EEWORLDEEWORLDEEWORLD

Part Number

Search

2635LHA211400L0

Description
Rocker Switch, (on)-on, Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2635LHA211400L0 Overview

Rocker Switch, (on)-on, Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2635LHA211400L0 Parametric

Parameter NameAttribute value
MakerAPEM
Reach Compliance Codecompli
ECCN codeEAR99
Actuator colorBLUE
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact function(ON)-ON
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch actionMOMENTARY
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
[LPC54100] My wife is going to give birth, so I need to take two weeks off!
My wife is about to give birth, the due date is March 20th, so I’m taking two weeks off!...
wo4fisher NXP MCU
Mobile/WinCE Sage
Nasdaq listed US company, located in Shanghai Zhangjiang Hi-tech Park, mainly engaged in communication chip design, 2.5G, 2.75G, 3G mobile phone chips occupy a considerable proportion of the market sh...
moto_jfx Embedded System
The output voltage of the switching power supply is too low
I just bought a switching power supply with two pairs of independent +12V and -12V outputs, but when it is unloaded, the +12V is generally low. I want to make a DC to DC solution to stabilize the outp...
fangfang120 Analog electronics
nRF905 sending address problem
I am a bit confused. There is an RF-Configuration-Register in nRF905, which contains a 32-bit RX address. Is this address the address of another nRF905 or the address of my current nRF905? If it is th...
爱好汽车电子 Microchip MCU
How to write the coordinator and terminal programs in the same file in ZigBee
The application layer function is to write the coordinator and the terminal node functions together. You can choose which node's function it is by selecting the workbench. But why does it feel like th...
永远不变的距离 RF/Wirelessly
Huawei FPGA Design Specifications
...
至芯科技FPGA大牛 FPGA/CPLD

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 973  330  2562  1078  152  20  7  52  22  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号