The EN60950 (intended for office automation equipment)
conforms with a 3mm
.118inch
gap.
When directly opening or closing the primary power supply side,
a contact gap of at least 3mm
.118inch
is required in order to
ensure safety.
19
J8(AJ8)
ORDERING INFORMATION
Ex.
AJ8
W
1
0
0
W
W
T
Type of
Size of handle
switch
AJ7: J8
Nil: Standard size
switch
(10 mm
.394inch)
W: Wide size
(19 mm
.748 inch)
Poles
Terminal shape
Actuator indication
0:
1:
2:
O
I
Actuator color*
W: White
B: Black
R: Red
Z: Dark gray
H: Light gray
L: Blue
G: Green
Y: Yellow
Flang color*
Nil: Black
(W: White)
(R: Red)
(Z: Dark gray)
(H: Light gray)
(L: Blue)
(G: Green)
(Y: Yellow)
Insulation guard
Nil: Short guard
type
T: Long guard
type (.250
Quick-connect
terminal and
soldering
terminal of
standard size
only)
1: Single pole 0: .250 Quick-
2: Double pole
connect terminal
1: Soldering
terminal
2: PC board
terminal
3: PC board right
andle terminal
4: PC board left
angle terminal
O
I
Remarks: 1. Please consult us for details concerning different flange colors.
2. “I
O”
is engraved on all flanges.
3. The color of
I O
indication on the actuator:
• White actuator: black
• Others: white
PRODUCT TYPES
1. Standard actuator type
(1) Without indication on actuators
Terminal shape
.250 Quick-connect terminal
Soldering terminal
PC board terminal
PC board right angle terminal
PC board left angle terminal
Poles
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Poles
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
ON-OFF
Operating types
With
| O
indication
AJ8101*
AJ8201*
AJ8111*
AJ8211*
AJ8121*
AJ8221*
AJ8131*
AJ8231*
AJ8141*
AJ8241*
ON-OFF
Operating types
Without indication
AJ8100*
AJ8200*
AJ8110*
AJ8210*
AJ8120*
AJ8220*
AJ8130*
AJ8230*
AJ8140*
AJ8240*
With
— O
indication
AJ8102*
AJ8202*
AJ8112*
AJ8212*
AJ8122*
AJ8222*
AJ8132*
AJ8232*
AJ8142*
AJ8242*
(2) With
| O
indication on actuators
Terminal shape
.250 Quick-connect terminal
Soldering terminal
PC board terminal
PC board right angle terminal
PC board left angle terminal
(Standard flange color is black. For other colors type, they are custom ordered.)
Remarks: 1. A letter indicating the actuator color is entered in place of * symbol. (W: White B: Black R: Red Z: Dark gray H: Light gray L: Blue G: Green
Y: Yellow)
For requests of other flange color,please suffix following letter. (W: White R: Red Z: Dark gray H: Light gray L: Blue G: Green Y: Yellow)
2. Long guard type is available for .250 Quick-connect terminal and soldering terminal type.
When ordering, please suffix T.
3. The color of
| O
indication on the actuator:
White actuator: black Others: white
4. They come with a stamp indicating international standards without your request.
5. Note that the position of the
|
mark on the flange is used as a reference for left angle and right angle units as shown in the diagram below.
I
mark
I
mark
Right angle terminal
Left angle terminal
20
J8(AJ8)
2.Wide actuator type
(1) Without indication on actuators
Terminal shape
.250 Quick-connect terminal
Soldering terminal
PC board terminal
Poles
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Poles
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
ON-OFF
Operating types
ON-OFF
Operating types
Without indication
AJ8W100*
AJ8W200*
AJ8W110*
AJ8W210*
AJ8W120*
AJ8W220*
With
| O
indication
AJ8W101*
AJ8W201*
AJ8W111*
AJ8W211*
AJ8W121*
AJ8W221*
With
— O
indication
AJ8W102*
AJ8W202*
AJ8W112*
AJ8W212*
AJ8W122*
AJ8W222*
(2) With
| O
indication on actuators
Terminal shape
.250 Quick-connect terminal
Soldering terminal
PC board terminal
(Standard flange color is black. For other colors type, they are custom ordered.)
Remarks: 1. A letter indicating the actuator color is entered in place of * symbol. (W: White B: Black R: Red Z: Dark gray H: Light gray L: Blue G: Green
Y: Yellow)
For requests of other flange color,please suffix following letter. (W: White R: Red Z: Dark gray H: Light gray L: Blue G: Green Y: Yellow)
2. The color of
| O
indication on the actuator:
White actuator: black Others: white
3. They come with a stamp indicating international standards without your request.
SPECIFICATIONS
1. Contact rating
Type
J8 switch
Voltage
AC 250V
Resistive load
(cos
φ
]
1.0)
16A
Motor load
(EN61058-1)
(cos
φ
]
0.6)
4A
Remark: The motor load is in accordance with EN61058-1. Inlush current can be switched up to the value of 6 times the indicated rating.
2. Characteristics
Expected life
(Min. operations)
Initial insulation resistance
(Between terminals)
Initial breakdown voltage
(Between terminals)
Initial contact resistance
(By voltage drop at 1A, 2 to 4V DC)
Temperature rise
Vibration resistance
Shock resistance
Actuator strength
Tensile terminal strength
Ambient temperature
Ambient humidity
Flame retardancy
Tracking resistance
Operating force
(reference characteristics)
Single pole
Double pole
at 6
×
10
3
ope. or less
from 6
×
10
3
ope. to 10
4
Mechanical
Electrical
Min. 5
×
10
4
(at 20 cpm.)
Min. 10
4
(at 7 cpm., at rated load)
Min. 100 MΩ
(at 500V DC measured by insulation resistive meter)
2,000 Vrms detection current: 10 mA
Max. 100mΩ
Max. 30°C (UL1054)
Max. 55°C (VDE0630)
10 to 55 Hz at double amplitude of 1.5mm
Min. 490m/s
2
{50 G}
40 N {4.08kgf} for 1 minute
(operating direction)
100 N {10.2kgf} for 1 minute or more
(Pull & push direction)
–25°C to +85°C
– 13
°
F to +185
°
F
(Not freezing below 0°C
32
°
F
)
Max. 85%R.H.
UL94V-0
Min. 175
2.45
±
1.47N {0.25
±0.15kgf}
4.5
±
2.5N {0.46
±0.25kgf}
Remark: Test conditions are in accordance with EN61058-1, UL1054 and JIS C 6571.
21
J8(AJ8)
DIMENSIONS
1) .250 Quick-connect terminal/Short guard type
Long guard type
.250 Quick-connect terminal
Double pole
15
.591
12.8
.504
10
.394
7.7
.303
ON
OFF
mm
inch
General tolerance
±0.5
±.020
Diagram of recommended
locations for panel
mounting holes
X
32 deg
7.7
.303
ON
OFF
−0
12.9
+0.1
−0
.508
+.004
±4
Single pole
30
1.181
30
1.181
32 deg
±4
2
.079
16
.630
4.4
.173
10.6 11
.417 .433
19.5
.768
2
.079
16
.630
4.4
.173
10.6
.417
Panel thickness
0.75 to 1.25
.030 to .049
1.25 to 2
.049 to .079
2 to 3
.079 to .118
X
28.2
+0
–0.1
1.110
+0
–.004
28.4
+0
–0.1
1.118
+0
–.004
28.8
+0
–0.1
1.134
+0
–.004
φ
1.75
φ
.069
15
.591
28
1.102
6.35
.250
φ
1.75
φ
.069
15
.591
28
1.102
6.35
.250
8.75
.344
12.5
.492
0.8
.031
4.375
.172
2) Soldering terminal
Long guard type
Soldering terminal
Double pole
15
.591
12.8
.504
10
.394
7.7
.303
ON
OFF
Single pole
30
1.181
32
±4
deg
7.7
.303
ON
OFF
Diagram of recommended
locations for panel
mounting holes
X
30
1.181
32
±4
deg
2
.079
16
.630
−0
12.9
+0.1
−0
.508
+.004
19.5
.768
2
.079
16
.630
2.5
.098
15
.591
28
1.102
4.375
.172
3.5
.138
10.6 11
.417 .433
Panel thickness
0.75 to 1.25
.030 to .049
1.25 to 2
.049 to .079
2 to 3
.079 to .118
X
28.2
+0
–0.1
1.110
+0
–.004
28.4
+0
–0.1
1.118
+0
–.004
28.8
+0
–0.1
1.134
+0
–.004
10.6
.417
2.5
.098
15
.591
28
1.102
3.5
.138
8.75
.344
12.5
.492
0.8
.031
3) PC board terminal
Double pole
15
.591
±.004
3
±0.2
.118
±.008
±0.1
PC board pattern
Single pole
1.2
±0.1
.047
±.004
8.75
±0.1
.344
±.004
15
.591
±.004
3
±0.2
.118
±.008
±0.1
Diagram of recommended locations for
panel mounting holes
X
1.2
±0.1
.047
±.004
4.375
±0.1
.172
±.004
−0
12.9
+0.1
−0
.508
+.004
Double pole
15
.591
12.8
.504
10
.394
7.7
.303
ON
OFF
Single pole
30
1.181
32
±4
deg
19.5
.768
2
.079
16
.630
(7.5)
(.295)
2
.079
15
.591
28
1.102
4
.157
8.75
.344
12.5
.492
0.8
.031
4.375
.172
Panel thickness
0.75 to 1.25
.030 to .049
1.25 to 2
.049 to .079
2 to 3
.079 to .118
X
28.2
+0
–0.1
1.110
+0
–.004
28.4
+0
–0.1
1.118
+0
–.004
28.8
+0
–0.1
1.134
+0
–.004
22
J8(AJ8)
4) PC board right angle terminal
PC board pattern
Double pole
15
±0.1
.591
±.004
3
±0.2
.118
±.008
1.2
±0.1
.047
±.004
8
±0.1
.315
±.004
mm
inch
General tolerance
±0.5
±.020
Diagram of recommended locations for
panel mounting holes
X
15
±0.1
.591
±.004
3
±0.2
.118
±.008
1.2
±0.1
.047
±.004
21.0
±0.3
.827
±.012
−0
12.9
+0.1
17.5
±0.3
−0
.508
+.004
.689
±.012
Single pole
Terminal side
4.375
.172
±.004
±0.1
Double pole
30
1.181
32°
±4
7.7
.303
ON
OFF
Single pole
15
.591
12.8
.504
10
.394
19.5
.768
2
.079
16
.630
Panel thickness
2
.079
X
28.2
+0
–0.1
1.110
+0
–.004
28.4
+0
–0.1
1.118
+0
–.004
28.8
+0
–0.1
1.134
+0
–.004
0.75 to 1.25
.030 to .049
1.25 to 2
.049 to .079
12.5
.492
8 0.8
.315 .031
28
1.102
4
.157
2 to 3
.079 to .118
Remark: Left angle terminals type is also available.
My method: The total length of the IP + 14 (Ethernet header length) = the length of the entire frame. However, most packets captured by IRIS can be calculated using my method, but sometimes it is not ...
General usage of blocking and non-blocking assignments:1 ) Using blocking assignment in the always block that describes the combinational logic will synthesize into a combinational logic circuit struc...
I need to use GPMC to expand a ferroelectric chip, so I need to set up GPMC. But I don't quite understand how to set the value of the GPMC_CONFIG7_i register. If anyone has experience in this area, pl...
I recently purchased some AD6654 chips and the evaluation board AD6654/PCBZ. During the debugging of this board, some problems occurred. ADI's technical support likes to play dead (it is recommended n...
1. Project Overview
1.1 Introduction
Currently, most music files are saved in MP3 format, a lossy audio compression format that cannot perfectly reproduce the original music. With the exp...[Details]
Some time ago, I attended the 4th Energy Chemistry Forum of the Chinese Chemical Society and learned about high-energy-density and high-safety batteries. I would like to summarize and share this wi...[Details]
Long ago, the lifespan of cars in my country was 15 years. Once a car reached 15 years old, it was forced to be scrapped. However, the policy was later changed. As long as the car does not exceed 6...[Details]
We are entering a new era where people are increasingly affordably equipped with more electronic gadgets. Electronics have become essential to our lives. For example, the average consumer now owns ...[Details]
When discussing autonomous driving technology, there are often two extremes: on the one hand, there's the vision of "fully autonomous driving," while on the other, there's concern about potential s...[Details]
With the increasing popularity of automated equipment, linear modules, a common auxiliary device for automated equipment, have also seen a bright future. In particular, in recent years, many small ...[Details]
Plug-in hybrid vehicles (PHEVs) utilize two powertrains. Their pure electric range is typically inferior to that of pure electric vehicles, often reaching less than half that. Currently, mainstream...[Details]
Lithium-ion batteries are a key component of electric vehicles. Their high energy density enables them to store a large amount of energy in a relatively compact and lightweight package, which is cr...[Details]
The drive shaft is a high-speed, low-support rotating body, so its dynamic balance is crucial. Generally, drive shafts undergo dynamic balancing tests and adjustments on a balancing machine before ...[Details]
Recently, I received a request to use OK1028A-C to output PWM square wave. However, I found that there was no relevant instructions on the OK1028 platform, so I started writing this article.
A...[Details]
On August 19, Huawei's Executive Director and Chairman of the Device BG, Richard Yu, shared a Weibo post about a conversation he had with a Zunjie S800 owner. The owner had driven over 5,000 kilome...[Details]
The transition to SDVs (software-defined vehicles) involves more than just replacing parts; rather, it involves the organic connection of various elements, from internal vehicle systems to ext...[Details]
This new standardized, pre-integrated computing platform is designed to accelerate chip development, reduce development costs, and provide scalable software to power the AI-defined car.
...[Details]
System Principle
According to the average imbalance rate of the branch three-phase phase line load and the average value of the branch phase line current, the adjustment of the phase line load...[Details]
The basic structure of the power grid dispatching automation system includes three parts: control center, master station system, plant terminal (RTU) and information channel. According to the diffe...[Details]