EEWORLDEEWORLDEEWORLD

Part Number

Search

8144-211-4113-03

Description
D Subminiature Connector, 37 Contact(s), Male and Female, Solder Terminal, Plug-receptacle
CategoryThe connector    The connector   
File Size368KB,2 Pages
ManufacturerECS
Websitehttp://www.ecsxtal.com/
Download Datasheet Parametric View All

8144-211-4113-03 Overview

D Subminiature Connector, 37 Contact(s), Male and Female, Solder Terminal, Plug-receptacle

8144-211-4113-03 Parametric

Parameter NameAttribute value
MakerECS
Reach Compliance Codeunknown
Other featuresOTHER STACKING CONNECTOR: 37 CONTACTS, 4/C SHELL SIZE
Body/casing typePLUG-RECEPTACLE
Connector typeD SUBMINIATURE CONNECTOR
Contact point genderMALE AND FEMALE
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
insulator materialGLASS FILLED POLYBUTYLENE TEREPHTHALATE-POLYESTER
MIL complianceNO
Mixed contactsNO
Installation typeBOARD AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceCHROMATE
Shell materialSTEEL
Housing size4/C
Termination typeSOLDER
Total number of contacts37
UL Flammability Code94V-0
CC
S
SPECIFICATIONS
8100 Series D-Subminiature
Dual Port Connector
CONTACT POSITIONS
09 Plug
15 Plug
25 Plug
37 Plug
A
.666 [16.92]
.994 [25.25]
1.534 [38.96]
2.182 [55.42]
B
.984 [25.00]
1.312 [33.32]
1.852 [47.04]
2.500 [63.50]
C
1.213 [30.80]
1.543 [39.20]
2.091 [53.10]
2.732 [69.40]
D
.329 [8.36]
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Brass or Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Shell: Steel, 100µ” Tin over 50µ” min. Nickel.
Clinch Nut: Brass, 100µ” min. Nickel Plated.
Boardlock: Brass, 100µ” min. Nickel Plated.
Screwlock: Brass, 100µ” min. Nickel Plated.
Current Rating: 3 amp at 30°C
Voltage Rating: 250 VAC/rms 60Hz
Contact Resistance: 20 m
max. At 1AMP DC.
Insulation Resistance: 1000 M
at 500 VDC.
Dielectric Withstand Voltage:
1500 V AC/rms 60Hz for 1 minute.
09 Rec.
15 Rec.
25 Rec.
37 Rec.
.642 [16.30]
.969 [24.60]
1.508 [38.30]
2.157 [54.80]
.984 [25.00]
1.312 [33.32]
1.852 [47.04]
2.500 [63.50]
1.213 [30.80]
1.543 [39.20]
2.091 [53.10]
2.732 [69.40]
.311 [7.90]
Dimensions are in inch [mm]
STACK HEIGHT
1
2
3
E
0.625 [15.88]
0.750 [19.05]
0.900 [22.86]
F
1.119 [28.42]
1.244 [31.60]
1.394 [35.41]
R
C
R
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
81 X X
-
X X X
-
X X X X
-
XX
SERIES NO.
CONTACT TYPE (top)
1
= 9
2
= 15
3
= 25
4
= 37
03
=
05
=
10
=
20
=
30
=
PART NUMBERING
CONTACT PLATING
Mating
Gold Flash
Gold Flash
10µ” Au
15µ” Au
30µ” Au
Tail
Gold Flash
100µ” SnPb
100µ” SnPb
100µ” SnPb
100µ” SnPb
CONTACT TYPE (bottom)
1
= 9
2
= 15
3
= 25
4
= 37
SHELL PLATING
1
= Tin (Standard)
2
= Nickel
3
= Chromate
CONNECTOR TYPE
1
=
2
=
3
=
4
=
Plug / Plug
Plug / Receptacle
Receptacle / Recptacle
Receptacle / Plug
INSULATOR COLOR
1
= Black (Standard)
2
= Blue
3
= White
STACK HEIGHT
DIMENSION
“E”
1
= 0.625” [15.88 mm]
2
= 0.750” [19.05 mm]
3
= 0.900” [22.86 mm]
BOARD MOUNTING OPTIONS
1
= L-Shape Support
2
= Dual Arrowhead Boardlock
3
= Quad Arrowhead Boardlock
FLANGE MOUNTING OPTIONS
1
=
2
=
3
=
4
=
5
=
6
=
7
=
8
=
ø .120” [3.05 mm] Hole
#4-40 Threaded Hole
#4-40 Threaded Hole With #4-40 UNC Screwlock Installed
#4-40 Threaded Hold With #4-40 UNC Screwlock Bulk-Packed
M3 Thread Hole
M3 Thread Hole With M3 Screwlock Installed
M2.6 Thread Hole
M2.6 Thread Hole With M2.6 Screwlock Installed
CONNECTOR VERSION
1=
Dual Port
WWW.ECSCONN.COM
What is the entry point for an inf file that has no DefaultInstall section?
The Internet says that the entry points of inf files are the Install section and the DefaultInstall section, but I can't find these two sections on many driver files. What is the entry point of the in...
小马哈 Embedded System
[National Technology N32 MCU Development Package] --N32G031 Series
[i=s]This post was last edited by milafan on 2022-5-10 17:56[/i]Go to the official website of National Technology - Developer Community - Download to download the latest information[attach]605017[/att...
milafan Domestic Chip Exchange
If signal modulation was like this back then, would you still not be able to learn it?
In previous articles, we have talked about the beauty of electromagnetic waves many times, but can we communicate with electromagnetic waves? No, we need to load information onto electromagnetic waves...
btty038 RF/Wirelessly
Components Science Popularization: Pressure Sensor
[size=4][color=#000000][backcolor=white]Pressure sensors are generally used to measure the pressure of fluids (such as liquids, gases, and melts). They have good mechanical processing and heat treatme...
fish001 Analogue and Mixed Signal
Question: How to accurately measure the duty cycle of a 100MHZ square wave? Thank you!
Question: How to accurately measure the duty cycle of a 100MHZ square wave? Thank you!...
book1 FPGA/CPLD
About uc/os-ii task switching and clock beat issues!
When a high-priority task is found in the ready list, OS_TASK_SW() is called to switch the task level. If a high-priority task suddenly appears while a low-priority task is running, when will the high...
szcharle Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 469  142  745  1129  839  10  3  15  23  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号