and One-Stage and Two-Stage and One-Stage and Two-Stage
Isolator
Isolator
Isolator
Isolator
Signal central wavelength,
λ
C
Signal wavelength range,
λ
S
Pump channel
wavelength range,
λ
P
Port configuration
Insertion loss at
λ
S
(note
3
)
Max.
Wavelength dependent
Max.
variation at
λ
S
and
C, L, or S bands (note
3
)
Wavelength dependent
Max.
variation at
λ
S
and
C+L band (note
3
)
PDL at
λ
S
(note
3
)
Max.
3
PMD at
λ
S
(note )
Max.
Isolation of isolator
Min.
4
at
λ
S
(note )
Isolation of WDM
Min.
5
at
λ
P
(note )
Insertion loss (C to R) at
λ
P
Max.
PDL (C to R) at
λ
P
Max.
Directivity (P to R) at
λ
S
Min.
Directivity (R to P) at
λ
P
Min.
Optical return loss
Min.
Maximum optical
power (standard)
Maximum optical power
(high power option)
Tensile load
Max.
Operating temperature
Storage temperature
Package dimensions (D x L)
Fiber type
Pigtail color code (bare fiber)
Pigtail color code (loose tube)
Device marking
C, L or 1
C, L or 1
C, L or 1
C, L or 1
(C=1550 nm, L=1590 nm, 1=1570 nm, S=1510 nm)
C, L or S
C, L or 1
C, L or 1
C, L or 1
C, L or 1
(C=1530 to 1580 nm, L=1590±20 nm, 1=C+L=1530 to 1610nm, S=1490 to 1530 nm)
N/A
1465 to 1495 nm 1465 to 1495 nm 950 to 1010 nm
950 to 1010 nm
Backward
(note
1
)
Forward or
backward
(note
2
)
0.6 dB
0.2 dB
Forward or
backward
(note
2
)
0.6 dB
0.15 dB
Forward or
backward
(note
2
)
0.7 dB
0.2 dB
Forward or
backward
(note
2
)
See table on page 2 See table on page 2 0.5 dB
0.2 dB
0.2 dB
0.15 dB
NA
NA
0.25 dB
0.3 dB
0.25 dB
0.3 dB
0.1 dB
0.05 ps
30 dB
N/A
See table on page 2
0.05 dB
60 dB
N/A
50 dB
500 mW
2000 mW
5N
0.2 dB
0.05 ps
42 dB
N/A
See table on page 2
0.05 dB
60 dB
N/A
50 dB
500 mW
2000 mW
5N
0.06 dB
0.05 ps
30 dB
30 dB
0.4 dB
0.05 dB
60 dB
60 dB
50 dB
500 mW
2000 mW
5N
0.08 dB
0.05 ps
45 dB
30 dB
0.4 dB
0.05 dB
60 dB
60 dB
50 dB
500 mW
2000 mW
0.06 dB
0.05 ps
30 dB
30 dB
0.6 dB
0.1 dB
60 dB
60 dB
50 dB
150 mW
450 mW
0.08 dB
0.05 ps
45 dB
30 dB
0.6 dB
0.1 dB
60 dB
60 dB
50 dB
150 mW
450 mW
5N
5N
5N
-5 to 70 °C
-40 to 85 °C
5.5 mm x 32 mm for bare fiber and 5.5 mm x 40 mm for bare fiber or loose tube
PureMode Hi 1060 for ports transmitting 980 nm (standard), SMF-28 for all others (standard)
Black (C port); Clear (R & P ports)
Red (C port); Blue (R & P ports)
JDSU logo, JDSU model name and device serial number
Note: Parameters are specified for the signal wavelength range and/or pump wavelength range, all polarization states and operating temperature range without connector.
1
2.
3.
4.
5.
Backward tap: C (input), R (tap) and P (output).
Backward pumped: C (λ
S
input and
λ
P
output), R (λ
P
input) and P (λ
S
output). Forward pumped: C (λ
S
and
λ
P
output), R (λ
P
input) and P (λ
S
input).
Forward: P to C and Backward: C to P.
Forward: C to P and Backward: P to C. The isolation data are specified at 23 °C. The isolation range is
λc
± 12 nm or
λc
± 30 nm for one-stage or two-stage isolator, respectively.
Isolation of WDM is given for both C to P and P to C directions.
AHC SERIES
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at
customer.service@jdsu.com.
Sample: AHC-C30R10000
AHC-
Code
C
L
S
1
Signal Wavelength
C-band
L-band
S-band
C+L-bands
Code
J
K
N
Code
0
3
5
Pump Wavelength
No pump option
1480
nm
980
nm
Q
R
S
Code
0
1
2
3
4
5
A
T
Tap Ratio
No
tap
option
1%
2%
3%
4%
5%
1.8%
10%
V
Z
Isolator, Pump Configuration,
Package Length
One-stage, forward-pumped,
32 mm (L)
One-stage, forward-pumped,
40 mm (L)
One-stage, backward-pumped or
tap,
32 mm (L)
One-stage, backward-pumped or
tap,
40 mm (L)
Two-stage, forward-pumped,
40 mm (L)
Two-stage, forward-pumped,
32 mm (L)
Two-stage, backward-pumped
(or
tap),
40 mm (L)
Two-stage, backward-pumped
(or
tap),
32 mm (L)
Code
1
2
4
5
Fiber Pigtail Length
1 meter
2 meters
0.5 meter
1.5 meters
0
Code
0
1
2
3
4
5
8
9
A
B
C
Connectors
No
connector
FC/PC
FC/SPC
FC/APC
SC/SPC
SC/APC
ST
FC/UPC
SC/UPC
LC/SPC
LC/UPC
Code
0
1
Fiber Buffer Type
250 µm bare fiber
900 µm loose
tube
Code
0
H
Power Handling Option
Standard:
150 mW at
980
nm
and 500 mW for
all others
High
Power:
450 mW at
980
nm
and 2000 mW
for all others
Note: Other configuratons and wavelengths are available on custom basis.
SMF-28 and PureMode are registered trademarks of Corning Incorporated.
ST and LC are registered trademarks of Lucent Technologies.
All statements, technical information and recommendations related to the products herein are based upon information believed to be
reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any
inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves
the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, including
withdrawal at any time of a product offered for sale herein. JDSU makes no representations that the products
herein are free from any intellectual property claims of others. Please contact JDSU for more information. JDSU and the JDSU logo are
I want to make a slider control to control the magnification of the picture, divided into 4 grids, only four grids, that is, no matter whether the mouse is moved or clicked, it only needs to be in the...
[align=center][backcolor=rgb(255, 255, 255)][size=5]Perception of Design[font=Microsoft YaHei]-[/font][font=宋体]Experience and Philosophy of Electronic Design[/font][/size][/backcolor][/align][align=le...
I don't know anything about radio technology, so I would like to ask some basic questions.
First, can the Zigbee chip be made very small?Second, can the Zigbee transmission distance be changed accordi...
Sharing of household heating and cooling inverter air conditioner application solutions based on MM32SPIN series MCU : https://training.eeworld.com.cn/course/5661Introduction to variable frequency air...
Sailing is gaining more and more attention. How to use modern technology to assist training and improve competition results is particularly important. Considering the real-time data collection in t...[Details]
1 Introduction
A wide variety of communication cables and control cables are widely used in various instruments and control equipment. Whether the cable is well-conducted and
whether
th...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
In the previous series, we have listed some basic knowledge of C language in Tables 1 to 3. We hope that beginners can strengthen their memory of the above tables and gradually learn to use them wh...[Details]
5. Identifiers and keywords of C language
A complete PIC microcontroller C language program usually consists of six parts: include files (i.e. header files 1, variable definitions, variable de...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
1 Introduction
Intelligent control instruments are one of the most commonly used controllers in industrial control. They are mainly aimed at a specific parameter (such as pressure, tempera...[Details]
MediaTek (2454) announced the acquisition of F-MStar (3697) and attracted the attention of IC design industry. This morning, Gartner Semiconductor Industry Research Director Hong Cenwei analyzed ...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
Abstract: In recent years, with the establishment and grid-connected power generation of a large number of solar photovoltaic power stations at home and abroad, photovoltaic grid-connected inverter...[Details]
With the widespread application of new services and technologies in the communications industry, the scale and capacity of operators' network construction are getting larger and larger, and the ris...[Details]
Only a small number of LED manufacturers can produce high-quality LEDs. For applications that are only used for simple indication, low-quality LEDs are sufficient. However, high-quality LEDs must...[Details]