* Code C, MIL-C-22992, Left-Hand Thread. Connector designations depicted thus [ ] are for reference only and are not to be used in part number development.
BACKSHELL INTERFACE STANDARDS (See pages 15-17 for more information)
DESIG. SPEC.
SERIES
DESIG. SPEC.
SERIES
A
MIL-DTL-5015 MS3400
A
PATT 602
MIL-DTL-26482 2
B
MIL-DTL-5015 MS3100
AS81703
3
C
MIL-C-22992 MS173XX
MIL-DTL-83723 I & III
D
MIL-DTL-26482 1
40M39569
E
MIL-DTL-26500 Aluminum
DEF 5326-3
F
MIL-DTL-38999 I & II
EN 2997, 3646
40M38277
ESC 10, 11
PAN 6433-1
LN 29504
PATT 614
NFC93422 HE302
PATT 616
PAN 6432-1, -2
NFC93422
HE308, 9
DESIG. SPEC.
SERIES
G
MIL-C-28840
H
MIL-DTL-38999 III & IV
EN3645
J
MIL-C-81511 1, 2, 3 & 4
VG95329
K
MIL-DTL-83723 II
DESIG. SPEC.
L
EN3372
JN 1003
LN 29729
NFC93422
PAN 6433-2
PATT 615
VG 96912
S
PATT 105
PATT 603
PATT 608
SERIES
HE306
13
How
to Order
CONNECTOR DESIGNATOR
A THREAD*
REFERENCE
7/16 – 28 UNEF
M12 x 1 – 6H
1/2 – 20 UNF
1/2 – 28 UNEF
9/16 – 24 UNEF
M15 x 1 – 6H
5/8 – 24 UNEF
5/8 – 28 UN
11/16 – 24 UNEF
M18 x 1 – 6H
3/4 – 20 UNEF
13/16 – 20 UNEF
M22 x 1 – 6H
7/8 – 20 UNEF
7/8 – 28 UN
15/16 – 20 UNEF
M25 x 1 – 6H
1 – 20 UNEF
1 - 28 UN
1 1/16 – 18 UNEF
M28 x 1 – 6H
1 1/8 – 18 UNEF
1 1/8 – 28 UN
1 3/16 – 18 UNEF
M31 x 1 – 6H
1 1/4 – 18 UNEF
1 1.4 – 28 UN
1 5/16 – 18 UNEF
M34 x 1 - 6H
1 3/8 – 18 UNEF
1 3/8 – 28 UN
1 7/16 – 18 UNEF
M37 x 1 – 6H
1 1/2 – 18 UNEF
1 1/2 – 28 UN
1 9/16 – UNEF
1 5/8 – UNEF
1 3/4 – 18 UNS
1 7/8 – 16 UN
2 – 18 UNS
2 1/16 – 16 UNS
2 1/8 – 16 UN
2 1/4 – 16 UN
2 5/16 – 16 UNS
2 3/8 – 16 UN
2 1/2 – 16 UN
2 5/8 – 16 UN
2 3/4 – 16 UN
2 7/8 – 16 UN
3 – 16 UN
3 1/16 – 16 UN
B
DIA MAX
.590 (15.)
.650 (16.5)
.650 (16.5)
.650 (16.5)
.720 (18.3)
.770 (19.6)
.770 (19.6)
.770 (19.6)
.840 (21.3)
.890 (22.6)
.970 (24.6)
.970 (24.6)
1.030 (26.2)
1.090 (27.7)
1.030 (26.2)
1.090 (27.7)
1.150 (29.2)
1.220 (29.2)
1.150 (29.2)
1.220 (31.0)
1.280 (32.5)
1.340 (34.0)
1.280 (32.5)
1.340 (34.0)
1.410 (35.8)
1.470 (37.3)
1.410 (35.8)
1.470 (37.3
1.530 (38.9)
1.590 (40.4)
1.530 (38.9)
1.590 (40.4)
1.660 (42.2)
1.660 (42.2)
1.660 (42.2)
C
DIA MAX
.650 (16.5)
.770 (19.6)
.650 (16.5)
.770 (19.6)
.770 (19.6)
.820 (20.8)
.770 (19.6)
.890 (22.6)
.890 (22.6)
.940 (23.9)
.940 (23.9)
1.020 (29.2)
1.070 (26.2)
1.020 (25.9)
1.150 (29.2)
1.150 (29.2)
1.210 (30.7)
1.210 (30.7)
1.360 (34.5)
1.230 (31.2)
1.360 (34.5)
1.360 (34.5)
1.480 (37.6)
1.360 (34.5
1.480 (37.6)
1.530 (38.9)
1.600 (40.6)
1.480 (37.6)
1.600 (40.6)
D
DIA MAX
.770 (19.6)
E
DIA MAX
.690 (17.5)
.940 (24.8)
.690 (17.5)
How
to Order
GLENAIR
SYMBOL
A
B
C*
G*
J
LF
M
N
NC
NF
T
U
ZU**
ZN
*
**
W
N
A
M85049 SYMBOL
REFERENCE ONLY
FINISH
Cadmium Plate, Bright
Anodize, Black
Hard Coat, Anodic
Electroless Nickel
Cadmium Plate, Black
Cadmium Plate, Black
Reference Information
Standard Materials and Finishes
TABLE II - STANDARD FINISHES
SPECIFICATION(S)
AMS-QQ-P-416, Type I, Class 2
AMS-QQ-P-416, Type II, Class 3
AMS-A-8625, Type II, Class 2
AMS-A-8625, Type III, Class 1
Cadmium Plate, Olive Drab
Iridite, Gold Over Cadmium Plate Over MIL-C-5541, Class 3 AMS-QQ-P-416, Type II,
Electroless Nickel
Class 3 over AMS-C-26074, Class 4, Grade B
Cadmium Plate, Bright Over
Electroless Nickel
Cadmium Plate, Olive Drab Over
Electroless Nickel
Zinc Cobalt, Dark Olive Drab
Cadmium Plate, Olive Drab Over
Electroless Nickel
Cadmium Plate, Bright Over
Electroless Nickel
1000 Hour Corrosion Resistance
AMS-C-26074, Class 4, Grade B
AMS-QQ-P-416, Type II, Class 3 over Electroless Nickel
AMS-C-26074
96 Hour Corrosion Resistance
1000 Hour Corrosion Resistance
AMS-QQ-P-416, Type I, Class 3
ASTMB 733-90, SC2, Type I, Class 5, MIL-C-26074***
AMS-QQ-P-416, Type II, Class 3
AMS-QQ-P-416, Type II, Class 3
ASTMB 841-91, Over Electroless Nickel 1000 Hour Salt
Spray
Zinc-Nickel Alloy, Olive Drab
Anodize finish; not suitable for EMI Shielding or grounding applications.
Applicable to corrosion resisting steel backshells and accessories. Consult factory for other available finishes.
The following standard materials are used for the majority of Glenair
backshells and connector accessories. However, backshell compo-
nents are not limited to those items listed, but are representative of
the elements used in Glenair's general accessory products. Contact
Glenair for applicable specifications on items not listed below.
STANDARD MATERIALS - BACKSHELLS AND ACCESSORIES
COMPONENT
Machined components: such as backshell bodies, fabricated elbows, protective covers,
rotatable couplers, dummy stowage receptacles, lock nuts, G-spring support rings,
EMI ground rings, grommet followers, etc.
Die cast components: such as angular backshells, strain relief backshells, strain relief
bodies, strain relief saddles, special EMI ground rings, etc.
Backshells or strain reliefs: available in optional corrosion resisting steel; and
hardware: such as screws, washers, rivets, wire rope, sash chain, band straps, etc.
Elastomeric seals: such as O-rings, cable jacket seals, grommets, etc.
Anti-friction and thrust washers
Anti-rotation device
MATERIAL
Aluminum
SPECIFICATION
AMS-QQ-A-200
ASTMB221, 209
QQ-A-591
ASTMB85, 26
Corrosion Resisting Steel ASTMA582 (300 Series)
AMS-QQ-S-763
Silicone
ZZ-R-765, MIL-R-25988
Teflon
TFE
N/A
Corrosion Resistant
Material
Aluminum
BODY STRAP
Glenair offers an optional stainless steel body strap for
attaching protective covers as illustrated. To specify body
strap, add suffix letter C to the end of the part number. For
example 360AS001M1610M6C.
NOTES
On all length callouts, tolerance is ± .060 unless otherwise
specified.
Unless otherwise specified, the following other dimensional
tolerances will apply:
.xx = ± .03 (0.8)
.xxx = ± .015 (0.4)
Lengths = ± .060 (1.52)
Angles = ± 5°
Metric dimensions (mm) are indicated in parentheses
This paper discusses the design of a basic feedback oscillator, using a lumped element resonator with varactor control. A design center frequency of 1GHz has been chosen, with a tuning bandwidth of 50...
[color=black]This switching power supply is a low-power switching power supply. It inputs 220V AC mains power and outputs 12V DC power. The maximum output current is 1.3A. It is mainly used to power s...
My teacher and I are designing a piezoelectric ceramic drive power supply, which requires a DC 120V voltage. Previously, a senior student used five 220V--24V transformers, then rectified and stabilize...
I am a novice, and I need to use evc to develop an application to operate the registers of the network card (the network card is dm9000a wince platform). Can I call the driver function directly or use...
A friend gave me two tickets for Avatar that night, so my family of three rushed over. My husband took my daughter to watch the movie, and we waited outside. There were so many people, the movie theat...
The power consumption of the code is different when it is executed in different flash or SRAM, but after searching for a long time, I still can't find how to configure the code execution to different ...
Calibrators are widely used in university experiments. Among them, there are two experiments in nuclear physics experiments in modern physics experiments (GM counter and β absorption) that require ...[Details]
Although improper medical device product design is not always associated with medical device-related errors. Studies of users have shown that lack of adequate training accounts for 70% to 90% of suc...[Details]
A ventilator is an instrument that can replace or assist a person's respiratory function. It is suitable for artificial respiration of patients with respiratory failure or even respiratory arrest. I...[Details]
Radio Frequency Identification (RFID) technology is a non-contact automatic identification technology that uses wireless radio frequency communication. Compared with the currently widely used barco...[Details]
For more than 10 years, analog-to-digital converters (ADCs) have been widely used in industrial process control, medical instruments, communication systems, radar and other products as a booster of in...[Details]
Implantable Cardivoerter Defibrillators (ICDs) have been in common use for several years. ICDs apply a high voltage pulse between two electrodes connected to the heart, which detects cardiac fibrillat...[Details]
As the application scope of medical equipment expands from hospitals to emergency response and home medical environments, its mobility will be determined by many factors. In addition, medical equip...[Details]
With the rapid development of computer technology, embedded image systems are widely used in office equipment, manufacturing and process design, medical, monitoring, sanitary equipment, transportat...[Details]
Emulation Features
Emulation provides a set of standard operations for integration and debugging. Some of its main features are as follows:
BreakpointsA
common feature of emulatio...[Details]
Over the past 15 to 20 years, automotive power MOSFETs have evolved from an initial technical topic to a thriving commercial sector. Power MOSFETs were chosen because they can withstand transient ...[Details]
Portable devices with audio functions (such as portable media players and multimedia mobile phones) require long audio playback time, that is, long battery life. To extend the battery life of port...[Details]
Lithium-ion batteries have a high energy-to-weight and energy-to-volume ratio, no memory effect, can be recharged many times, have a long service life, and are becoming increasingly cheaper. A good...[Details]
introduction
Mobile phones, MP3 players, hard disk players, digital cameras, PDAs and other devices are all controlled by navigation keys. Currently, the more popular navigation key contro...[Details]
At present, the IEEE802.11 wireless LAN standard is widely used in voice communication, wireless office and other fields, but it is still mainly limited to wireless communication on general platfor...[Details]
A correct circuit design cannot be manufactured 100% correctly when it is taken to the factory for manufacturing. It will always be affected by various uncertainties, such as deviations in manufact...[Details]