EEWORLDEEWORLDEEWORLD

Part Number

Search

287XCXC218F240VAC

Description
Off-Delay Relay, 3PDT, Momentary, 2750mW (Coil), 10A (Contact), 28VDC (Contact), 18s, AC Input, AC/DC Output, Panel Mount
CategoryMechanical and electronic products    relay   
File Size557KB,4 Pages
ManufacturerStruthers-Dunn
Download Datasheet Parametric View All

287XCXC218F240VAC Overview

Off-Delay Relay, 3PDT, Momentary, 2750mW (Coil), 10A (Contact), 28VDC (Contact), 18s, AC Input, AC/DC Output, Panel Mount

287XCXC218F240VAC Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC):204 V
body width35.3 mm
Body length or diameter37.6 mm
Coil current (AC) maximum value0.011 A
Coil power2750 mW
Maximum coil voltage (AC)240 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
timed delay18 s
Manufacturer's serial number287
Installation featuresPANEL MOUNT
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
GuidelineUL
Relay actionMOMENTARY
Relay function3PDT
Relay typeOFF-DELAY RELAY
surface mountNO
Termination typeSOLDER
Base Number Matches1
286/287 Series - Squre Base Time Delay Relay
SPDT - 3PDT, 10 Amp
The 286 on delay and 287 off delay are square base, bladed versions of time delay relays. Both AC and
DC versions are available. On delays can have up to three poles. The timing circuit is a fully encapsulated
E13324 precision RC (resistor – capacitor) network typically used in applications where oscillators are not desired.
Fixed time and externally adjustable versions are available. The package on this series is typically socket
mounted. It can also be panel mounted allowing direct connections to terminals with quick-connects or
soldering.
GENERAL SPECIFICATIONS (@ 25° C)
Timing:
Functions Available
Time Range
Timing Adjustment
Timing Repeatability
(Constant voltage and temperature)
Reset Time maximum
Input Pulse Length minimum
Contacts:
Contact Configuration
Contact Material
Contact Rating
120 / 240VAC Resistive
28VDC Resistive
Motor 120VAC
Motor 240VAC
Minimum Contct Load
Contact Resistance, Initial
Coil:
Coils Available
Nominal Coil Power
Input Voltage Tolorance -AC
Input Voltage Tolorance -DC
Transient Protection
Reverse Polarity Protection
Duty
Dielectric Strength:
Across Open Contacts
Between Mutally Insulated Points
Insulation Resistance
Temperature:
Operating
Storage
Life Expectancy:
Electrical (full load operations)
Mechanical (no load operations)
Miscellaneous:
Mounting Position
Mating Socket
Enclosure
Weight
On-delay, Off-delay
Up to 300 seconds
Knob
3%
150mS
50mS
SPDT, DPDT, 3PDT
Silver Alloy
10 Amp / 10 Amp
10 Amp
1/3Hp
1/2Hp
500mW
100 milliohms max @ 6VDC, 1A
AC and DC
2.75VA 2W
85% to 110% of nominal
80% to 110% of nominal
Yes
Yes
Continuous
500Vrms
1500Vrms
1,000 Mohms min @ 500VDC
-20 to 70°C (-4 to 158°F)
-40 to 85°C (-40 to 185°F)
100,000
10,000,000
Any
SK-SQB11-DS
Clear Polycarbonate
5.0oz (142 grams)
7/11
www.struthers-dunn.com
(843) 664-3303
Part-time job
Is there anyone in Guangdong who can write PIC or Songhan microcontrollers? I have some small programs that need to be written by someone on a part-time basis. If you are interested, please leave your...
yealien Recruitment
Differential amplifier circuit
Differential amplifier circuit, if you need it, you can download it yourself, it's very good....
HONG哥 Analog electronics
Raspberry Pi Learning Notes 1: Intranet and Extranet
[b][b][font=宋体][size=22pt]Raspberry Pi Learning Notes 1: Intranet and Extranet[/size][/font][/b][/b][align=left][font=宋体]Because I learned Raspberry Pi before, I bought a peanut shell account on Oray,...
bqgup Creative Market
How to read mma8451 with msp430f149?
How to use msp430f149 to read mma8451?...
Lost Microcontroller MCU
Analysis of using optocouplers in switching power supplies
[size=4] There are a large number of devices in the switching power supply circuit, and most of them have complex structures. Optocouplers are one of them. The characteristics of optocouplers are smal...
qwqwqw2088 Analogue and Mixed Signal
How to read the segments space allocation of IAR compiler when programming
How to read the segments space allocation of the IAR compiler when programmingI want to directly display the compiler's built-in variable values such as CODE_I, CODE_ID, DATA_I, DATA_C in the program....
qlmiao stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2208  2186  2606  1457  538  45  44  53  30  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号