• Transformer Coupled Across 70 ohms, Measured on Stub:
• BU-63147/157XX-XX0
• BU-63147X3-XX2 (Note 9)
Output Noise, Differential (Direct Coupled)
Output Offset Voltage, Transformer Coupled Across 70 ohms
Rise/Fall Time
• BU-63147/157X3
• BU-63147X4
LOGIC
V
IH
V
IL
I
IH
Tx
Data In
, Tx
Inhibit
, Rx
Strobe
I
IL
Tx
Data In
, Tx
Inhibit
, Rx
Strobe
V
OH
(Vcc=4.75V,I
OH
=max)
V
OL
(Vcc=4.75V,I
OH
=max)
I
OL
I
OH
6
18
20
-250
100
200
7
20
22
150
150
250
9
27
27
10
250
300
300
Vp-p
Vp-p
Vp-p
mVp-p, diff
mVp-p, diff
ns
ns
2.0
20
-100
2.4
0.4
3.4
-3.4
0.8
100
-20
V
V
µA
µA
V
V
mA
mA
POWER SUPPLY REQUIREMENTS
Voltages/Tolerances
• +5V
Current Drain (Total Hybrid)
BU-63147/157/XX-XX0
• Idle (Both Channels)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
BU-63147/X3-XX2
• Idle (Both Channels)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
4.75
5.0
80
199
286
455
80
210
308
500
5.25
100
229
348
535
100
240
370
580
V
mA
mA
mA
mA
mA
mA
mA
mA
Data Device Corporation
www.ddc-web.com
3
BU-63147
P-07/12-0
TABLE 1. BU-63147/157 SPECIFICATIONS (CONT.)
PARAMETER
POWER DISSIPATION (NOTE 10)
Total Hybrid
BU-63147/157/XX-XX0
• Idle (Both Channels)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
BU-63147/X3-XX2
• Idle (Both Channels)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
Hottest Die
BU-63147/157/XX-XX0
• Idle (One Channel)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
BU-63147/X3-XX2
• Idle (One Channel)
• 25% Transmitter Duty Cycle (One Channel)
• 50% Transmitter Duty Cycle (One Channel)
• 100% Transmitter Duty Cycle (One Channel)
THERMAL
• Thermal Resistance, Junction-to-Case, Hottest Die (θ
JC
)
• Operating Junction Temperature
• Storage Temperature
• Lead Temperature (soldering, 10 sec.)
PHYSICAL CHARACTERISTICS
Size
36-Pin DIP
36-Lead Flat pack
Weight
MIN
TYP
MAX
UNITS
0.4
0.65
0.73
0.88
0.4
0.7
0.84
1.1
0.2
0.43
0.59
0.78
0.2
0.48
0.7
1.00
0.5
0.8
1.04
1.28
0.5
0.85
1.15
1.50
0.25
0.6
0.84
1.13
0.25
0.65
0.95
1.35
12
150
150
+300
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
°C/W
°C
°C
°C
-55
-65
1.900 x .800 x .205
(48.26 x 20.32 x 5.21)
1.900 x .800 x .200
(48.26 x 20.32 x 5.08)
0.6
(17)
in.
(mm)
in.
(mm)
oz
(g)
Notes:
Notes 1 through 6 are applicable to the Receiver Differential Resistance and Differential Capacitance specifications:
(1) Specifications include both transmitter and receiver (assumed tied together externally).
(2) Impedance parameters are specified directly between pins TX/RX A(B) and TX/RX A(B) hybrid.
(3) It is assumed that all power and ground inputs to the hybrid are connected and that the hybrid case is connected to ground for the impedance measurement.
(4) The specifications are applicable for both unpowered and powered conditions.
(5) The specifications assume a 2 volt rms balanced, differential, sinusoidal input. The applicable frequency range is 75 kHz to 1 MHz.
(6) Minimum resistance and maximum capacitance parameters are guaranteed over the operating range, but are not tested.
(7) The Threshold Level, as referred to in this specification, is meant to be the maximum peak-to-peak voltage (measured on the data bus) that can be applied to the
receiver's input without causing the output to change from the OFF state.
(8) Assumes a common mode voltage within the frequency range of dc to 2 MHz, applied to pins of the isolation transformer on the stub side (either direct or transformer
coupled), and referenced to transceiver ground. Transformer must be a DDC recommended transformer or other transformer that provides an equivalent minimum
CMRR.
(9) MIL-STD-1760 requires minimum output voltage of 20 Vp-p on the stub connection. The -XX2 option is
not
available for the BU-63147X4 or BU-63157 versions.
(10) Power dissipation specifications assume a transformer coupled configuration, with external dissipation (while transmitting) of 0.14 watts for the active isolation trans-
former, 0.08 watts for the active coupling transformer, 0.45 watts for each of the two bus isolation resistors, and 0.15 watts for each of the two bus termination resistors.
(11) Assuming the use of isolation transformers with the turns ratios shown in Figure 3 and in the absence of common mode signal on the 1553 stub, this equates to a
nominal stub voltage of 38 Volts
PK-to-PK
transformer-coupled, or 53 Volts
PK-to-PK
direct-coupled.
Data Device Corporation
www.ddc-web.com
4
BU-63147
P-07/12-0
TABLE 2. BU-63157 RADIATION SPECIFICATIONS*
PART NUMBER
BU-63157X3
TOTAL DOSE
100 KRAD
SINGLE EVENT
LATCHUP
IMMUNE
INTRODUCTION
The BU-63147/157 is a dual redundant transmitter and receiver
packaged in a 36-pin DDIP or flat pack. It is directly compatible to
Harris 15530 encoder/decoder and has internal (factory preset)
threshold levels. The dual transceiver only requires +5V power
and conforms to MIL-STD-1553A and 1553B. For McAir compat-
ibility, versions are available with rise/fall times of 200 to 300
nsec.
Figure 3 illustrates the connection between a BU-63147/157
transceiver and a MIL-STD-1553 Data Bus. After transformer
isolating the transceiver, it can be either direct coupled (short
stub) or transformer coupled (long stub) to the Data Bus.
*Note: Radiation parameters specified on this data sheet are derived from initial
qualification testing by DDC and published data from ASIC manufacturers. These
devices have not been evaluated for compliance to the RHA requirements stipu-
lated in MIL-PRF-38534, Appendix G.
TABLE 3. HIGH RELIABILITY SCREENING OPTIONS
FOR BU-63157
ELEMENT EVALUATION
Visual Inspection:
Integrated Circuits
Transistor & Diodes
Passive Components
METHOD
TRANSMIT OPERATING MODE
MIL-STD-883, Method 2010 Condition A
MIL-STD-750, Method 2072 and 2073
MIL-STD-883, Method 2032 Class S
SEM Analysis for Integrated MIL-STD-883, Method 2018
Circuits
Element Evaluation:
Visual, Electrical, Wire
Bondability, 24-Hour
Stabilization Bake, 10
Temperature Cycles,
5000 g’s constant accelera-
tion, 240-Hour Powered
Burn-In and 1000-Hour Life
Test (Burn-In and 1000-
Hour Life Test are Only
Required for Active
Components.)
ASSEMBLY & TEST
Particle Impact Noise
Detection (PIND)
320-Hour Burn-In
(Standard on this device)
100% Non-Destructive
Wirebond Pull
(Standard on this device)
Radiographic (X-Ray)
Analysis
QCI TESTING
Extended Temperature
Cycling:
20 Cycles Including
Radiographic (X-Ray)
Testing
Moisture Content Limit of
5000 PPM
MIL-STD-883, Method 2020
Condition A
MIL-STD-883, Method 1015
The transmitter section accepts encoded TTL data and converts
it to phase-modulated bipolar form using a waveshaping network
and driver circuits. The driver outputs TX DATA OUT and TX DATA
OUT are transformer coupled to the Data Bus.
The transmitter output terminals can be put into a high imped-
ance state by setting INHIBIT high, or setting TX DATA IN and TX
DATA IN to the same logic level. The operating modes are shown
in TABLE 4.
The transceivers are able to operate in a “wraparound” mode.
This allows output data to be monitored by the receiver section
and returned to the decoder where it is checked for errors.
MIL-PRF-38534
TABLE 4. TRANSMIT OPERATING MODE
TX DATA IN
X
0
0
MIL-STD-883, Method 2023
1
1
MIL-STD-883, Method 2012
TX DATA IN
X
0
1
0
1
TX INHIBIT
H
X
L
L
X
DRIVER OUTPUT
OFF (NOTE)
OFF
TX DATA OUT ON,
TX DATA OUT OFF
TX DATA OUT ON,
TX DATA OUT OFF
OFF
NOTE: DRIVER OUTPUT terminals are in the high impedance mode during
[i=s]This post was last edited by johnrey on 2016-6-28 12:24[/i] This is the request that comrade nmg put forward in the first post, asking whether these two guys can be used together. At that time, I...
The error message is: gmake: *** No rule to make target `../F28335.cmd', needed by `ADCSAOPINFLASH.out'. There is no problem with the cmd file. Is there a problem with the program?...
[align=left]Estimating the temperature rise of a semiconductor is simple. You simply calculate the power dissipation of the component and then use an electrical simulation of the cooling circuit to de...
When using Designer to simulate the IBIS model of DAC5672, when simulating the output port of the DAC, should a sinusoidal signal be added to the input port, and the output should be an analog signal,...
WINCE6.0 system, the development board is PXA310, the WIFI driver is also built-in, and the compilation is successful. The generated NK.nb0 is burned to the development board. Now the WIFI module is p...
"The boss of a local IC design company was called a 'liar' by people in the industry because the performance of its products did not match the publicity!" "The products of a local power IC design comp...
On August 24th, Tesla CEO Elon
Musk
revealed information about the upcoming FSD V14, claiming it will outperform human drivers. Tesla FSD lead Ashok stated last year that FSD version 12.5, ...[Details]
A parallel inverter consists of two thyristors (T1 and T2), a capacitor, a center-tapped transformer, and an inductor. The thyristors provide a current path, while the inductor L maintains a consta...[Details]
To understand why car engines need gearboxes, we must first understand the characteristics of different types of engines. An engine refers to a machine that can convert a form of energy into kineti...[Details]
In recent years, many people have switched to new energy vehicles, and this type of vehicle has indeed been highly sought after and is considered the future direction of automobile development, and...[Details]
Current Development Status of DVR Market
A DVR, or digital video recorder, uses a hard disk for recording, unlike traditional analog video recorders. It's often called a DVR because it's a com...[Details]
On August 18th, Galaxis, a specialist in integrated intelligent intralogistics robotics, officially unveiled its next-generation, ultra-narrow aisle forklift mobile robot, the "VFR Ultra-Narrow Ser...[Details]
1. Ease of Use: The HMI module should be designed to be simple and clear, allowing users to easily operate and configure the energy storage device.
2. Ease of Maintenance: The HMI module should...[Details]
A half-bridge is an inverter topology for converting DC to AC. A typical half-bridge circuit consists of two controller switches, a three-wire DC power supply, two feedback diodes, and two capacito...[Details]
1. Multi-channel DAC technology bottleneck
Currently,
the development of multi-channel DAC technology focuses on two core challenges.
First, industrial applications urgently ...[Details]
On August 22, according to CNBC's report today, the National Highway Traffic Safety Administration (NHTSA) is launching an investigation into Tesla, and the latter is questioned whether it has fail...[Details]
There are many motors that can use thyristor speed control, and they can be used in almost all industries. Various types of motors, such as fans, pumps, AC motors, DC motors, torque motors, single-...[Details]
I recently read an article in the Wall Street Journal titled "We need the right to repair our gadgets" (reference original article: ). The author was very angry about the phenomenon of "planned obs...[Details]
introduction
The widespread use of air conditioner communication circuits began with the rise of household inverter air conditioners. With China's energy conservation and emission reduction in...[Details]
0 Introduction
With a rapidly aging population, a young couple is now required to care for an increasing number of elderly people, leading to a growing difficulty in providing care for them. E...[Details]
Silicon Labs (also known as "Silicon Labs"), an innovative leader in low-power wireless connectivity, will showcase its cutting-edge artificial intelligence (AI) and Internet of Things (IoT) solu...[Details]