EEWORLDEEWORLDEEWORLD

Part Number

Search

2636LHC230400LI

Description
Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2636LHC230400LI Overview

Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2636LHC230400LI Parametric

Parameter NameAttribute value
MakerAPEM
Reach Compliance Codecompli
ECCN codeEAR99
Actuator colorBROWN
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialCOPPER
Center contact platingSILVER
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-ON
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialCOPPER
End contact platingSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
How to call webbrowser activex control under mfc
I right-clicked in the resource view and inserted the activex control, but the space registered on the pc was inserted and it cannot be used on the ppc. How can I correctly insert the webbrowser contr...
redfox29 Embedded System
Watch the video to win a JD card | Taixiang test of Shuige cheats
The gift that Brother Shui gave to the engineers was the "Winter Olympics Series" of Taixiang Testing. I believe that the wonderful scenes of the Winter Olympics and the lovely image of Bing Dwen Dwen...
EEWORLD社区 Test/Measurement
Saber simulation results are a bit strange, let's see what's going on
I used Saber to simulate a triangle wave generating circuit. This circuit has been verified on the PCB to generate PWM waves, but the Saber simulation is a DC signal. See the figure above. Why is this...
nevermore151237 Power technology
NXP Selection Guide
NXP Semiconductors NV (Nasdaq: NXPI) offers high performance mixed signal ([/size][/font][/backcolor][/font][backcolor=rgb(238, 238, 238)][font=Verdana, Helvetica, Arial, sans-serif][size=12px]with it...
seamusjohn NXP MCU
A Gathering of the Best Set-Top Box Chip Solutions
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:01[/i][indent]The AVS standard was officially approved as a national standard in March 2006. Due to its high coding efficiency and low ...
26979746 Mobile and portable
The motor coil is an inductive load, so the current in the coil will have a certain delay relative to the load voltage on the coil.
Lead Angle is often used in brushless DC motor (BLDC - BrushLess DC) control. Because the motor coil is an inductive load, the current in the coil will have a certain delay relative to the load voltag...
李二峰 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2449  1118  394  98  2416  50  23  8  2  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号