Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
224.3Khrs min. MIL-HDBK-217F (25
222*62*32mm (L*W*H)
0.51Kg; 24pcs/13.9Kg/1.76CUFT
)
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:LPP-100-SPEC 2005-09-13
100W Single Output with PFC Function
Mechanical Specification
222
5
5
212
LPP-100
series
Unit:mm
CN2
1
62
52
CN1
5
4
3
2
1
F4A/250V
+V ADJ.
8
4-
3.5
AC Input Connector (CN1) : JST B5P-VH or equivalent
Pin No.
1
2,4
3
5
Assignment
AC/L
No Pin
AC/N
FG
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
32
DC Output Connector (CN2) : JST B8P-VH or equivalent
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 with cooling FAN(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A
191.8Khrs min. MIL-HDBK-217F (25
222*75*41mm (L*W*H)
0.62Kg; 24pcs/16.6Kg/1.39CUFT
)
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:LPP-150-SPEC 2006-10-18
150W Single Output with PFC Function
Mechanical Specification
222
5
212
LPP-150
series
Unit:mm
5
CN1
5
4
3
2
1
FG
1
CN2
75
65
AC FUSE
F5A/250V
12
+V ADJ.
4-
3.8
AC Input Connector (CN1) : JST B5P-VH or equivalent
Pin No.
1
2,4
3
5
Assignment
AC/L
No Pin
AC/N
FG
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
41
DC Output Connector (CN2) : JST B6P-VH*2 or equivalent