DISCRETE SEMICONDUCTORS
DATA SHEET
handbook, halfpage
M3D373
BGY120A; BGY120B
UHF amplifier modules
Objective specification
1997 Nov 11
Philips Semiconductors
Objective specification
UHF amplifier modules
FEATURES
•
Single 3.5 V nominal supply voltage
•
1 W output power
•
Easy control of output power by DC voltage
•
Very high efficiency (typ. 60%)
•
Silicon bipolar technology
•
Standby current less than 10
µA.
APPLICATIONS
•
Hand-held transmitting equipment operating in the
824 to 849 MHz and 872 to 905 MHz frequency ranges.
DESCRIPTION
The BGY120A and BGY120B are two-stage UHF amplifier
modules in a SOT482B package with plastic cover. Each
module consists of two NPN silicon planar transistor dies
mounted together with a matching and bias circuit
components on a metallized ceramic substrate.
These modules produce an output power of 1 W into a
load of 50
Ω
with an RF drive power of 5 mW.
PINNING - SOT482B
PIN
1
2
3
4
5
BGY120A; BGY120B
DESCRIPTION
RF input
V
C
V
S
RF output
flange connected to ground
handbook, halfpage
5
4
3
2
1
MBK201
Bottom view
Fig.1 Simplified outline
QUICK REFERENCE DATA
RF performance at T
mb
= 25
°C.
TYPE
BGY120A
BGY120B
MODE OF
OPERATION
CW
CW
f
(MHz)
824 to 849
872 to 905
V
S
(V)
3.5
3.5
P
L
(W)
1
1
G
p
(dB)
≥23
≥23
η
(%)
typ. 60
typ. 60
Z
S
; Z
L
(Ω)
50
50
1997 Nov 11
2
Philips Semiconductors
Objective specification
UHF amplifier modules
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 134).
SYMBOL
V
S
V
C
P
D
P
L
T
stg
T
mb
DC supply voltage
DC control voltage
input drive power
load power
storage temperature
operating mounting-base temperature
PARAMETER
−
−
−
−
−40
−30
BGY120A; BGY120B
MIN.
5
MAX.
V
V
2.9
10
1.4
+100
+100
UNIT
mW
W
°C
°C
CHARACTERISTICS
Z
S
= Z
L
= 50
Ω;
P
D
= 5 mW; V
S
= 3.5 V; V
C
≤
2.5 V; T
mb
= 25
°C;
unless otherwise specified.
SYMBOL
f
PARAMETER
frequency range
BGY120A
BGY120B
I
Q
I
C
P
L
G
p
η
H
2
H
3
VSWR
in
total leakage current
control current
load power
power gain
efficiency
second harmonic
third harmonic
input VSWR
stability
V
C
= 2.5 V
V
S
= 3.2 V; T
mb
= 85
°C
adjust V
C
for P
L
= 1 W
V
S
= 3.2 V;
adjust V
C
for P
L
= 0.9 W
adjust V
C
for P
L
= 0.9 W
adjust V
C
for P
L
= 0.9 W
adjust V
C
for P
L
= 0.9 W
V
C
≤
0.5 V
P
L
≤
1.4 W; V
C
= 0 to 2.9 V;
V
S
= 2.8 to 5 V; P
D
= 4 to 10 dBm;
VSWR
≤
6 : 1 through all phases
V
C
≤
0.5 V
adjust V
C
for P
L
= 1 W;
bandwidth = 30 kHz;
f
n
= f
o
+ 45 MHz
P
Tx
= 0.9 W; f
int
= f
Tx
−
45 MHz;
P
int
= P
Tx
−
30 dB; note 1
V
S
= 5 V;
adjust V
C
for P
L
= 1.4 W;
VSWR
≤
10 : 1 through all phases
V
C
= 0.3 V; P
D
<
−60
dBm
824
872
−
−
1
0.71
23
55
−
−
−
−
−
−
−
−
−
−
−
−
60
−
−
−
−
−
849
905
10
10
−
−
−
−
−35
−40
2:1
4:1
−60
dBc
MHz
MHz
µA
mA
W
W
dB
%
dBc
dBc
CONDITIONS
MIN.
TYP.
MAX.
UNIT
isolation
P
n
noise power
−
−
-40
−
−
−90
dBm
dBm
d
im
reverse intermodulation
ruggedness
−
−
−8
dB
no degradation
Note
1. With respect to P
int
.
1997 Nov 11
3
Philips Semiconductors
Objective specification
UHF amplifier modules
PACKAGE OUTLINE
BGY120A; BGY120B
PACKAGE
OUTLINE
NOT
RELEASED
FOR
GENERAL
PUBLICATION
1997 Nov 11
4
Philips Semiconductors
Objective specification
UHF amplifier modules
DEFINITIONS
Data Sheet Status
Objective specification
Preliminary specification
Product specification
Limiting values
BGY120A; BGY120B
This data sheet contains target or goal specifications for product development.
This data sheet contains preliminary data; supplementary data may be published later.
This data sheet contains final product specifications.
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or
more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation
of the device at these or at any other conditions above those given in the Characteristics sections of the specification
is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices, or systems where malfunction of these
products can reasonably be expected to result in personal injury. Philips customers using or selling these products for
use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such
improper use or sale.
1997 Nov 11
5