F.MF.06A.06.16.FC

Description
Mains Power Connector, 6A, 250VAC, Male, Solder Terminal
CategoryThe connector    The connector   
File Size718KB,3 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

F.MF.06A.06.16.FC Overview

Mains Power Connector, 6A, 250VAC, Male, Solder Terminal

F.MF.06A.06.16.FC Parametric

Parameter NameAttribute value
MakerKEMET
Reach Compliance Codecompli
Other featuresSTANDARDS: IEC 60320, CSA, UL, VDE
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings6A, 250VAC
Manufacturer's serial numberF.MF
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
IEC Inlet Filters
With fuse holders and voltage selectors
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus input voltage selector
with 4 possible combinations. These features ensure the range is
ideally suited for manufacturers of business, consumer and medical
equipment for international markets.
F.MF-F.MG
series
Current ratings from 1A to 6A
Integral single or twin fuse holder
Voltage selector
Snap-in or screw mount versions
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320, 1 (F.MF) or 2 (F.MG) fuse
holders for fuses 5 x 20mm (IEC) or 6.3 x 32mm
(US), voltage selector with 4 possible combinations;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 2.8 x 0.5mm for voltage selector terminals;
ground terminal connected to case.
F.MF.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 2500
F.MG. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MF.01A.01.01.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Voltage selector:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
110-220-240Vac
100-120-220-240Vac
115-115-230-230Vac
110-220Vac
Leakage current (I
L
):
at 220V, 50Hz, max value
F = 1 fuse
G = 2 fuses
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
01 = fuse 5 x 20mm + voltage selector 110-220-240V~
02 = fuse 5 x 20mm + voltage selector 100-120-220-240V~
03 = fuse 5 x 20mm + voltage selector 115-115-230-230V~
08 = fuse 6.3 x 32mm + voltage selector 110-220-240V~
09 = fuse 6.3 x 32mm + voltage selector 100-120-220-240V~
10 = fuse 6.3 x 32mm + voltage selector 115-115-230-230V~
15 = fuse 5 x 20mm + voltage selector 110-220V~
16 = fuse 6.3 x 32mm + voltage selector 110-220V~
19 = fuse 5 x 20mm + voltage selector 100-120-220-230V~
20 = fuse 6.3 x 32mm + voltage selector 100-120-230-240V~
21 = fuse 5 x 20mm + voltage selector 100-120-230-240V~
Approvals
29
Network speed under WINCE system
Dear heroes: Assuming the development platform is PXA270+WINCE5.0, what is the actual transmission speed of a 100M network on a similar embedded platform? How to test it? Are there any test tools? Jus...
AVR_AFA Embedded System
Kudos to the moderator open82977352!
The National Undergraduate Electronic Design Competition has passed, and the competition section has naturally become "a lot more deserted", but the moderator open82977352 is still sticking to his pos...
小娜 Talking
A Difficulty in EDA Course Design
My class assignment is an electric sliding door, in which 59 pulses are needed to open the door, the first three pulses are spaced at 100ms, 60ms, and 30ms, then 51 pulses are spaced at 20ms, and the ...
谷溪玄牝 FPGA/CPLD
Lock the power management of win98
As we all know, Win95 has the function of setting passwords, but I wonder if you have noticed that when returning to Win95 from the "suspend" state, the system does not require us to enter a password....
birdpaladin Power technology
TFFS file system COPY symbol is undefined.
1. After creating TFFS, formatting FLASH and mounting it, I can see "/tffs" using the devs command in SHELL. I can execute LS and CD commands, but when I execute the copy command, it says that the sym...
you168you Embedded System
Altera-SoCFPGA-HelloWorld-Linux-GNU
Altera-SoCFPGA-HelloWorld-Linux-GNU...
雷北城 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1690  1508  2260  2747  1928  35  31  46  56  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号