Document 713-1
Coupled Inductors – LPR4012
For Step-Up, Resonant
& Flyback Applications
The LPR4012 miniature shielded coupled inductors are
only 1,1 mm high and 4 mm square. The excellent coupling
coefficient (k = 0.95) makes them ideal for use as flyback
transformers in DC-DC converters or as coupled inductors
in buck regulators to provide multiple outputs. The wide
selection of turns ratios makes them suitable for a variety
of voltage step-up and step-down applications. They can
also be used in autotransformer applications.
The high
Isat
and low DCR ratings of these low profile
parts provide high efficiency and excellent current handling
in a rugged, low cost design.
Custom inductance values and turn ratios are available
upon request.
Part number
1
LPR4012-202AMR_
LPR4012-202BMR_
LPR4012-202DMR_
LPR4012-202LMR_
LPR4012-103BMR_
LPR4012-103DMR_
LPR4012-223BMR_
LPR4012-223DMR_
Primary (L1)
inductance
2
± 20% (µH)
2.0
2.0
2.0
2.0
10.0
10.0
22.0
22.0
Turns
ratio
1
:
1.5
1
:
2
1
:
3
1
:
10
1
:
2
1
:
3
1
:
2
1
:
3
DCR max (Ohms)
L1
L2
0.240
0.240
0.240
0.240
0.600
0.600
1.16
1.16
0.325
0.480
1.15
11.62
1.55
3.71
3.65
7.08
SRF
typ
3
(MHz)
61.5
49.4
31.0
7.43
19.5
12.8
11.2
8.00
Isat
(A)
4
10% drop 20% drop 30% drop
1.70
1.70
1.70
1.70
0.62
0.62
0.43
0.43
1.73
1.73
1.73
1.73
0.64
0.64
0.45
0.45
1.74
1.74
1.74
1.74
0.65
0.65
0.46
0.46
Irms
(A)
5
20°C rise 40°C rise
1.10
1.10
1.10
1.10
0.52
0.52
0.43
0.43
1.45
1.45
1.45
1.45
0.70
0.70
0.57
0.57
1. When ordering, please specify
termination
and
packaging
codes:
LPR4012-223XMRC
Termination: R
= RoHS compliant matte tin over nickel over silver.
Special order:
Q
= RoHS tin-silver-copper (95.5/4/0.5) or
P
= non-RoHS tin-lead (63/37).
Packaging: C
= 7″ machine-ready reel. EIA-481 embossed plastic tape (1000 parts per full reel).
B
= Less than full reel. In tape, but not machine ready. To have a leader and trailer added ($25 charge), use code letter D instead.
D
= 13″ machine-ready reel. EIA-481 embossed plastic tape. Factory order only, not stocked (3500 parts per full reel).
2. Inductance is measured at 100 kHz, 0.1 Vrms, 0 Adc on an Agilent/HP 4284A LCR meter or equivalent.
3. SRF measured using an Agilent/HP 4191A or equivalent. When leads are connected in parallel, SRF is the same value.
4. DC current at 25°C applied to L1 that causes the specified inductance drop from its value without current.
5. Current applied to L1 that causes the specified temperature rise from 25°C ambient. This information is for reference only and does not represent absolute
maximum ratings.
Refer to Doc 362 “Soldering Surface Mount Components” before soldering.
US
+1-847-639-6400 sales@coilcraft.com
UK
+44-1236-730595 sales@coilcraft-europe.com
Taiwan
+886-2-2264 3646 sales@coilcraft.com.tw
China
+86-21-6218 8074 sales@coilcraft.com.cn
Singapore
+ 65-6484 8412 sales@coilcraft.com.sg
Document 713-1
Revised 08/25/16
© Coilcraft Inc. 2016
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.
Document 713-2
Coupled Inductors – LPR4012 Series
D
+
C
V
OUT
AUX
L2
+
V
IN
SW
–
+
L1
D
C
V
OUT
–
–
Typical Buck Converter with auxiliary output
+
D
+
L1
L2
C
V
OUT
V
IN
C
PWM
–
Core material
Ferrite
Weight
54 – 64 mg
Terminations
RoHS compliant matte tin over nickel over silver. Other
terminations available at additional cost.
Ambient temperature
–40°C to +85°C with
Irms
current
Maximum part temperature
+125°C (ambient + temp rise)
Storage temperature
Component: –40°C to +125°C.
Tape and reel packaging: –40°C to +80°C
Winding to winding isolation
100 V
Resistance to soldering heat
Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Moisture Sensitivity Level (MSL)
1 (unlimited floor life at <30°C /
85% relative humidity)
Mean Time Between Failures (MTBF)
26,315,789 hours
Failures in Time (FIT)
38 per one billion hours
Packaging
1000/7″ reel; 3500/13″ reel Plastic tape: 12 mm wide,
0.25 mm thick, 8 mm pocket spacing, 1.32 mm pocket depth
Recommended pick and place nozzle
OD: 4 mm; ID:
≤
2 mm
PCB washing
Tested to MIL-STD-202 Method 215 plus an additional
aqueous wash. See
Doc787_PCB_Washing.pdf.
–
Typical Flyback Converter
Dot indicates pin 1
1
4
1
0.155 ±0.003
*
3,94 ±0,076
L1
2
L2
4
2
XXXX
Dash
number
3
3
0.0433 ±0.004
*
1,10 ±0,10
0.155 ±0.003
*
3,94 ±0,076
Recommended
Land Pattern
1
4
0.103 0.049
2,606 1,24
2
0.031
0,78
45°
typ
0.174
4,40
3
0.060
1,52
of
*
Dimensions are Forthe case not including
the termination.
maximum overall
dimensions including the termination, add
0.005 in / 0,13 mm.
For optional tin-lead and tin-silver-copper
terminations, dimensions are for the
mounted part. Dimensions before mounting
can be an additional 0.005 inch / 0,13 mm).
0.049
1,24
0.103
2,606
0.174
4,40
Dimensions are in
inches
mm
US
+1-847-639-6400 sales@coilcraft.com
UK
+44-1236-730595 sales@coilcraft-europe.com
Taiwan
+886-2-2264 3646 sales@coilcraft.com.tw
China
+86-21-6218 8074 sales@coilcraft.com.cn
Singapore
+ 65-6484 8412 sales@coilcraft.com.sg
Document 713-2
Revised 08/25/16
© Coilcraft Inc. 2016
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.