Railway/Transportation system applications including communications systems, informa-
tion display, lighting, control systems, ticket machines, passenger
entertainment, public address systems, door control, industrial power systems and power
generation systems.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V110B24C200BL
V1 1 0 B
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
75W, 100W
5V
100W, 150W
8V
150W
12V
150W, 200W
15V
150W, 200W
24V
150W, 200W
28V
150W, 200W
36V
150W, 200W
48V
150W, 200W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
Vout only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
=
8V
12
=
12V
15
=
15V
24
=
24V
28
=
28V
36
=
36V
48
=
48V
110V Mini Family
Page 1 of 14
Rev 3.4
10/2016
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
54
155.5
64
56
161.7
169.4
1.3
Min
66
Typ
110
Max
154
250
65.4
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
Per EN50155 and GBT-25119
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
% V
OUT
nom.
%
% / °C
%
%
Notes
Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+Out to –Out, +Sense to –Out — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
For important information relative to applications where the converter modules are subject to continuous dynamic loading,
contact Vicor applications engineering at 800-927-9474.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Thermal capacity
Min
Typ
0.16
0.14
8.0
1.9
83
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
110V Mini Family
Page 2 of 14
Rev 3.4
10/2016
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (in to out)*
Isolation test voltage (in to base)*
Isolation test voltage (out to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
3.1
(89.3)
3.5
(99.6)
100
3000
1500
500
10
3.5
(100.3)
3.9
(110.6)
115
cURus, cTÜVus, CE
3.9
(111.3)
4.3
(121.6)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
in to out, in to baseplate, out to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
110V Mini Family
Page 3 of 14
Rev 3.4
10/2016
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3
V
OUT
, 100W (e.g. S110B3V3C100BL, V110B3V3C100BL)
Parameter
Efficiency
S110B3V3C100BL (enhanced efficiency)
V110B3V3C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.1
81.5
4.14
Typ
86.5
82.6
80
4.3
2.6
±0.02
34.8
34.8
Max
Unit
%
100
4.46
3.4
±0.2
30.3
41
41
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.9
21.2
3.3
V
OUT
, 75W (e.g. S110B3V3C75BL, V110B3V3C75BL)
Parameter
Efficiency
S110B3V3C75BL (enhanced efficiency)
V110B3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.2
81.0
4.14
Typ
86.0
81.9
80
4.3
2.6
±0.02
26.1
26.1
Max
Unit
%
100
4.46
3.6
±0.2
22.73
30.7
30.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
23.1
15.8
5
V
OUT
, 150W (e.g. S110B5C150BL, V110B5C150BL)
Parameter
Efficiency
S110B5C150BL (enhanced efficiency)
V110B5C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.4
83.9
6.03
Typ
88.5
84.8
85
6.25
5.3
±0.02
34.5
34.5
Max
Unit
%
107
6.47
7.5
±0.2
30
40.5
40.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.6
21
5
V
OUT
, 100W (e.g. S110B5C100BL, V110B5C100BL)
Parameter
Efficiency
S110B5C100BL (enhanced efficiency)
V110B5C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
80.5
6.03
Typ
86.0
81.9
240
6.25
3.4
±0.02
23
23
Max
Unit
%
300
6.47
4.4
±0.2
20
27
27
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
14
110V Mini Family
Page 4 of 14
Rev 3.4
10/2016
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
8
V
OUT
, 150W (e.g. S110B8C150BL, V110B8C150BL)
Parameter
Efficiency
S110B8C150BL (enhanced efficiency)
V110B8C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.3
85.5
9.36
Typ
89.0
86.8
200
9.7
5.2
±0.02
21.6
21.6
Max
Unit
%
250
10.1
6.4
±0.2
18.75
25.4
25.4
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
19.1
13.1
12
V
OUT
, 200W (e.g. S110B12C200BL, V110B12C200BL)
Parameter
Efficiency
S110B12C200BL (enhanced efficiency)
V110B12C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.9
86.0
13.7
Typ
89.0
87.2
185
14.3
7
±0.02
19.2
19.2
Max
Unit
%
232
14.9
8.2
±0.2
16.67
22.6
22.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
17
11.6
12
V
OUT
, 150W (e.g. S110B12C150BL, V110B12C150BL)
Parameter
Efficiency
S110B12C150BL (enhanced efficiency)
V110B12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.9
87.0
13.7
Typ
90.0
88.0
160
14.3
4.7
±0.02
14.4
14.4
Max
Unit
%
200
14.9
5.8
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
15
V
OUT
, 200W (e.g. V110B15C200BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.0
17.1
Typ
88.1
240
17.8
7.3
±0.02
15.3
15.3
Max
300
18.5
8.2
±0.2
13.33
18
18
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I won't elaborate on the reasons, but simply list some incomplete test data. For those who don't want to or feel it's unnecessary to buy a FLUKE meter, it may be of some reference value. The test mete...
//**************************************************************************** // Serial port 1 sends data function//************************************************************************ void Send_...
Je-Hyun Kim's degradable, grass-covered phone is made of hay and some degradable materials. It was presented as the "Natural Year Phone" in 2008. It is the first mobile phone with a shelf life. This g...
[flash]http://player.youku.com/player.php/sid/XMjY5NzA2NDA4/v.swf[/flash] [[i] This post was last edited by Texas Instruments DSP New World on 2011-5-24 17:44[/i]]...
S3C2410 uses the Ucos operating system. I want to use the GPRS module to send data to the host computer. However, the current problem is that after S3C2410 uses serial port 1 to send data to the modul...
As time goes by, people are increasingly concerned about their own and their families' health. However, existing monitoring devices for individual vital signs have struggled to gain market share du...[Details]
When we pick up an unfamiliar object, the first thing we want to know is what it actually does. A drive shaft, as the name suggests, is a shaft that transmits power. It's the transmission medium th...[Details]
Electronics engineers all know that transient voltage suppression (TVS) diodes are used to protect ports, preventing damage to downstream circuits caused by transient voltage surges. In short, TVS ...[Details]
With the global number of new energy vehicles expected to exceed 45 million by 2025, the performance boundaries of battery management systems are being reshaped.
Infineon Technologies
'
...[Details]
Relying on Zena CSS and Arm's complete partner ecosystem, we will accelerate the implementation of autonomous driving.
Close your eyes and imagine yourself getting into your car, rea...[Details]
Due to limitations in size, weight, and cost, most continuous-wave radar seekers use single-antenna technology. Insufficient isolation between the transmitter and receiver causes the transmitted si...[Details]
introduction
With the continuous development of electronic technology and the continuous upgrading of medical equipment, the demand for medical liquid infusion precision is becoming increasing...[Details]
According to reports from Xinhua News Agency, Tianjin University official website and other media, Chinese researchers have recently broken through the bottleneck of energy density and application ...[Details]
Coherent Corp., a Saxonian-based materials, networking, and laser technology company, has officially opened a new $127 million manufacturing facility in the Nhon Trach Industrial Park in Dong Nai P...[Details]
Today, we'll discuss why contactors shouldn't be connected to the output terminals of VFDs. This is because if the contactor at the VFD output isn't engaged, it will only engage when the VFD starts...[Details]
Momenta's self-developed assisted driving chip has been successfully launched and entered the actual vehicle testing phase. This is the first time that Momenta has "settled" its own algorithm on an...[Details]
The battery in an electric car is related to the vehicle's performance. As one of the core components of the vehicle, the battery cell has become an important reference for evaluating the quality o...[Details]
To address the pain points of traditional discrete solutions in the automotive intelligent actuator market, such as high complexity, high cost, and insufficient reliability, Naxin Micro has launche...[Details]
What is a smart home
? The term "smart home" has become widely used, with many security and building intercom manufacturers claiming to be smart home manufacturers. So, what exactly is a smar...[Details]
Permanent magnet synchronous motors (PMSMs), with their significant advantages such as high efficiency, high power density, excellent dynamic performance, and compact structure, have been widely us...[Details]