EEWORLDEEWORLDEEWORLD

Part Number

Search

RPV5080MR301A410100

Description
Absolute Magnetostrictive Sensor, 50mm Min, 5080mm Max, 4-20mA
CategoryThe sensor   
File Size522KB,10 Pages
ManufacturerMTS Sensors
Websitehttps://www.mtssensors.com
Download Datasheet Parametric View All

RPV5080MR301A410100 Overview

Absolute Magnetostrictive Sensor, 50mm Min, 5080mm Max, 4-20mA

RPV5080MR301A410100 Parametric

Parameter NameAttribute value
MakerMTS Sensors
Reach Compliance Codeunknow
Other features1 TO 30 METERS CABLE, NON CONTACT, IP65
body width45 mm
body height75 mm
Body length or diameter49 mm
shellALUMINIUM
Linearity(%)0.01 %
Maximum measuring range (mm)5080 mm
Minimum measuring range (mm)50 mm
Maximum operating temperature75 °C
Minimum operating temperature-40 °C
Output range4-20mA
Output typeANALOG CURRENT
Repeatability0.001
resolution1 µm
Response time0.005 µs
Sensor/temperature sensor typeLINEAR POSITION SENSOR,MAGNETOSTRICTIVE,ABSOLUTE
Maximum supply voltage28.8 V
Minimum supply voltage19.2 V
Termination typeCABLE
Temposonics
®
Magnetostrictive Linear-Position Sensors
R-Series Model RP and RH Sensors - Analog Output
Position, Speed, Speed with Direction
Single or Dual Magnet Positions
Product Specification
R
SENSORS
550992 D
I
Rugged industrial sensor
I
Linear, absolute measurement
I
LEDs for sensor diagnostics
I
Non-contact sensing technology
I
Non-linearity less than 0.01%
I
Repeatability within 0.001%
I
Direct Analog output,
displacement + speed
I
Dual magnet position measurement
I
100% field adjustable Null and Span setpoints
The benefits of magnetostrictive sensing
Temposonics linear sensors use
the time-based magnetostrictive
position sensing principle devel-
oped by MTS. Within the sensing
element, a sonic strain pulse is
induced in a specially designed
magnetostrictive waveguide by
the momentary interaction of two
magnetic fields. One field comes
from a movable permanent
magnet that passes along the
outside of the sensor. The other
field comes from an “interroga-
tion” current pulse applied along
the waveguide. The resulting
strain pulse travels at ultrasonic
speed along the waveguide and is
detected at the head of the
sensing element. The position of
the magnet is determined with
high precision and speed by
accurately measuring the elapsed
time between the application of
the interrogation pulse and the
arrival of the resulting strain
pulse with a high speed counter.
Using the elapsed time to deter-
mine position of the permanent
magnet provides an absolute
position reading that never needs
recalibration or re-homing after a
power loss. Non-contact sensing
eliminates wear, and guarantees
the best durability and output
repeatability.
R-Series linear-position sensors
• R-Series model RH and RP sensors are extremely robust and are
ideal for continuous operation under harsh industrial conditions.
• Two standard sensor housings are available. The rod housing is
capable of withstanding high pressures such as those found in
hydraulic cylinders. The profile extrusion housing provides
convenient mounting options and sliding magnets.
• The sensor head contains the active signal conditioning and a
complete integrated electronics interface. Double shielding is used
to ensure EMI protection for unsurpassed reliability and
operating safety.
All specifications are subject to change. Please contact MTS for specifications that are critical
to your needs.
Technical guidance: What is the difference between lead-spray tin and lead-free tin spray on the pads on the PCB?
[align=left]The process requirements in the production of circuit boards are a very important factor, which directly determines the quality and positioning of a board. [/align][align=left]For example,...
szjlczhang PCB Design
Smart warehouse based on Gizwits AIoT development platform
[i=s]This post was last edited by Maoqiu Dada on 2021-12-15 19:25[/i]By analyzing the functions of traditional warehouses, we designed a system with STM32 as the main control chip, which is used in co...
毛球大大 RF/Wirelessly
[RT-Thread Reading Notes] Part 2 (5) Interrupt Management and Bidirectional Linked List
[align=left]The RTT system uses interrupts in the same way as the bare metal system does, but the interrupts can be associated with system threads with the help of the operating system's kernel IPC co...
我爱下载 Real-time operating system RTOS
How to change the display resolution of DE1-SoC?
The DE1-SoC board is connected to an external LCD monitor, keyboard and mouse via VGA; the official Linux_console_with_FrameBuffer is installed. There is only one resolution of 1024x768, and the best ...
cncqzxj FPGA/CPLD
Heroes from all walks of life, please help me with the tcpmp sample problem!
I compiled the sample of TCPMP into sample.exe and copied it together with common.dll and other components (decoder, language pack) to the same folder and downloaded it to the SD card of a navigation ...
wisper Embedded System
Analysis of the three major architectural elements of RF signal sources
Engineers are familiar with RF signal sources, which are often used to calibrate spectrum analyzers, modulation analyzers, power meters, frequency meters, RF millivolt meters, high-frequency digital o...
博宇讯铭 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2517  2427  1035  1355  1412  51  49  21  28  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190