EEWORLDEEWORLDEEWORLD

Part Number

Search

328303D012

Description
Electromechanical Relay, 3PDT, 15VDC (Coil), 25A (Contact), 28VDC (Contact), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size355KB,4 Pages
ManufacturerSTPI Siege Social
Download Datasheet Parametric View All

328303D012 Overview

Electromechanical Relay, 3PDT, 15VDC (Coil), 25A (Contact), 28VDC (Contact), Random, AC/DC Output

328303D012 Parametric

Parameter NameAttribute value
MakerSTPI Siege Social
Reach Compliance Codeunknown
ECCN codeEAR99
body width26 mm
body height25.7 mm
Body length or diameter26 mm
Coil operating voltage (DC)10 V
Coil release voltage (DC)0.7 V
Coil resistance70 Ω
Maximum coil voltage (DC)15 V
Nominal coil voltage12 V
Coil/Input Power TypeDC
Contact (AC) maximum rated load I15A@115VAC
Contact (AC) maximum rated R load25A@115VAC
Maximum contact current (AC)25 A
Maximum contact current (DC)25 A
Contact (DC) maximum rated R load25A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Dielectric strength between breaking contacts1250 Vrms
Electrical life50000 Cycle(s)
Input switching control typeRandom
Insulation resistance100000000 Ω
Number of terminals11
operating hours10 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB hole count11
physical size26mm x 26mm x 25.7mm
Relay style3 FORM C
Relay function3PDT
release time10 ms
sealHERMETICAL
Terminal length0.0071 inch
Termination typeSOLDER
weight97 g
328 3
RT -
3
PDT
/25
A
RELAIS HERMETIQUES
MONOSTABLES
HERMETICALLY SEALED
NON LATCHING
RELAY
CARACTERISTIQUES GENERALES
GENERAL CHARACTERICS
Combinaison des contacts
Contact arrangement
3 RT
3PDT
Pouvoir de coupure 28 Vcc - 1 5 V/400 Hz
1
Contact rating 28 Vdc - 115 V/400 Hz
Circuit résistif
Resistive load
25 A
25 Amps
Circuit inductif (L/R = 5 ms)
Inductive load (L/R = 5 ms)
1 A (28 Vc) / 1 A (1 5 V - 400 Hz)
2
5
1
12 Amps (28 Vdc) / 15 Amps (115 V - 400 Hz)
Circuit moteur
Motor load
10 A
10 Amps
Circuit lampe
Lamp load
5A
5 Amps
Alimentation
Supply
Courant continu (polarisé) ou alternatif 400Hz
Direct current (polarised) or alternative current 400 Hz
Masse
Weight
85 g à 97 g max.
85 g to 97 g max.
Normes applicables en annexe
See appendice for applicable specifications
ENVIRONNEMENT
ENVIRONMENT
Température de fonctionnement
Temperature range
- 65° à + 1
25°C
- 65° to + 125°C
Position de fonctionnement
Operating position
Indifférente
Any
Tenue aux vibrations
Resistance against vibrations
Sinus : 30 g - 10 - 3 000 Hz / Aléatoire : 0,4 g
2
/Hz - 50 - 2 000 Hz
Sinus : 30 g - 10 - 3 000 Hz / Random : 0,4 g
2
/Hz - 50 - 2 000 Hz
Tenue aux chocs
Shocks resistance
200 g - 6 ms / 100 g - 1 ms
1
200 g - 6 ms / 100 g - 11 ms
Tenue aux secousses
Shake resistance
40 g
40 g
Accélération
Acceleration
20 g
20 g
Taux de fuite
Leak rate
< 1.10
-8
cm
3
/sec
< 1.10
-8
cm
3
/sec
58 Av. Claude VELLEFAUX - 75010 PARIS - FRANCE
328 1/4
63
Tel : 33.(0)1.42.03.94.20 - Fax : 33.(0)1.42.03.52.85 - www.stpigroup.com
[Lao Gao recommends] A batch of excellent books
[align=center][/align] I have recently compiled a batch of classic books and recommend them to you. I hope you will like them! 1. Tool books: "[url=https://download.eeworld.com.cn/detail/tyw/298077]El...
高进 Download Centre
The Dead Princess' Peacock Dance
I am listening to a music disc. If you want to listen to a song with the same title found online in high definition, please go to this website: [url=http://www.tudou.com/programs/view/TSrw1pM4Xg4/]htt...
wangfuchong Talking
Program upgrade example
I saw a post about upgrading on a certain website, and it actually costs several points, so I wrote a post here DiscussiononMSP430 program upgrade methodKey Laboratory of Optoelectronics, Ocean Univer...
dudu404 Microcontroller MCU
What is the use of harmonic distortion and third-order intermodulation of op amps?
[backcolor=rgb(239, 245, 249)] What do these op amp diagrams mean? What guidance do they have? [/backcolor]...
caijianfa55 Analog electronics
DSP interrupt system and its application
1 Interrupt Overview1.1 Interrupt Response Mechanism and ClassificationWhen the CPU is processing a normal program, it is sometimes required to process tasks with higher requirements, so it has to int...
fish001 DSP and ARM Processors
How to repair a broken power adapter
How to repair a broken power adapter? First, we need to check where the problem is. If it is a line fault, it includes power cord damage and no power, contact port oxidation and poor contact. Focus on...
木犯001号 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 377  441  2396  2817  523  8  9  49  57  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号