Description
Electric Fuse, Time Delay Blow, 45A, 600VAC, 600VDC, 200000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size378KB,2 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

IDSR045 Overview

Electric Fuse, Time Delay Blow, 45A, 600VAC, 600VDC, 200000A (IR), Inline/holder,

IDSR045 Parametric

Parameter NameAttribute value
MakerLittelfuse
Reach Compliance Codeunknow
ECCN codeEAR99
Other featuresRATED BREAKING CAPACITY AT 600 VDC: 20000 A
Fusing characteristicsTIME DELAY
body height139.7 mm
Body length or diameter25.4 mm
Built-in featuresINDICATOR
Circuit protection typeELECTRIC FUSE
Installation featuresINLINE/HOLDER
physical size25.4mm x 139.7mm
Rated breaking capacity200000 A
Rated current45 A
Rated voltage (AC)600 V
Rated voltage (DC)600 V
GuidelineCE; CSA; UL
surface mountNO
Terminal shapeEND CAP
POWR-GARD
®
Fuse Datasheet
Class RK5 – IDsR seRIes InDICatoR
®
fuses
600 V AC/DC • Dual Element • Time-Delay •
1
/
10
-600 A
Ordering Information
/
/
15
/
100
2
/
10
1
/
4
3
/
10
4
/
10
1
/
2
1 10
1 8
/
/
1
1
1
/
8
1
1
/
4
1
4
/
10
1
1
/
2
1
6
/
10
6 10
8 10
1 /
2
2
1
/
4
2
1
/
2
2
8
/
10
3
3
2
/
10
3
1
/
2
8 10
ampeRe RatIngs
4
8
4
1
/
2
9
5
10
5
6
/
10
12
6
15
6
1
/
4
17
1
/
2
7
20
7
1
/
2
25
30
35
40
45
50
60
70
75
80
90
100
110
125
150
175
200
225
250
300
350
400
450
500
600
Note: All fuses rated 1A and above are Indicator
®
fuses.
seRIes
IDSR
amp
30
Catalog numbeR oRDeRIng numbeR
IDSR030
IDSR030.T
Web Resources
Description
The IDSR combines a 600 Vdc capability with indication to
provide an ideal solution for many DC applications.
Download TC Curves, CAD drawings and other technical
information:
littelfuse.com/idsr
Recommended Fuse Holders
LFR60 Series
Applications
• DC circuits
• Solar inverters
• Motors
• Transformers
• Solenoids
• Fluorescent lighting
Dimensions
Please refer to the Class R dimensions
Peak Let-Thru Curve
IDSR
1000000
Features/Benefits
• POWR-PRO
®
Performance
• Indication
PEAK LET-THRU IN AMPERES
100000
600 A
400 A
200 A
100 A
60 A
10000
30 A
15 A
Specifications
Voltage Ratings
Interrupting Ratings
AC: 600 V
DC: 600 V
AC: 200 kA rms symmetrical
300 kA rms symmetrical
(Littelfuse self-certified)
DC: 20 kA
1
/
10
– 600 A
Standard 248-12 and UL 198M, Class RK5
UL Listed (File: E81895)
CSA Certified (File: LR29862)
Ampere Range
Approvals
1000
100
10000
100000
2000000
Note: For more information, see Peak Let-Thru Table
100
AVAILABLE FAULT CURRENT
SYMMETRICAL R.M.S. AMPERES
1000
littelfuse.com
1 of 2
© 2014 Littelfuse POWR-GARD
®
Products
Rev: 020614
Does anyone know the standards for embedded OS? What does it mean that RTthread has passed GJB7718-2012 and GJB7706-2012?
I just saw the news that RTthread passed GJB7718-2012 and GJB7706-2012. What are the advantages of these two military standards and other industry standards, such as medical certification IEC-62304 Cl...
freebsder Embedded System
Looking to buy DM642 development board, second-hand is also acceptable~~
I need a DM642 board for my project. I mainly study the video-related algorithms on the DM642 platform. One video input, one composite video signal output, one network port output. The functional requ...
cooljuicy DSP and ARM Processors
【Xin Xin DIY】Cordless soldering iron V1.0
[size=7][color=#2e8b57][b]Pictures speak louder than words[/b][/color][/size]{:1_138:}...
辛昕 DIY/Open Source Hardware
stm32 remote upgrade
[size=5][color=#000][b]The design idea is as follows: immediately judge the value of the battery backup area register when power is turned on. If it is equal, clear the register value and then upgrade...
结束是开始 ARM Technology
PC and PDA serial communication problem
The problem is in the code comments. Could anyone help me? Thanks. ACCESSFILE_DATA is a structure I defined myself, as follows: typedef struct _ACCESSFILE_DATA { BOOL bResult; DWORD dwLastError; DWORD...
逍遥vs无聊 Embedded System
Why are there more male engineers than female engineers?
We all know that the male colleagues around us are much better than the female ones. In addition to innate factors, there must be something else!After spending so much time on the forum, I found that ...
jixfjixf Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 165  2694  1609  143  1753  4  55  33  3  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号