Tantalum Surface Mount Capacitors – MIL-PRF (CWR Series)
Table 1 – T409 Series CWR09 Style MIL-PRF 55365/4, Ratings & Part Number Reference
Rated
Voltage
85ºC
VDC
4
4
4
4
4
4
4
4
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
25
25
25
VDC
85ºC
Rated
Cap
120Hz
µF
2.2
4.7
6.8
10
15
33
68
100
1.5
3.3
4.7
6.8
10
22
47
68
1
2.2
3.3
4.7
6.8
15
33
47
0.68
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
6.8
15
22
0.33
0.68
1
µF
120Hz
Case Code/
Case Size
KEMET/EIA
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T409A225(1)004(2)(3)(4)
T409B475(1)004(2)(3)(4)
T409C685(1)004(2)(3)(4)
T409D106(1)004(2)(3)(4)
T409E156(1)004(2)(3)(4)
T409F336(1)004(2)(3)(4)
T409G686(1)004(2)(3)(4)
T409H107(1)004(2)(3)(4)
T409A155(1)006(2)(3)(4)
T409B335(1)006(2)(3)(4)
T409C475(1)006(2)(3)(4)
T409D685(1)006(2)(3)(4)
T409E106(1)006(2)(3)(4)
T409F226(1)006(2)(3)(4)
T409G476(1)006(2)(3)(4)
T409H686(1)006(2)(3)(4)
T409A105(1)010(2)(3)(4)
T409B225(1)010(2)(3)(4)
T409C335(1)010(2)(3)(4)
T409D475(1)010(2)(3)(4)
T409E685(1)010(2)(3)(4)
T409F156(1)010(2)(3)(4)
T409G336(1)010(2)(3)(4)
T409H476(1)010(2)(3)(4)
T409A684(1)015(2)(3)(4)
T409B155(1)015(2)(3)(4)
T409C225(1)015(2)(3)(4)
T409D335(1)015(2)(3)(4)
T409E475(1)015(2)(3)(4)
T409F106(1)015(2)(3)(4)
T409G226(1)015(2)(3)(4)
T409H336(1)015(2)(3)(4)
T409A474(1)020(2)(3)(4)
T409B684(1)020(2)(3)(4)
T409B105(1)020(2)(3)(4)
T409C155(1)020(2)(3)(4)
T409D225(1)020(2)(3)(4)
T409E335(1)020(2)(3)(4)
T409F685(1)020(2)(3)(4)
T409G156(1)020(2)(3)(4)
T409H226(1)020(2)(3)(4)
T409A334(1)025(2)(3)(4)
T409B684(1)025(2)(3)(4)
T409C105(1)025(2)(3)(4)
(see below for
part options)
MIL-C-55365/4F
Part Number
(See below for
part options)
CWR09C(3)225(1)(2)(5)
CWR09C(3)475(1)(2)(5)
CWR09C(3)685(1)(2)(5)
CWR09C(3)106(1)(2)(5)
CWR09C(3)156(1)(2)(5)
CWR09C(3)336(1)(2)(5)
CWR09C(3)686(1)(2)(5)
CWR09C(3)107(1)(2)(5)
CWR09D(3)155(1)(2)(5)
CWR09D(3)335(1)(2)(5)
CWR09D(3)475(1)(2)(5)
CWR09D(3)685(1)(2)(5)
CWR09D(3)106(1)(2)(5)
CWR09D(3)226(1)(2)(5)
CWR09D(3)476(1)(2)(5)
CWR09D(3)686(1)(2)(5)
CWR09F(3)105(1)(2)(5)
CWR09F(3)225(1)(2)(5)
CWR09F(3)335(1)(2)(5)
CWR09F(3)475(1)(2)(5)
CWR09F(3)685(1)(2)(5)
CWR09F(3)156(1)(2)(5)
CWR09F(3)336(1)(2)(5)
CWR09F(3)476(1)(2)(5)
CWR09H(3)684(1)(2)(5)
CWR09H(3)155(1)(2)(5)
CWR09H(3)225(1)(2)(5)
CWR09H(3)335(1)(2)(5)
CWR09H(3)475(1)(2)(5)
CWR09H(3)106(1)(2)(5)
CWR09H(3)226(1)(2)(5)
CWR09H(3)336(1)(2)(5)
CWR09J(3)474(1)(2)(5)
CWR09J(3)684(1)(2)(5)
CWR09J(3)105(1)(2)(5)
CWR09J(3)155(1)(2)(5)
CWR09J(3)225(1)(2)(5)
CWR09J(3)335(1)(2)(5)
CWR09J(3)685(1)(2)(5)
CWR09J(3)156(1)(2)(5)
CWR09J(3)226(1)(2)(5)
CWR09K(3)334(1)(2)(5)
CWR09K(3)684(1)(2)(5)
CWR09K(3)105(1)(2)(5)
(See below for
part options)
DC
Leakage
µAmps +20ºC
max/5min
0.1
0.2
0.3
0.4
0.6
1.3
2.7
4.0
0.1
0.2
0.3
0.4
0.6
1.4
3.0
4.3
0.1
0.2
0.3
0.5
0.7
1.5
3.3
4.7
0.1
0.2
0.3
0.5
0.7
1.5
3.3
5.0
0.1
0.1
0.2
0.3
0.4
0.7
1.4
3.0
4.4
0.1
0.2
0.3
max/5min
µAmps +20ºC
DF
+20ºC 120Hz
% Max
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
% Max
+20ºC 120Hz
ESR
+20ºC 100kHz
Ohms
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
5.5
4.5
3.5
2.2
1.1
0.9
10.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
10.0
12.0
6.0
5.0
4.0
2.4
1.1
0.9
15.0
7.5
6.5
Ohms
+20ºC 100kHz
Moisture
Sensitivity
Temp≤260ºC
J-STD-020D
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
J-STD-020D
Temp≤260ºC
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
MIL-C-55365/4F
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ± 20%, K for ± 10%, or J for ± 5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert B (0.1%/1000Hrs), C (0.01%/1000Hrs), D (0.001%/1000Hrs) or A = N/A. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, or C = -55°C +85°C before Weibull. Designates Surge current
option.
Refer to Ordering Information for additional detail.
When using alarm() to set a timer, if the system time is changed, there will be a series of problems with recalculating the time. Is there such a signal to notify "the LINUX system time has been chang...
What if I want to fix the network address of this Zigbee module during development so that the module can run with this specified network address after connecting to the network?...
C8051F310 In-System Flash Programming
When using a single-chip microcomputer, some data needs to be set so that it will not be lost when the power is off. Generally, the first thing that comes to mind...
[i=s]This post was last edited by paulhyde on 2014-9-15 09:01[/i] 2008 Intel Cup Undergraduate Electronic Design Competition - Embedded System Special Invitational Competition, first prize works: Part...
introduction
As “energy conservation and emission reduction” has become an indicator of the National Economic Development Outline of the 11th Five-Year Plan, people’s awareness of green enviro...[Details]
In the scorching summer, electric fans are a must-have for cooling down people's homes. However, I believe most people have encountered this situation: the fan is plugged in, the switch is pressed,...[Details]
Laird Thermal Systems has introduced the HiTemp ET series Peltier cooler modules, which can operate at high temperatures and provide on-site cooling for sensitive electronic devices.
Dig...[Details]
Industrial computers with GPUs leverage powerful parallel processing to build deep learning models to analyze and respond to optical inputs. The systems develop an understanding of visual data to i...[Details]
Compared to cloud databases, minicomputers are purpose-built for decentralized, rugged computing at the edge of the network. By moving applications, analytics, and processing services closer to the...[Details]
Magna's integrated in-cabin perception system fuses vision and millimeter-wave radar data to detect the presence of passengers, identify stranded children, monitor driver fatigue and vital signs, a...[Details]
A patent disclosed by Ford proposes replacing traditional segmented side curtain airbags with integrated full-width side curtain airbags that span the side of the vehicle and can be deployed simult...[Details]
Common methods for troubleshooting roller press bearing wear include repair welding, thermal spraying, brush plating, and scrapping and replacement. However, these methods are often subject to asse...[Details]
For new energy vehicles, the importance of batteries is unquestionable. Not only does it determine the performance of the vehicle, but the battery density also has a great relationship with the veh...[Details]
introduction
A common voltage regulator is a three-terminal one. Its function is to step down the voltage and stabilize it at a fixed output value. Voltage regulators are commonly available in...[Details]
The automotive driveshaft is a crucial connecting component in the automotive mechanical system. It is a circular component that allows for connection or assembly, as well as movement and rotation....[Details]
In the wave of electrification and intelligence in the automotive industry, the E/E architecture is transitioning from distributed to domain control and then to regional architecture.
Th...[Details]
As in-vehicle audio and video entertainment features become increasingly diverse, the demand for digital transmission of audio and video information is urgent. Traditional protocols such as IEEE 13...[Details]
Amid the rapid advancement of automotive intelligence, on-board storage has become a thorny bottleneck restricting the "large-scale popularization" of advanced assisted driving.
On the o...[Details]
The term "remote meter reading" literally emphasizes remoteness. But how far is remote? One kilometer? Two kilometers? Those aren't considered far at all. Currently, the longest distance for ...[Details]