HVCG2512JBL22K0

Description
Fixed Resistor, Metal Glaze/thick Film, 2W, 22000ohm, 3000V, 5% +/-Tol, 200ppm/Cel, Surface Mount, 2512, CHIP
CategoryPassive components    The resistor   
File Size133KB,3 Pages
ManufacturerSEI(Stackpole Electronics Inc.)
Websitehttps://www.seielect.com/
Environmental Compliance  
Download Datasheet Parametric View All

HVCG2512JBL22K0 Overview

Fixed Resistor, Metal Glaze/thick Film, 2W, 22000ohm, 3000V, 5% +/-Tol, 200ppm/Cel, Surface Mount, 2512, CHIP

HVCG2512JBL22K0 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSEI(Stackpole Electronics Inc.)
package instructionSMT, 2512
Reach Compliance Codecompli
ECCN codeEAR99
structureRectangul
JESD-609 codee4
Installation featuresSURFACE MOUNT
Number of terminals2
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Package height0.76 mm
Package length6.35 mm
Package formSMT
Package width3.18 mm
method of packingBulk
Rated power dissipation(P)2 W
Rated temperature70 °C
resistance22000 Ω
Resistor typeFIXED RESISTOR
size code2512
surface mountYES
technologyMETAL GLAZE/THICK FILM
Temperature Coefficient200 ppm/°C
Terminal surfaceGold (Au)
Terminal shapeWRAPAROUND
Tolerance5%
Operating Voltage3000 V
HVC Series
High Voltage Thick Film Chip Resistor
Features:
Absolute voltage ratings up to 25,000 volts
Ohmic values to 50G
Available with wire bondable terminations
Tight tolerances to 0.1%
Utilizes fine film resistor deposition technology
Superior pulse handling capabilities
Low TCR to 25 ppm/ºC
Low VCR to 1 ppm/volt
Very low noise
Ultra high stability
Custom sizes available
Standard HVC parts are unmarked
RoHS compliant / lead-free
Stackpole Electronics, Inc.
Resistive Product Solutions
Electrical Specifications
Type
Package
Type
Power
Rating (3)
(Watts) @
70ºC
0.06W
Maximum
Working
Voltage (1)
Absolute
Maximum
Voltage (2)
Resistane
Temperature
Coefficient
± 50 ppm/ºC
HVC0603
0603
400V
5KV
± 100 ppm/ºC
± 200 ppm/ºC
± 50 ppm/ºC
HVC0805
0805
0.2W
600V
10KV
± 100 ppm/ºC
± 200 ppm/ºC
± 25 ppm/ºC
HVC1206
1206
0.33
1200V
15KV
± 50 ppm/ºC
± 100 ppm/ºC
± 200 ppm/ºC
± 25 ppm/ºC
HVC2010
2010
1W
1,700V
20KV
± 50 ppm/ºC
± 100 ppm/ºC
± 200 ppm/ºC
± 25 ppm/ºC
HVC2512
2512
2W
2,500V
25KV
± 50 ppm/ºC
± 100 ppm/ºC
± 200 ppm/ºC
± 25 ppm/ºC
HVC3512
3512
3W
3,500V
40KV
± 50 ppm/ºC
± 100 ppm/ºC
± 200 ppm/ºC
1M - 10M
100K - 10M
10K - 10M
10K - 10M
1M - 10M
100K - 10M
10K - 10M
10K - 10M
1M - 100M
10K - 100M
10K - 100M
1M - 100M
10K - 100M
10K - 100M
1M - 100M
10K - 100M
10K - 100M
1M - 100M
10K - 100M
10K - 100M
1M - 500M
10K - 500M
10K - 500M
1M - 500M
10K - 500M
10K - 500M
Ohmic Range (Ω) and Tolerance
0.1%
0.25%
0.5%
10K - 10M
10K - 10M
10K - 10M
10K - 10M
10K - 10M
10K - 10M
1M - 100M
10K - 500M
10K - 500M
1M - 100M
10K - 500M
10K - 500M
1M - 500M
100K - 1G
10K - 1G
10K - 1G
1M - 500M
100K - 1G
10K - 1G
10K - 1G
1%
10K - 100M
10K - 500M
10K - 500M
10K - 500M
10K - 1G
10K - 1G
1M - 100M
10K - 1G
10K - 1G
1M - 100M
10K - 1G
10K - 1G
1M - 500M
100K - 1G
10K - 10G
10K - 10G
1M - 500M
100K - 1G
10K - 10G
10K - 10G
2%
10K - 500M
10K - 1G
10K - 1G
10K - 500M
10K - 1G
10K - 1G
1M - 100M
10K - 1G
10K - 10G
1M - 100M
10K - 1G
10K - 10G
1M - 500M
100K - 1G
10K - 10G
10K - 10G
1M - 500M
100K - 1G
10K - 10G
10K - 10G
5%
10K - 500M
10K - 1G
10K - 1G
10K - 500M
10K - 1G
10K - 10G
1M - 100M
10K - 1G
10K - 10G
1M - 100M
10K - 1G
10K - 10G
1M - 500M
100K - 1G
10K - 10G
10K - 10G
1M - 500M
100K - 1G
10K - 10G
10K - 10G
10%
10K - 500M
10K - 10G
10K - 10G
10K - 500M
10K - 1G
10K - 10G
1M - 100M
10K - 1G
10K - 10G
1M - 100M
10K - 1G
10K - 10G
1M - 500M
100K - 1G
100K - 50G
100K - 50G
1M - 500M
100K - 1G
100K - 50G
100K - 50G
20%
10K - 500M
10K - 10G
10K - 50G
10K - 500M
10K - 1G
10K - 50G
1M - 100M
10K - 1G
10K - 10G
1M - 100M
10K - 1G
10K - 10G
1M - 500M
100K - 1G
100K - 50G
100K - 50G
1M - 500M
100K - 1G
100K - 50G
100K - 50G
100K - 100M 100K - 500M 100K - 500M 100K - 500M 100K - 500M 100K - 500M 100K - 500M
100K - 100M 100K - 500M 100K - 500M 100K - 500M 100K - 500M 100K - 500M 100K - 500M
100K - 100M 100K - 500M
100K - 100M 100K - 500M
(1) The continuous maximum voltage applied cannot exceed the maximum power rating and is ohmic value dependent.
(2) To achieve, the terminals must be properly isolated from each other with appropriate potting material.
(3) Contact factory for higher power ratings: 0805: 0.2W 1206:0.33W 2010: 1W 2512: 2W
Note: Other case sizes and tolerances are available.
Rev Date: 11/02/2011
This specification may be changed at any time without prior notice
Please confirm technical specifications before you order and/or use.
1
www.seielect.com
marketing@seielect.com
CS5523 Issues
I just graduated and want to design an industrial remote control with a joystick. Does anyone have the relevant application circuit of CS5523? Please send it to me. Thank youQQ674118202...
xibeifengse Microcontroller MCU
Three strategies to make good career planning and get rid of the "chaotic" state
In a highly competitive workplace, workplace "idlers" have similar common problems: no sense of value in work, confused future and no way out; serious career crisis, marginalized, and become the "invi...
ESD技术咨询 Talking about work
Phase loss detection of three-phase three-wire circuit
[i=s] This post was last edited by New Electrician Seeking Guidance on 2020-4-1 14:10[/i]I am going to make a soft start switch for a three-phase circuit recently, which needs to realize the phase los...
电工新手求指导 Analog electronics
Buy RIGOL oscilloscope at a special price and get a JD shopping card
[font=微软雅黑][size=3] To meet the basic testing requirements of electronics enthusiasts and engineers, and to allow everyone to enjoy more favorable prices and convenient purchasing methods, RIGOL has l...
eric_wang Mobile and portable
Share your experience on DSP optimization
[size=3]C6XX optimization experience summary[/size] [size=3]I. Common options for c6x compilation[/size] [size=3](I) The compiler of c6x is “cl6x.exe" usage[/size] [size=3] [/size] [size=3]Cl6x [optio...
Jacktang DSP and ARM Processors
Use of UPS power supply in operator station
The power supply system of a thermal power plant is not continuous and constant. The start and stop of large equipment, the switch operation, the long-term heavy load on the electrical working section...
vini Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 66  828  2762  2787  1384  2  17  56  57  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号