Description
5250 Power Control Series
File Size754KB,2 Pages
ManufacturerMRV Communications ( ADVA )
Websitehttps://www.advaoptical.com
Download Datasheet View All

LX-5250-16V1L30 Overview

5250 Power Control Series

Out-of-Band Networking
Datasheet
LX Series
5250 Power Control Series
The 5250 Power Control Series from MRV Communications delivers
AC power solutions combining intelligent power distribution and remote
power control. A key element of MRV’s Out-of-Band Network solutions,
is providing a powerful, cost-effective approach for remote networks
and systems to ensure minimal operational downtime and eliminate
site visits.
Applications
• Enterprise data centers
• Remote/branch offices
• Test and development labs
• Utilities
Simple, Secure Remote Network Operations
The 5250 Power Control Series allows administrators to remotely power-
on, power-off or reboot equipment and monitor power consumption.
The 5250 models are accessible through MRV’s LX Series Console
Servers with enhanced security capabilities, including SSH v2, SNMP V3,
Radius, SecurID, TACACS+, and are FIPS 140 certified. The LX Series
provides management through an easy to use browser-based GUI,
extensive command line interface, and MRV’s SNMP based MegaVision
management platform.
The LX Series features allows sophisticated site specific power
management automation. The Trigger/Action feature of the LX Series
allows site administrators to easily automate physical and security
infrastructure control. Additional applications include controlling power
access for lab automation, turning on additional air conditioning
when needed, or controlling individual power outlets by department or
scheduled activity.
Benefits
• Combine power distribution and remote power management
• Single management interface for service port management and
remote power control
• Easy to use graphical browser interface, Command Line Interface
and SNMP based management options
• Industry leading security features, including Radius, SecurID,
TACACS+, and more.
• Only remote power management vendor to support US
government FIPS 140 security standard.
Mobile
Access
Cent
ralized
Operations
Key Features
• Power cycle individual power outlets to remotely reboot servers
and network devices, anywhere in the world. Or, power-off
unused power receptacles
• High Power Distribution: 120V, 208V, 240V and three-phase
power options. 20 or 30-Amp power input feed
• 8, 16, 24 or 32 ports
• Vertical or horizontal mounting models
• Group outlets by name, within a unit, or across multiple units
• Access controlled through standard security infrastructure,
including Radius, SecurID, TACACS+, LDAP, or local database
• Power-up Sequencing: Prevent an in-rush power overload
• Input Current Monitor: Measure the aggregate current draw on
each power circuit monitor using LED digital display or remotely
• Automated alerts though SNMP, pager, SMS
Manage
d
Elements
Dial On
Demand
Private Net/Internet
Console
Server
S
Conta
ct
Sensors
~
Critical
Elements
Power
Management
sales@mrv. com
【Hanker M4】Chapter 9 IIC data readout LCD display
[i=s]This post was last edited by Changjianze1 on 2015-5-20 23:56[/i] [align=left][size=5][b]1. Introduction[/b][/size][/align][align=left][size=3]The previous few articles simply implemented the read...
常见泽1 Microcontroller MCU
Design of low-power photovoltaic grid-connected inverter based on DSP
[i=s]This post was last edited by paulhyde on 2014-9-15 03:38[/i][table=98%][tr][td]Author: Yang Jun and Jin Xinmin, Institute of New Energy, School of Electrical Engineering, Beijing Jiaotong Univers...
小人物 Energy Infrastructure?
Upload the information of two Launch Pads~
I'll upload two copies of launchpad information~~which is quite useful for beginners. ~...
fakeyee Microcontroller MCU
MCU peripheral chip PDF document
[i=s]This post was last edited by paulhyde on 2014-9-15 09:07[/i] Resource sharing....
黑白、灰 Electronics Design Contest
"Shazhanyou Boutique Series" has 11 books in total, PDG format
[b][size=4][color=black]Contains the following books: [/color][/size][/b][size=36pt][color=blue][size=4][color=black]★100 latest examples of multimeter applications★Analog and digital multimeter detec...
tiankai001 MCU
Please help -48V to +48V or +27v circuit
I need a -48V conversion circuit to convert -48 and neutral to neutral and +48 or +27V or other positive power supply. Note: The device is placed outdoors and the shell is grounded. Please do not swap...
tonytong Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2738  1231  1077  1087  2227  56  25  22  45  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号