EEWORLDEEWORLDEEWORLD

Part Number

Search

HGN-365A01Q-10-1AS

Description
1A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET
Categorysemiconductor    Other integrated circuit (IC)   
File Size473KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Download Datasheet View All

HGN-365A01Q-10-1AS Overview

1A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET

HGN-365A
IEC 60320 INLET SOCKET WITH SINGLE OR DOUBLE FUSE HOLDER,
SNAP-IN OR FLANGE MOUNT
MECHANICAL DIMENSIONS
(Unit: mm)
SNAP-IN
30.8
28.3
28.5
31.0
33.0
35.0
32.3
Use only with a 250V Fuse
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
FEATURES
The HGN-365A filter series offers a wide variety of options
with a current rating up to 10A, 250VAC. This power entry
module offers industry standard 5 x 20mm fuse/s with IEC
connector. This series offers an option of having a single or
double fuse in the same package. These filters are also used
for health care equipment and offer extremely low leakage
current to comply with UL544 & 2602.
A Ground Choke can be added to enhance the grounding
ability of the circuit. A bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
2x
6
33.0
Use only with a 250V Fuse
42.6
48.5
(58.4)
6.3
27.8
31.0
FLANGE MOUNT
28.3
36.0
28.0 Max
31.0
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
2x
3.6
32.4 Typ.
2x
3.6
RECOMMENDED
PANEL CUTOUT
(MOUNTING FROM FRONT)
36.0
44.0
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 8A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA
@ 250VAC 50Hz: 1.0mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
Panel Thickness 1mm to 1.6mm
(58.4)
48.5
42.6
6.3
27.8
31.0
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
70
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
A question about MSP430F2132 interrupts?
Define a global variable FrequencyCounter for counting in the Timer0_A3 interrupt program. It's a very simple one, but there is a problem!unsigned int FrequencyCounter;main(){ ... ...}#pragma vector=T...
零晨 Microcontroller MCU
8-bit MCU development techniques and specifications He Zongbin
Introducing this book, um, I'll write the introduction after I finish reading it.There is no other place to download it on the Internet except CSDN. I will add this here so that you don’t have to worr...
辛昕 51mcu
Keep reading. Good book.
[i=s]This post was last edited by paulhyde on 2014-9-15 08:54[/i]Thumbs up! ! ! ! ! ! ! ! ! ! ! !! ! ! ! ! ! ! ! ! ! !...
xupeilinhong Electronics Design Contest
CSS software Chinese manual v2
...
cobble1 DSP and ARM Processors
The output of a 6V battery is less than 2V. Is it broken?
As the title says, please help me take a look....
fish001 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 282  1601  2805  1017  441  6  33  57  21  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号