Description
Modular Terminal Block, 4A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size88KB,1 Pages
ManufacturerWieland Electric GmbH
Websitehttps://www.wieland-electric.com/
Download Datasheet Parametric View All

78.011.2053.0 Overview

Modular Terminal Block, 4A, 1 Row(s), 1 Deck(s)

78.011.2053.0 Parametric

Parameter NameAttribute value
MakerWieland Electric GmbH
Reach Compliance Codecompli
ECCN codeEAR99
Other featuresPOLYCARBONATE, 94V-0
Manufacturer's serial number78
Number of layers1
Rows1
Number of channels20
Rated current4 A
Rated voltage100 V
safety certificateUL; CSA
Terminal and terminal strip typesMODULAR TERMINAL BLOCK
Base Number Matches1
revos
revos
FLEX
Modular industrial multipole connectors
Technical information
Modular inserts
Number of poles of the modular inserts
3pole
turned contact Ø
Connection range
current / UL/CSA
Rated voltage
Mains voltage / UL/CSA
Insulating material
Color
Flammability class
4pole + ground
punched ontact Ø
Connection range
current
Rated voltage
Insulating material
3.6 mm
see crimp contact Rated
max. 40 A / 35 A
630 V/8 kV/3
690 V AC / 600 V
PC, halogen-free
pepple gray, RAL 7032
UL 94 V-0
Part no.
Stand. pack
Approval/
Crimp contacts
mm
2
Contact Ø 3.6 mm
4.0
Male
contact
6.0
10.0
Female
4.0
contact
6.0
10.0
Contact material
Contact surface
Contact Ø 2.5 mm
Male
0.5 – 1.5
1.5 – 2.5
contact
0.5 – 1.5
Female
1.5 – 2.5
contact
AWG
12
10
8
12
10
8
Part no.
Stand. pack
100
100
100
100
100
100
qw
Modular male insert
Modular fem. insert
78.014.0353.0
78.004.0353.0
10
10
05.544.3129.8
05.544.3229.8
05.544.3329.8
02.125.3129.8
02.125.3229.8
02.125.3329.8
copper alloy
Ag
2.5 mm
see crimp contact Rated
max. 16 A
1000 V/8 kV/3
PA 6.6 GF,
halogen-free
Color
black
Flammability class UL 94 V-0
5pole
turned contact Ø
Connection range
current
Rated voltage
Insulating material
Color
Flammability class
q
20
16
20
16
16
14
16
14
05.544.3429.8
05.544.3529.8
02.125.3429.8
02.125.3529.8
100
100
100
100
Mod. male insert
Mod. fem. insert
78.013.0453.0
78.003.0453.0
10
10
Contact material
Contact surface
copper alloy
Ag
20
18
16
14
12
20
18
16
14
12
05.544.3629.8
05.544.3729.8
05.544.3829.8
05.544.3929.8
05.544.4029.8
02.125.3629.8
02.125.3729.8
02.125.3829.8
02.125.3929.8
02.125.4029.8
copper alloy
Ag
100
100
100
100
100
100
100
100
100
100
qw
2.5 mm
see crimp contact Rated
max. 20 A
250 V/6 kV/3
PC, halogen-free
pepple gray, RAL 7032
UL 94 V-0
Mod. male insert
Mod. fem. insert
78.013.0553.0
78.003.0553.0
10
10
Contact Ø 2.5 mm
Male
0.5
contact 0.75 – 1.0
1.5
2.5
4.0
Female
0.5
contact 0.75 – 1.0
1.5
2.5
4.0
Contact material
Contact surface
Contact Ø 1.6 mm
Male
0.14 – 0.37
contact
0.5
0.75 – 1.0
1.5
2.5
Female 0.14 – 0.37
contact
0.5
0.75 – 1.0
1.5
2.5
Contact material
Contact surface
Contact Ø 1.0 mm
0.09 – 0.25
Male
contact 0.25 – 0.5
Female 0.09 – 0.25
contact 0.25 – 0.5
10pole
turned contact Ø
Connection range
current
Rated voltage / UL/CSA
Insulating material
Color
Flammability class
1.6 mm
see crimp contact Rated
max. 10 A
250 V/4 kV/3/ 240 V
PC, halogen-free
pepple gray, RAL 7032
UL 94 V-0
qw
Mod. male insert
Mod. fem. insert
78.012.1053.0
78.002.1053.0
10
10
26 – 22 05.544.4129.8
05.544.4229.8
20
05.544.4329.8
18
05.544.4429.8
16
05.544.4529.8
14
26 – 22 02.125.4129.8
02.125.4229.8
20
02.125.4329.8
18
02.125.4429.8
16
02.125.4529.8
14
copper alloy
Ag
100
100
100
100
100
100
100
100
100
100
20pole
punched ontact Ø
Connection range
current / UL/CSA
Rated voltage / UL/CSA
Insulating material
Color
Flammability class
1.0 mm
see crimp contact Rated
max. 4 A / 5 A
100 V/1.5 kV/3 / 60 V
PC, halogen-free
pepple gray, RAL 7032
UL 94 V-0
qw
28 –
24 –
28 –
24 –
24
20
24
20
05.544.4629.7
05.544.4729.7
02.125.4629.7
02.125.4729.7
100
100
100
100
Male module Female 78.011.2053.0
module
78.001.2053.0
10
10
Contact material
Contact surface
copper alloy
Au
740
The program can be run in the Keil environment and communication is normal; but when leaving the Keil environment and powering on again, it cannot run normally?
[size=5]I can run the program in the Keil environment and the communication is normal; but when I leave the Keil environment and power on again, it fails to run normally? [/size]...
benbending Microcontroller MCU
Talk about the blink routine of the M3 side of F28M35
Let’s start with the simple ones.1. The program first performs HWREG(SYSCTL_MWRALLOW) = 0xA5A5A5A5; because // 0xA5A5A5A5 must be written before some registers protected by MWRALLOW can be rewrittenFo...
hlx3012 Microcontroller MCU
Help: IIR filter designed by myself
Yesterday I designed an IIR filter and wrote a test program: the filter is a low-pass filter, which is required to filter out the frequency band above 20KHZ. The program is as follows: #include "filte...
sakya DSP and ARM Processors
【TI Wireless Theme Collection】+BLE Chip Selection
Experience in selecting BLE chips Currently, the mainstream Ble single-mode chips include CSR's CSR1000 series, TI's cc254X, NORDIC's nrf800x and nrf51822, and Broadcom's bcm20732. Since the Bluetooth...
mars4zhu Wireless Connectivity
Patrol car creative progress post based on RL78 microcontroller + (with Renesas tutorial ~ very detailed) LED is only lit today
[size=6][b]Today, I just lit up the LED, which really made me feel like I was starting to learn 51 single-chip microcomputers... I referred to the G13 board provided by Renesas during the national com...
a972043362 Renesas Electronics MCUs
Help: Tornado 2.2 PowerPC C++ driver problem.
下面是编译信息: vxrm *.o *.rpo ctdt.c symTbl.c vxApp* *.out *.pl vxrm ..\prjComps.h ..\prjParams.h ..\prjConfig.c ..\linkSyms.c vxrm ..\libs.nm ..\libs.size F:\tornado2.2\host\gnu\3.3\x86-win32\bin\ccppc -g ...
100mdppp Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 245  279  1417  1587  1037  5  6  29  32  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号