EEWORLDEEWORLDEEWORLD

Part Number

Search

F.MF.06A.06.02.GC

Description
Mains Power Connector, 6A, 250VAC, Male, Solder Terminal
CategoryThe connector    The connector   
File Size718KB,3 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

F.MF.06A.06.02.GC Overview

Mains Power Connector, 6A, 250VAC, Male, Solder Terminal

F.MF.06A.06.02.GC Parametric

Parameter NameAttribute value
MakerKEMET
Reach Compliance Codecompli
Other featuresSTANDARDS: IEC 60320, CSA, UL, VDE
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSCREW
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings6A, 250VAC
Manufacturer's serial numberF.MF
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
IEC Inlet Filters
With fuse holders and voltage selectors
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus input voltage selector
with 4 possible combinations. These features ensure the range is
ideally suited for manufacturers of business, consumer and medical
equipment for international markets.
F.MF-F.MG
series
Current ratings from 1A to 6A
Integral single or twin fuse holder
Voltage selector
Snap-in or screw mount versions
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320, 1 (F.MF) or 2 (F.MG) fuse
holders for fuses 5 x 20mm (IEC) or 6.3 x 32mm
(US), voltage selector with 4 possible combinations;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 2.8 x 0.5mm for voltage selector terminals;
ground terminal connected to case.
F.MF.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 2500
F.MG. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MF.01A.01.01.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Voltage selector:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
110-220-240Vac
100-120-220-240Vac
115-115-230-230Vac
110-220Vac
Leakage current (I
L
):
at 220V, 50Hz, max value
F = 1 fuse
G = 2 fuses
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
01 = fuse 5 x 20mm + voltage selector 110-220-240V~
02 = fuse 5 x 20mm + voltage selector 100-120-220-240V~
03 = fuse 5 x 20mm + voltage selector 115-115-230-230V~
08 = fuse 6.3 x 32mm + voltage selector 110-220-240V~
09 = fuse 6.3 x 32mm + voltage selector 100-120-220-240V~
10 = fuse 6.3 x 32mm + voltage selector 115-115-230-230V~
15 = fuse 5 x 20mm + voltage selector 110-220V~
16 = fuse 6.3 x 32mm + voltage selector 110-220V~
19 = fuse 5 x 20mm + voltage selector 100-120-220-230V~
20 = fuse 6.3 x 32mm + voltage selector 100-120-230-240V~
21 = fuse 5 x 20mm + voltage selector 100-120-230-240V~
Approvals
29
Come and see ST’s solution showcase at CommunicAsia 2017!
Visitors to the ST booth can see a wide range of advanced driver assistance system (ADAS) components on the car smart cockpit model. Aiming to promote major progress in autonomous driving technology, ...
soso ST Sensors & Low Power Wireless Technology Forum
Official notice that SensorTag has been postponed to April 30, 2014!
I have communicated with most of the participants privately, and everyone generally reflected that the time was tight and the task was heavy, so we now officially notify you that the SensorTag competi...
phantom7 TI Technology Forum
Regarding the compilation error of the new project, please have a look at it
I created an MFC project based on the CHSEmu simulator in VS2005, but the error fatal error C1083: Cannot open include file: 'aygshell.h': No such file or directory appeared during compilation. The MF...
davidli88 Embedded System
Improving the design accuracy of GSM (EDGE) products
Although the third generation (3G) wireless communication technology has begun to emerge, wireless system designers have not slowed down their efforts to improve the data processing capabilities of ex...
tmily RF/Wirelessly
ARM Classic 300 Questions.pdf
Those who study ARM must read it, it is very useful....
mxdaiyi ARM Technology
EEWORLD University - TI 15.4 protocol stack and low-power long-distance sensor to cloud solution introduction
TI 15.4 protocol stack and low-power long-distance sensor to cloud solution introduction : https://training.eeworld.com.cn/course/4557TI 15.4-Stack is an RF communication stack based on IEEE 802.15.4e...
hi5 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1706  977  889  2047  2453  35  20  18  42  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号