EEWORLDEEWORLDEEWORLD

Part Number

Search

MVS21B12B

Description
WET REED RELAY, SPST, MOMENTARY, 0.036A (COIL), 5VDC (COIL), 179mW (COIL), 2A (CONTACT), 500VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size648KB,9 Pages
ManufacturerETC1
Download Datasheet Parametric View All

MVS21B12B Overview

WET REED RELAY, SPST, MOMENTARY, 0.036A (COIL), 5VDC (COIL), 179mW (COIL), 2A (CONTACT), 500VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT

MVS21B12B Parametric

Parameter NameAttribute value
Maximum operating temperature80 Cel
Minimum operating temperature-40 Cel
stateCONSULT MFR
sealEPOXY TERMINAL SEALED
Coil power179 mW
Relay actionMOMENTARY
Relay functionSPST
Coil resistance140 ohm
Electrical life2.00E8 Cycle(s)
Manufacturer SeriesDIP14
Maximum DC coil current0.0360 A
Maximum DC coil voltage5 V
Maximum AC contact current2 A
Maximum DC contact current2 A
Maximum AC contact voltage500 V
Maximum DC contact voltage500 V
DC coil operating voltage3.75 V
DC coil release voltage0.5000 V
width6.91 mm
high6.71 mm
length or diameter19.61 mm
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours1.75 ms
Relay typeWET REED RELAY
release time1.5 ms
Terminal typeSOLDER
SRC
DEVICES
DIP 14 SERIES REED RELAYS
MSS2
s
MSS7
s
PRMA
s
DSS7
s
PRME
s
MVS2
s
MVS7
DESCRIPTION
SRC Device’s epoxy molded DIP 14 Series offers a variety of contacts and schematics to meet the needs of a wide
range of applications. It features the MVS2/MVS7 models designed for high reliability. The MSS2/7 DIPs are
1-Form-A relays equipped with the MYAD
®
all-position mounting switch. With switching up to 50 Watts and a
4000V isolation option, the DIP 14 Series is a relay package that allows for automatic insertion directly on PCBs
as well as insertion into standard 14 Pin DIP sockets.
FEATURES
s
s
s
s
s
s
s
s
s
RATINGS (@ 25˚ C)
Parameter
Switching Voltage
PRMA/PRME/DSS7
PRMA Form C
MSS2/MSS7
MVS2/MVS7
Switching Current
PRMA/PRME/DSS7
PRMA Form C
MSS2/MSS7/MVS2/MVS7
Carry Current
PRMA/PRME/DSS7
PRMA Form C
MSS2/MSS7
MVS2/MVS7
Switching Frequency
PRMA/PRME/DSS7
PRMA Form C
MSS2/MSS7/MVS2/MVS7
Contact Resistance
PRMA/PRME/DSS7
PRMA Form C
MSS2/MSS7/MVS2/MVS7
(See detailed specifications for more information.)
All position mercury contacts on some models
Stable contact resistance over life
4000 Vac input-output isolation
Bounce free operation
High insulation resistance
Switching speed of 300Hz
Long life > 1 billion operations
Epoxy molded for automatic board processing
FCC68 compatible (MSS2 & MSS7)
Min
Typ
Max
Unit
200
100
500
1000
Volts
Volts
Volts
Volts
APPLICATIONS
s
s
s
s
s
s
s
s
0.5
0.25
2
Amps
Amps
Amps
Automatic test equipment
Process control
Industrial
Telecom
Datacom
High-end security systems
Signaling
Metering
2
0.4
3
3
Amps
Amps
Amps
Amps
500
50
200
Hz
Hz
Hz
APPROVALS
s
UL approval (DSS7 & PRMA)
s
EN 60950 certified (MVS7, DSS7 & MSS7)
s
CSA approval (PRMA)
150
200
100
mΩ
mΩ
mΩ
www.srcdevices.com
1
How Class D Audio Amplifiers Work
How Class D Audio Amplifiers Work...
lorant Analog electronics
Frugal October---My Frugal Shopping Experience
Haha, time flies, today is the last day of October. After a month of thinking, today I will talk about my money-saving shopping experience:1. Purchase of RC componentsThis type of component is general...
tiankai001 Buy&Sell
The bet between Lei Jun and Dong Mingzhu expires this year. Who will win and who will lose?
[align=center][/align] The 1 billion bet back then! It will expire soon. Now Xiaomi has not only mobile phones, but also smart homes. Now there is P2P. Ms. Dong still focuses on air conditioners, but ...
兰博 Talking
Camera manufacturers used by various brands of mobile phones and tablets
When doing industry research on mobile phone/tablet cameras, I found that for mobile phones of various brands, I can only find the pixel parameters of the camera, and it is difficult to find relevant ...
doodle Mobile and portable
~~Please teach me how to control the DC motor switch with I/O port~~
I use the IO port of the STC12C5204AD microcontroller to control the DC motor switch. The connection method is as shown in the circuit diagram. Use external interrupt 1 and low-level control. There is...
alien_duck Power technology
I downloaded the file of protel to pads tool, why can't the ddb2.exe file in it run?
I am used to using pads, but the company gave me a protel file. So I want to convert protel into pads file, so I downloaded the tool, but when I run the ddb2.exe file inside, it prompts: "cannot find ...
朗宇科技 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1346  1064  159  1942  1848  28  22  4  40  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号