EEWORLDEEWORLDEEWORLD

Part Number

Search

PB-12311Z3B

Description
Standard Ordering Table . Pushbutton Switches . Panelmount Maintained and Momentary Action (SPDT)
File Size200KB,4 Pages
ManufacturerETC2
Download Datasheet View All

PB-12311Z3B Overview

Standard Ordering Table . Pushbutton Switches . Panelmount Maintained and Momentary Action (SPDT)

MINIATURE SWITCHES
Standard Ordering Table – Pushbutton Switches – Panelmount Maintained
and Momentary Action (SPDT)
HOW TO ORDER YOUR DESIGN
(Bold Face Type indicates items normally in Distributor Stock)
Following the table from left to right, the designer is able to specify
the options wanted. The options are described and illustrated on
pages 15-16.
Pushbutton
Switch Series
Circuit
Cap
Size
Cap
Color
To determine a part number select the options desired and fill in
the boxes in the selection guides illustrated below.
Pushbutton Switch Selection Guide
Terminal
Type
Contact
Material
Other
+
Base P/N
PB
Circuit
-123
ON-NONE-ON
Push to make
contact and Push
again to reverse
action
-126
ON-NONE-ON
*
Normally Open or
Normally Closed.
(For NC circuit
use Terminal 2 &
1, for NO. 2 & 3,
for NC and NO. 1,
2 & 3)
+
Cap Size
0
— No Cap
1
— .200 Dia.
2
— .310 Dia.
3
— 375 Dia.
+
+
+
+
Suffix Numbers & Letters — Add to Base Catalog Number
Cap Color
0
— No Cap
1
— Black
2
— White
3
— Red
Terminal Options
Z
— Solder Lugs
C
— Printed Circuit
Z3
— Quick Connect
W
— .750” Wirewrap
W1
— .964” Wirewrap
W3
— .425” Wirewrap
W4
— 1.0625” Wirewrap
A
— Right Angle P.C.
AV
— Vertical P.C.
.100 Spacing
AV2
— Vertical P.C.
.150 Spacing
Contact Material-Type
B
— Gold/Nickel/
Brass
G
— Gold/Nickel/
Silver
Q
— Coin Silver
K
L
M
Other Options
Epoxy Sealed
Terminals
PBS
Plunger Seal
PBW
Plunger & Panel
Seal
*
Momentary Contact
EXAMPLES:
PB-12331ZQ
Ratings are 0.4 VA-28 VAC or DC.
Epoxy seal standard on all terminal options.
Same as B, G and Q respectively except terminals brass with tin nickel alloy over
nickel plate. Consult factory for availability
= Maintained (Push-Push) circuit, .375” Black Cap, Solder Lug Terminals, Silver Contacts, 6 Amp Rating and Epoxy Sealed
Terminals
PBW-12613CB = Plunger & Panel Seal, Momentary circuit, .200” Red Cap epoxy sealed Printed Circuit Terminals and 50 Millionths Gold
over Brass contacts.
APPROXIMATE DIMENSIONS
PB
w /.375
CAP
MAINTAINED ACTION
PBS
w /.310
CAP
PBW
w /.200
CAP
MOMENTARY ACTION
SPECIFICATIONS
Contact Rating
– Letter codes G and Q – 6 amp at 125 VAC, 3 amp
at 250 VAC (
U.L. recognized, CSA certified
) or 6 amp at 28 VDC resistive.
Letter codes B and G – 0.5. volt-amp (VA) maximum @ 28 V
maximum (AC or DC).
Life Under Load (Resistive)
Alternate Action Suffix – 123; 100,000 make-and break cycles
Momentary Action Suffix – 126; 60,000 make-and-break cycles
Initial Contact Resistance
– 10 milliohms max. 3 VDC, 100 ma for
both silver and gold plated contacts.
Insulation Resistance
– 1,000 MBG.
Dielectric Strength
– 1,000 volts rms at sea level.
Bushing Strength
– 12 pound-inches without physical damage to
switch.
-126
-123
Operating Force
Pretravel
Overtravel
1.5 lb.
1.75 lb.
.043 Max. .106 Max.
.009 Min. .008 Min.
MATERIALS
Base (body)
— Diallyl Phthalate.
Bushing
— Brass, nickel plated.
Clamp (frame)
— Stainless steel.
Switching Contacts and Rockers
Letter Code B — gold/nickel/brass
Letter Code G — gold/nickel/silver
Letter Code Q — Coin silver
Center Terminal
Letter Codes B, G — Gold flash/nickel/brass
Letter Code Q — Silver plated brass.
Hardware
PB and PBS Series
(2) W-NU-11 hex nuts
(1) W-WA-16 internal tooth lockwasher
PBW Series
(1) W-NU-11 hex nut
(1) W-WA-16 internal tooth lockwasher
(1) W-WA-44 neoprene panel seal
Litho in U.S.A GG
14
DSP Control Problems of BLDC
Hello, teachers. I am currently working on the control of BLDC from open loop to speed closed loop. I am using TI's BLDC-sensored routine. When running in open loop, the circuit waveform of the motor ...
studyking Analog electronics
Understand low-pass, high-pass, band-pass, band-stop, and state-adjustable filters at once!
The second-order voltage-controlled low-pass filter circuit is shown in the figure. R1, C1 and R2, C2 respectively form two first-order low-pass filters, but C1 is connected to the output end to intro...
灞波儿奔 Analogue and Mixed Signal
Urgently hiring analog electronics engineers (electronic engineers) with an annual salary of 70,000-250,000
Our company is an internationally leading RD and production manufacturer of optoelectronic testing equipment with more than 500 employees. It is located in the beautiful Hangzhou, Zhejiang, and is als...
everfine123 Recruitment
Talk about the problem of using MSP430F5324 FLASH as EEPROM
[backcolor=white][b]The flash in the INFO area of MSP430F5324 is used as EEPROM. Sometimes the storage, reading and writing are OK. The program should be fine. However, the 128 bytes after 0x1980 cann...
Jacktang Microcontroller MCU
A high-precision current detection circuit that costs less than 1 cent;
Yesterday, I was resting and had a chat with a friend. My friend showed me this circuit he designed. Please analyze it and tell me what kind of circuit it is. He said it is the most accurate and the l...
czl618 Power technology
E-commerce turns to embedded development, seeking development
I participated in embedded training and transferred to this industry. Now I work in a company doing QT development. I want to develop at the bottom level and learn embedded system thoroughly. I would ...
beatlesm Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2539  1327  1237  1839  1656  52  27  25  38  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号