EEWORLDEEWORLDEEWORLD

Part Number

Search

55.14.8.240.2000

Description
Electromechanical Relay, 4PDT-CO, MBB, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.14.8.240.2000 Overview

Electromechanical Relay, 4PDT-CO, MBB, AC/DC Output

55.14.8.240.2000 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompli
ECCN codeEAR99
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)192 V
Coil resistance19100 Ω
Maximum coil voltage (AC)264 V
Nominal coil voltage240 V
Coil/Input Power TypeAC
Contact (AC) maximum rated power R load1750VA@250VAC
Contact (AC) maximum rated R load15A@250VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)250 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life150000 Cycle(s)
End contact materialSILVER CADMIUM OXIDE
Number of terminals14
operating hours11 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count14
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style4 FORM C
Relay function4PDT-CO
release time3 ms
Terminal length0.0048 inch
Termination typeSOLDER
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
Has anyone written a C language program to control the 12-bit AD TLV5616 using PIC16F877A?
I have searched for it on the Internet for a long time but couldn't find it. I really need help from the experts....
j513378451 Microchip MCU
repair
It just didn't spread...
cqwjfa MCU
Share a reference book on servo motor drive
Design of small AC servo motor control circuit...
xujihu Motor Drive Control(Motor Control)
The standby animation window cannot cover the soft keyboard window
Create a standby animation window: m_hwnd = CreateWindow(HHRESPGIFANIMATION_CLASSNAME, TEXT(""), WS_VISIBLE, 0, 0, 240, 320, 0, NULL, hInstance, NULL); SetWindowPos(m_hwnd, HWND_TOPMOST, 0, 0, 0, 0, S...
yjj1987 Embedded System
Wuhan and Shenzhen, tangled...
Dear people who have experienced this, please help! I have been working in Wuhan for two years since I graduated. The scale of the company is not bad (about 200 people). It makes charging piles. I fee...
石玉 Energy Infrastructure?
Is it necessary to open another cache for RS232 communication?
When sending data from the microcontroller memory to a PC, do we need to create a cache before sending it to SBUF, or can we directly transfer the data to SBUF?...
songguoda Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2712  2264  2794  2050  132  55  46  57  42  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号