Part Number

Search

5424.9251.122

Description
Mains Power Connector
CategoryThe connector    The connector   
File Size677KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

5424.9251.122 Overview

Mains Power Connector

5424.9251.122 Parametric

Parameter NameAttribute value
MakerSCHURTER
Reach Compliance Codecompliant
Connector typeMAINS POWER CONNECTOR
Manufacturer's serial number54
Power Entry Modules with Line Filter
Felcom 54
www.schurter.com/pg06
Standard- or Medical-Filter
IEC Appliance Inlet C14 Modular Assembling Options
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuse-
holder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and
medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
Description
Characteristics
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Qualified for use in equipment according IEC/EN 60950
Approvals
Other versions on request
References
Weblinks
- VDE Certificate Number: 101307
- UL File Number: E72928
- Line switch with other rocker marking
Alternative: version without line filter Felcom 64
pdf, html, General Product Information, Approvals, RoHS, CHINA-RoHS,
Mating Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-
Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5
/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
F acc. to IEC/EN 60320-2-2,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard Version, IEC 60939, IEC
60601-1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical Details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
Connectors

void I2CMasterSpeedSet(unsigned long ulBase, unsigned long ulSpeed)
void I2CMasterSpeedSet(unsigned long ulBase, unsigned long ulSpeed) { unsigned long ulClk, ulTPR; ulClk = SysCtlClockGet() ); // Get the current system clock rate ulTPR = (ulClk / (2 * 10)) / ulSpeed;...
amy_shen Microcontroller MCU
It's the last day of another year.
Oh, year after year, how many years...
wangfuchong Talking
Power synthesis and magic T network
...
dontium RF/Wirelessly
The sensor driver for X-NUCLEO-IKS01A3 will soon be available in MakeCode
The sensor MakeCode drivers for the X-NUCLEO-IKS01A3 board that I wrote have been approved by MEF (Micro:bit Educational Foundation) and will soon be officially available in MakeCode. If you design re...
dcexpert ST Sensors & Low Power Wireless Technology Forum
【AT-START-F425 Review】 3. GPIO Lighting and Button Evaluation
The development board of Arty F425 feels quite close to development, the functions are relatively intuitive, and the codes are also intuitive. According to the evaluation progress, GPIO lighting and b...
kit7828 Domestic Chip Exchange
TMS320C6678 Development Routine User Manual Study 4
Check whether the emulator is installed successfully The following TMS320C6678 development uses the TL-XDS560V2 emulator as an example. Power off the development board, connect the emulator and the de...
火辣西米秀 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2702  846  1029  991  408  55  18  21  20  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号