:
1.
All dimensions
in inches (mm), tolerances
are mentioned for each measurement
2. Mounting holes should be grounded for
EMI purposes.
3. FG is safety ground connection.
4. The power supply requires mounting on
metal standoffs 0.20” (5mm) in height, min.
Connector Information
Input Connector
J100
PIN 1) AC LINE
PIN 2) EMPTY
PIN 3) AC NEUTRAL
Mating Connector:
AMP Molex 640250-3
Pins: 640252-2
Ground
(FG)
0.25” FASTON TAB
DC Output Connector
J300
Term. 1,2,3: RTN
Term. 4,5,6: +Vout
Mating Connector:
AMP 640250-6
Pins: 640252-2
Mating Connector:
Molex 190020001
Data Sheet © 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
LB130S56K REV 1.9 15-APRIL-14