EEWORLDEEWORLDEEWORLD

Part Number

Search

LPP-150-13.5

Description
100W Single Output with PFC Function
File Size608KB,4 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet View All

LPP-150-13.5 Overview

100W Single Output with PFC Function

100W Single Output with PFC Function
Features :
LPP-100
series
Universal AC input / Full range
Built-in active PFC function
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
LPP-100-3.3 LPP-100-5
3.3V
20A
0 ~ 20A
66W
5V
20A
0 ~ 20A
100W
100mVp-p
LPP-100-7.5 LPP-100-12 LPP-100-13.5 LPP-100-15 LPP-100-24 LPP-100-27 LPP-100-48
7.5V
13.5A
0 ~ 13.3A
101.25W
100mVp-p
12V
8.5A
0 ~ 8.5A
102W
100mVp-p
13.5V
7.5A
0 ~ 7.5A
101.25W
100mVp-p
15V
6.7A
0 ~ 6.7A
100.5W
100mVp-p
24V
4.2A
0 ~ 4.2A
100.8W
150mVp-p
27V
3.8A
0 ~ 3.8A
102.6W
150mVp-p
48V
2.1A
0 ~ 2.1A
100.8W
250mVp-p
RIPPLE & NOISE (max.)
Note.2
100mVp-p
3.14 ~ 3.63V 4.75 ~ 5.5V
2.0%
2.0%
0.5%
1.0%
28ms/230VAC
0.5%
1.0%
7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
2.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
600ms, 30ms/230VAC
1200ms, 30ms/115VAC at full load
28ms/115VAC at full load
120 ~ 370VDC
PF>0.98/115VAC at full load
76%
79%
79%
80%
83%
83%
83%
0.75A/230VAC
VOLTAGE RANGE
Note.5
85 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
(Note 4)
PF>0.95/230VAC
69%
1.7A/115VAC
75%
COLD START 30A/230VAC
<2mA / 240VAC
105 ~ 150%
rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V 8.6 ~ 10.1V
13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V
55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
224.3Khrs min. MIL-HDBK-217F (25
222*62*32mm (L*W*H)
0.51Kg; 24pcs/13.9Kg/1.76CUFT
)
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:LPP-100-SPEC 2005-09-13
The 30m frequency communication circuit diagram for electronic competitions has been released
[i=s] This post was last edited by paulhyde on 2014-9-15 09:41 [/i] The chips we are going to use are: ET13X211 as the receiver and ET13X221 as the transmitter. The circuit is shown in the figureThe r...
njlianjian Electronics Design Contest
About the problem of transferring 4K program before 2440 booting from nand
Hello everyone! Today, when I was looking at the DS of 2440, I suddenly noticed a problem. If you start from NAND, the manual says to copy the first 4K in the flash to the steppingstone first, and the...
zhengjiewen Embedded System
Urgent, urgent, the 24v to 5v VICOR power module has no output?
Can someone help me solve the problem of the vicor module power supply not outputting? The situation is like this, the vicor module used is V24C5T50BG, and the sc end and the +out end are connected wi...
safegard Embedded System
How to use HyperTerminal to burn the BIN file generated by ADS1.2 into FLASH in S3C2410?
I am learning S3C2410 development board and I have a problem!! I want to burn the BIN file generated by ADS1.2 into FLASH, but I don't know how to do it! I use UART0 to connect the development board a...
lranseti Embedded System
I want to buy a notebook for drawing, please recommend
My current laptop is 10 years old, the optical drive is broken and it is very slow. I want to buy a new one now, hope you can recommend one. The main requirements are as follows: 1. Can use cadence16....
651076842 PCB Design
TI Reading: Op amp gain stability Part 2: DC gain error analysis
[i=s] This post was last edited by dontium on 2015-1-23 13:33 [/i] Op Amplifier Gain Stability Part 2: DC Gain Error Analysis...
安_然 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2596  1573  1064  1637  958  53  32  22  33  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号