TN2-12

Description
POWER/SIGNAL RELAY, DPDT, LATCHED, 0.008A (COIL), 12VDC (COIL), 100mW (COIL), 1A (CONTACT), 110VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size75KB,4 Pages
ManufacturerNais ( Matsushita Electric Works )
Websitehttp://www.nais-e.com/
Download Datasheet Parametric Compare View All

TN2-12 Overview

POWER/SIGNAL RELAY, DPDT, LATCHED, 0.008A (COIL), 12VDC (COIL), 100mW (COIL), 1A (CONTACT), 110VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT

TN2-12 Parametric

Parameter NameAttribute value
Maximum operating temperature70 Cel
Minimum operating temperature-40 Cel
Processing package descriptionROHS COMPLIANT
Lead-freeYes
EU RoHS regulationsYes
stateEOL/LIFEBUY
Coil power100 mW
Relay actionlocking
Relay functionDouble Knife Double Throw
Coil resistance1440 ohm
Electrical life100000 Cycle(s)
terminal coatingNOT SPECIFIED
Manufacturer SeriesTN
Maximum DC coil current0.0080 A
Maximum DC coil voltage12 V
Maximum AC contact current1 A
Maximum DC contact current1 A
Maximum AC contact voltage125 V
Maximum DC contact voltage110 V
DC coil operating voltage9 V
DC coil release voltage9 V
width5.6 mm
high9.8 mm
length or diameter14 mm
Installation featuresThrough hole installation
operating hours3 ms
Relay typePOWER/SIGNAL RELAY
release time3 ms
Terminal typewelding
SLIM POLARIZED RELAY
TN-RELAYS
• Surge voltage withstand: 1500 V FCC
Part 68
• Sealed construction allows automatic
cleaning
• Self-clinching terminal also available
14
.551
5.6
.220
9.8
.386
FEATURES
• Small size for minimal PC board
mounting requirements
• Small header area makes higher den-
sity mounting possible
• High sensitivity: 140 mW nominal op-
erating power (single side stable 3-12
V type)
mm
inch
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Contact material
Nominal switching capacity
(resistive load)
Max. switching power
(resistive load)
Rating
Max. switching voltage
Max. switching current
Min. switching capacity
f
1
Single side stable
Nominal
operating
power
1 coil latching
2 coil latching
Mechanical (at 180 cpm)
1 A 30 V DC
resistive load
Electrical
(at 20 cpm) 0.5 A 125 V AC
resistive load
2 Form C
60 m
Gold-clad silver
1 A 30 V DC,
0.5 A 125 V AC
30 W, 62.5 VA
110 V DC,125 V AC
1A
10
µ
A 10 mV DC
140 mW (3 to 12 V DC)
200 mW (24 V DC)
300 mW (48 V DC)
100 mW (3 to 12 V DC)
150 mW (24 V DC)
200 mW (3 to 12 V DC)
300 mW (24 V DC)
10
8
2
×
10
5
10
5
Initial
breakdown
voltage
Characteristics
Initial insulation resistance*
1
Between open
contacts
Between contact and
coil
Between contact sets
FCC surge voltage between open
contacts
Temperature rise*
2
(at 20
°
C)
Operate time [Set time]*
3
(at 20
°
C)
Release time [Reset time]*
4
(at 20
°
C)
Shock resistance
Functional*
5
Destructive*
6
Functional*
7
Vibration resistance
Destructive
Conditions for oper-
ation, transport and
storage*
8
(Not freezing and
condensing at low
temperature)
Unit weight
Ambient
temperature
Humidity
Max. 3
[Max. 3
Max. 3
[Max. 3
Min. 1,000 M
(at 500 V DC)
750 Vrms for 1 min.
(Detection current: 10 mA)
1,000 Vrms for 1 min.
(Detection current: 10 mA)
1,000 Vrms for 1 min.
(Detection current: 10 mA)
1,500 V
Max. 50
°
C
ms (Approx. 2
ms (Approx. 2
ms (Approx. 1
ms (Approx. 2
ms)
ms)]
ms)
ms)]
Min. 490 m/s
2
{50G}
Min. 980 m/s
2
{100G}
176.4 m/s
2
{18G}, 10 to 55 Hz
at double amplitude of 3 mm
294 m/s
2
{30G}, 10 to 55 Hz
at double amplitude of 5 mm
–40
°
C to +70
°
C
–40
°
F to +158
°
F
5 to 85% R.H.
Approx. 1.5 g .053
oz
Expected
life (min.
operations)
Note:
f
1This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the ac-
tual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
Nominal voltage applied to the coil, excluding contact bounce time without diode.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10
µ
s.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10
µ
s.
*
8
Refer to 4. Conditions for operation, transport and storage mentioned in Cautions
for use (Page 178).
ORDERING INFORMATION
Ex. TN
2
L2
H
12V
Contact arrangement
2: 2 Form C
Operating function
Nil: Single side stable
L: 1 coil latching
L2: 2 coil latching
Terminal shape
Nil: Standard PC board terminal
H: Self-clinching terminal
Coil voltage(DC)
3,4.5,5,6,9,12,
24,48*V
*48 V coil type: Single side stable only
Note: AgPd stationary contact types available for high resistance against contact sticking.
When ordering, please add suffix “–3” like TN2–12V–3.
150

TN2-12 Related Products

TN2-12 TN2-L-H-4V TN2-L2-H-4V
Description POWER/SIGNAL RELAY, DPDT, LATCHED, 0.008A (COIL), 12VDC (COIL), 100mW (COIL), 1A (CONTACT), 110VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT SLIM POLARIZED RELAY SLIM POLARIZED RELAY
What does it mean that T5500 does not support virtualization technology?
Does T5500 not support virtual technology mean that it does not support VMWEAR virtual machines, etc., and cannot install LINUX, VISTA, JAVA virtual machines, etc. Or are CPU virtual technology and vi...
像见 Embedded System
MSP430F149-SHT15 sensor routine (call at any time, with comments)
[size=4]MSP430F149-SHT15 sensor routine (call at any time, with comments)[/size] [size=4][/size]...
Jacktang Microcontroller MCU
Help, IAR FOR 430 defined variables are modified
I defined a variable in a file with an initial value of 130, declared it as an extern variable in a header file, included the header file in another file, and then displayed the variable. I found that...
175924605 Microcontroller MCU
Why is the serial port sending data incorrect?
When only one data is sent, the data is correct, but when the data is sent continuously in the query mode, the data is wrong. Moreover, when judging whether the data end code is received, the query mo...
wuaiabab MCU
Getting a task done in another clock domain
If the clkA domain has a task that needs to be completed in the clkB domain, you can use the following design. [img]http://www.fpga4fun.com/images/CrossClockDomain.task.gif[/img] Here's one way to do ...
eeleader FPGA/CPLD
The latest embedded design textbook published in 2008, share the first two
Just got a new book, published in 2008...
besk Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1179  1621  793  2544  2887  24  33  16  52  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号