EEWORLDEEWORLDEEWORLD

Part Number

Search

LPS-100-15

Description
100W Single Output without PFC Function
File Size669KB,4 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet Compare View All

LPS-100-15 Online Shopping

Suppliers Part Number Price MOQ In stock  
LPS-100-15 - - View Buy Now

LPS-100-15 Overview

100W Single Output without PFC Function

50W Single Output Switching Power Supply
Features :
Universal AC input / Full range
LPS-50
series
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
Small and compact size
Built-in remote ON-OFF control
LED indicator for power on
100% full load burn-in test
Low profile:23mm thickness
2 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD(10sec.)
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
AC CURRENT
(Typ.)
115VAC
230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
PROTECTION
OVER VOLTAGE
FUNCTION
REMOTE ON/OFF
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
(Note 5)
LPS-50-3.3
3.3V
10A
0 ~ 12A
33W
Note.4
39.6W
LPS-50-5
5V
10A
0 ~ 12A
50W
60W
50mVp-p
4.5 ~ 5.5V
3.0%
1.0%
3.0%
LPS-50-12
12V
4.2A
0 ~ 5A
50.4W
60W
80mVp-p
10.8 ~ 13.2V
2.0%
1.0%
2.0%
LPS-50-15
15V
3.4A
0 ~ 4.1A
51W
61.5W
80mVp-p
13.5 ~ 16.5V
2.0%
1.0%
2.0%
LPS-50-24
24V
2.1A
0 ~ 2.5A
50.4W
60W
80mVp-p
21.6 ~ 27.2V
1.0%
1.0%
1.0%
LPS-50-48
48V
1.1A
0 ~ 1.3A
52.8W
62.4W
100mVp-p
43.2 ~ 52.8V
1.0%
1.0%
1.0%
RIPPLE & NOISE (max.)
Note.2
50mVp-p
3 ~ 3.6V
VOLTAGE TOLERANCE
Note.3
3.0%
1.0%
3.0%
100ms, 40ms/230VAC
70ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
75%
0.9A
0.6A
100ms, 40ms/115VAC at full load
12ms/115VAC at full load
127 ~ 370VDC
81%
1.2A
0.8A
35A/230VAC
82%
84%
85%
86%
COLD START 18A/115VAC
<1mA / 240VAC
122 ~ 160%
rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.04%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
27.6 ~ 32.4V
57.6 ~ 67.2V
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A
341.7Khrs min. MIL-HDBK-217F (25
195*55*23mm (L*W*H)
0.24Kg; 48pcs/12.5Kg/0.84CUFT
)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:LPS-50-SPEC 2006-04-13

LPS-100-15 Related Products

LPS-100-15 LPS-100-13.5 LPS-100-24 LPS-100-27 LPS-100-48 LPS-50-24 LPS-50-48
Description 100W Single Output without PFC Function 100W Single Output without PFC Function 100W Single Output without PFC Function 100W Single Output without PFC Function 100W Single Output without PFC Function 50W Single Output Switching Power Supply 50W Single Output Switching Power Supply
Cute comics about blood types
Regarding blood type determining personality, and horoscope predictions, I have always felt that these things are not very reliable. . . So, when the beautiful girls in the office discussed horoscopes...
songbo Talking
Problems with using SPI communication between two microcontrollers
The goal is to achieve SPI communication between two MCUs. Both MCUs are connected to the host computer. The goal is to send a character from host computer A to host computer B on the serial assistant...
Mr.Bubble MCU
Application xml under vxworks
I now have a project that requires the use of an XML parser under VxWorks. I have found several source files of libraries, libxml2 and tinyxml. I don't know how to compile the former under tornado, an...
hately6103 Real-time operating system RTOS
DIY hygrometer design ideas: STC12C2052+RS232 discrete parts+SHT2X
In fact, RS232 can also be easily used with discrete components, and the circuit is simpler, as shown in Figure 2:P1 port and some P3 ports can be used flexibly....
bjwl_6338 DIY/Open Source Hardware
The Right Choice for Embedded Real-Time System Development
As the complexity of embedded real-time systems increases, design engineers must carefully consider the synergy between software and hardware when defining and analyzing the initial requirements of th...
uh Embedded System
Which graphics card has better performance, Nvidia GeForce 7300 LE or Nvidia Geforce4 MX440 with AGP8x?
Which graphics card has better performance, Nvidia GeForce 7300 LE or Nvidia Geforce4 MX440 with AGP8x?...
suizhihen Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2829  469  981  1209  1530  57  10  20  25  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号