EEWORLDEEWORLDEEWORLD

Part Number

Search

59112-R40-22P037

Description
Board Connector, 44 Contact(s), 2 Row(s), Male, Straight, 0.079 inch Pitch, Solder Terminal, Black Insulator
CategoryThe connector    The connector   
File Size203KB,2 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

59112-R40-22P037 Overview

Board Connector, 44 Contact(s), 2 Row(s), Male, Straight, 0.079 inch Pitch, Solder Terminal, Black Insulator

59112-R40-22P037 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerAmphenol
Reach Compliance Codecompliant
ECCN codeEAR99
body width0.157 inch
subject depth0.146 inch
body length1.732 inch
Connector typeBOARD CONNECTOR
Contact completed and terminatedMatte Tin (Sn)
Contact point genderMALE
Contact materialCOPPER ALLOY
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Dielectric withstand voltage650VAC V
Insulation resistance1000000000 Ω
Insulator colorBLACK
insulator materialTHERMOPLASTIC
JESD-609 codee3
Manufacturer's serial number59112
Plug contact pitch0.079 inch
Match contact row spacing0.079 inch
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.0066 mm
Plating thickness15u inch
Rated current (signal)2 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.098 inch
Terminal pitch2.0066 mm
Termination typeSOLDER
Total number of contacts44
w wcadmin
Guo-Min Sun
-
Rick Bian
2010/10/31
2013/12/12
-
2013/12/12
ELX-N-16500-1
Released
N
PDS: Rev :N
STATUS:Released
Printed: Dec 12, 2013
Design of Fully Digital Single-phase Three-level Rectifier Control Circuit
Abstract: Three-level rectifiers have attracted more and more attention due to their unique advantages. The working principle of three-level bridge rectifiers is introduced, and its control system is ...
zbz0529 Power technology
51 MCU timer initial value setting problem
I just came into contact with and learned 51. I saw that some timer initial value settings are TH0=(65536-50000)/256; TL0=(65536-50000)%256; some are TH0=0FCH TL0=66H. What is the difference between t...
zjjone1023 51mcu
44b0 How to write FIQ interrupt? Why do I still have an interrupt vector after 0x1c in my interrupt vector table?
1. How to write 44b0 FIQ interrupt? 2. Why is there still an interrupt vector after 0x1c in my interrupt vector table? How does this work? b InitialReg b Error_ISR b Error_ISR b Error_ISR b Error_ISR ...
weizhou Embedded System
Share the National University Mecha Masters Competition I watched yesterday
[i=s]This post was last edited by 寒冰翼love on 2019-8-9 17:32[/i]Yesterday, I went to watch the group stage of the 5th National University Mech Masters Competition in Shenzhen. Unfortunately, I didn’t h...
寒冰翼love Robotics Development
Learn to deal with several issues of power supply EMI - absolutely on point, with pictures and text
Learn to deal with several issues of power supply EMI - absolutely on point, with pictures and text :loveliness:High download rate... If you think it's good, give it a thumbs up, so that more people w...
czf0408 Power technology
Question: What does the linear address in cache mean?
As title...
converter Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1482  2175  402  1693  1544  30  44  9  35  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号