Space saving with scoop proof connector for harsh and EMI applications.
A compact solution
Diameter up to 45% smaller than D38999 size 9.
Integrated backshell: up to 50% shorter.
A high density solution
With #26 contacts (according 39029).
6 layouts (size 3, 5 and 7 with #22 & #26).
Excellent features
Designed for D38999 requirements.
IP67 sealing when mated.
Ballseal (EMI).
RoHS and Cadmium free
Available in zinc nickel (RoHS) plating, as well
as nickel and olive drab cadmium.
Not QPL listed.
8BA Series
|
Break Away
Description
• A compact solution
- The smallest connector available on the
market (shell size 3)
- Break away: quick disconnect
- Integrated backshell:
. Easy to wire and handle
. Compatible with heat shrink boot and
braid retention band
. Compliant with overmolding
• A versatile solution
- 3 shells sizes: 3, 5, 7
- Plug; In line and jam nut receptacle
- Crimp & PC tails contacts (on request)
- Removable contacts #22D & #26
- 6 keyings
• Harsh environment-resistant solution
- Scoop Proof (when sockets mounted into
receptacle only)
- Cavity to cavity sealed with interfacial seal
and grommet
- Fluid resistant
Technical features
Mechanical
• Shell:
Aluminum alloy
• Shell plating:
Aluminum:
. Zinc nickel (RoHS)
. Nickel (RoHS)
. Olive drab cadmium
• Insulator:
Thermoplastic
• Contact body:
Copper alloy
• Contacts plating:
Gold over nickel plated
• Shell endurance:
Aluminum:
500 mating/unmating cycles
• Vibration:
30 grms ambiant, 2 axes during 8 hours
• Shock:
300g, 3 ms
Electrical
• Wire size
Layouts
03-05; 05-06;
07-09
03-35; 05-35;
07-35
Wire (AWG)
24-30
22-28
Environmental
• Temperature range:
-55°C to +175°C
• Water immersion:
IP 67 on mated connector
1 meter for 30 min minimum
> IP68 with appropriate cable termination
• Salt spray:
Zinc nickel: 500 hours
Nickel: 48 hours
Olive drab cadmium: 500 hours
• Test voltage (at sea level):
Size 22D: 1000 Vrms
Size 26: 400 Vrms
• Contact resistance:
Size 22D: <14.6 mΩ
• Contact rating:
Size 22D: 5A
Size 26: <16 mΩ
Resistance to fluids
• According to MIL-DTL-38999 standard
Gasoline: JP5 (OTAN F44)
Mineral hydraulic fluid: MIL-H-5606
(OTAN H515)
Synthetic hydraulic fluid: Skydrol 500 B4
• Compatible with de-icing fluids containing
potassium acetate
Size 26: 3A
• Contact retention:
Size 22D: 45N Size 26: 30N
• Shell to shell continuity (typical value)
Shell
size
3
5
7
Aluminum
version
10 mΩ
• EMI:
Aluminum: -70dB @ 1GHz
2
8BA Series
|
Break Away
Shell types
Plug
For other configuration or PC tail version, please consult us.
In line receptacle
Jam nut receptacle
Contact layouts
03
05
35
05
06
35
07
09
35
Size 3: Marking on shell.
Rear view of receptacle for male and
female insulator.
Opposite marking between plug and
receptacle.
Sizes 5 and 7: Marking on insulator.
Rear view of male insulator for plug
and receptacle.
Opposite marking between male and
female insulator.
5#26
3#22D
6#26
3#22D
9#26
5#22D
Ordering information
Basic Series
Shell type:
1:
In line receptacle
6:
Plug
7:
Jam nut receptacle
Shell size: 03, 05, 07
Plating :
Z:
Black zinc nickel
F:
Nickel
W:
Olive drab cadmium
Contact layouts:
See above
Contact type:
P:
Pin
S:
Socket (Scoop proof only when socket contacts mounted in Type 1 & Type 7)
Orientation: N, A, B, C, D, E
(see page 5)
8BA
1
03
W
05
P
N
3
8BA Series
|
Break Away
Dimensions
Plug - Shell type 6
B
B
Shell
size
D
A
A
D
3
5
C
Shell size 3 & 5
Shell size 7
C
7
A
10.3
12.2
14.3
B Max
18.4
19.4
24
C Max ØD Max
6.1
6.1
6.1
7.3
8.9
10
In line receptacle - Shell type 1
B
Shell size
3
A
D
5
7
C
A
11
12.8
14.3
B Max
17.7
19.1
24
C Max ØD Max
6.1
6.1
6.1
7.3
9
10
Jam nut receptacle - Shell type 7
B
D
B
D
G
A
A
F
F
H
E
C
Thread
Panel
thickness
Thread
E
C
Panel
thickness
Shell size 3
Shell size
3
5
7
Thread
7/16’’28 UNEF 2A
1/2’’28 UNEF 2A
9/16’’24 UNEF 2A
A Max
10.55
12.2
13.6
Shell size 5 & 7
B Max
17.7
22.5
24
C Max
3.2
3.2
3.2
D
1.75
±0.3
1.75
±0.3
1.75
±0.3
E Max ØF Max ØG Max
6.1
6.1
6.1
7.3
8.9
10
17.5
19.5
21
ØH
Panel cut out
J
11.3
±0.1
10.6
±0.05
12.8
±0.1
12.3
±0.05
14.5
±0.1
13.8
±0.05
Note: All dimensions are in millimeters (mm)
J
4
8BA Series
|
Break Away
Orientations
Shell size 3
Master Key
Shell sizes 5 & 7
Master Key
X°
Y°
Shell
size
3
5&7
Angles
X°
Y°
Z°
N
153
145
75
A
51
130
120
B
102
110
120
C
204
155
115
D
255
90
115
E
306
90
180
Z°
Viewed from front face of plug
Connector weights
Aluminum version -
in gram ±10 %
Shell size
& layout
3-05
5-06
7-09
Plug
Without contacts
1.7
2.6
4.3
With crimp contacts
1.8
2.8
4.7
In line receptacle
Without contacts
1.3
2.9
4.7
With crimp contacts
1.4
3.1
5.1
For further information contact us at
contactmilaero@souriau.com
or visit our web site
www.souriau.com
5
All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing.
I have always admired analog circuit design, so I learned a lot, but now that I have graduated, I regret not studying hard when I was in school. So I plan to learn it by myself.
Now I can do some basi...
TInergy is an energy community where people believe that technological innovation makes every aspect of life more efficient and is a bridge to clean, low-cost and renewable energy.As a member of the c...
The ARM Cortex-M0 processor is the smallest, lowest power 32-bit ARM processor on the market. With its extremely low power consumption, low gate count and small code resource footprint, this processor...
The fixed attenuator is made of color ring resistors, the attenuator is 40dB, the characteristic impedance is 50 ohms, and the π-type attenuator structure is used. After 1M, the output becomes very la...
The intelligent driving community has its own rhythm. Some are busy pushing new versions and focusing on R&D, others are busy with publicity and promotion, and still others are immersed in mass pro...[Details]
Some time ago, I attended the 4th Energy Chemistry Forum of the Chinese Chemical Society and learned about high-energy-density and high-safety batteries. I would like to summarize and share this wi...[Details]
New energy vehicles are increasingly popular with consumers due to policies and energy conservation. Once you've purchased your vehicle, maintenance is essential. However, due to the different powe...[Details]
Capable of providing precise and efficient thermal management for artificial intelligence computing power, intelligent sensing and autonomous driving systems
Shenzhen, ...[Details]
1 Introduction
In the mid-1960s, American scientist Maas conducted extensive experimental research on the charging process of open-cell batteries and proposed an acceptable charging curve for ...[Details]
The digital TV set-top box consists of a tuner, QAM demodulator, TS demultiplexer, MPEG-2 decoder, PAUNTSC video encoder, embedded CPU system and peripheral interfaces, CA module, and uplink data m...[Details]
A human-machine interface (HMI) refers to the platform used by people to operate a PLC. This platform provides an interface between programs and humans, serving as a medium for information transmis...[Details]
On August 22, the Wall Street Journal reported on the 21st local time that the new US government does not plan to acquire equity in semiconductor wafer foundry giant TSMC and Micron, one of the thr...[Details]
With the gradual popularization of new energy vehicles in recent years, more and more people have been able to access and purchase electric vehicles. The structure of electric vehicles is composed ...[Details]
Recently, UBTECH announced its patent for "robot self-battery replacement structure, device and method".
The Qichacha patent abstract shows that the robot's self-battery replacement stru...[Details]
Vision is the most sensitive and direct way for humans to perceive things. It allows us to acquire a wealth of information about our surroundings without physical contact. However, due to the compl...[Details]
PLC is the foundation of modern industry. Although it is a product of the Second Industrial Revolution, it has experienced nearly a century of ups and downs. Not only has it not disappeared, but it...[Details]
Industrial equipment plays a significant role in improving industrial automation and accelerating production efficiency. Industrial HMIs (Human-Machine Interfaces) serve as a communication platform...[Details]
The basic structure of the power grid dispatching automation system includes three parts: control center, master station system, plant terminal (RTU) and information channel. According to the diffe...[Details]
Silicon carbide (SiC) power switching devices are becoming a popular choice for industrial battery applications due to their ability to achieve faster switching speeds and superior low-loss operati...[Details]