EEWORLDEEWORLDEEWORLD

Part Number

Search

PB-12300CB

Description
Standard Ordering Table . Pushbutton Switches . Panelmount Maintained and Momentary Action (SPDT)
File Size200KB,4 Pages
ManufacturerETC2
Download Datasheet View All

PB-12300CB Overview

Standard Ordering Table . Pushbutton Switches . Panelmount Maintained and Momentary Action (SPDT)

MINIATURE SWITCHES
Standard Ordering Table – Pushbutton Switches – Panelmount Maintained
and Momentary Action (SPDT)
HOW TO ORDER YOUR DESIGN
(Bold Face Type indicates items normally in Distributor Stock)
Following the table from left to right, the designer is able to specify
the options wanted. The options are described and illustrated on
pages 15-16.
Pushbutton
Switch Series
Circuit
Cap
Size
Cap
Color
To determine a part number select the options desired and fill in
the boxes in the selection guides illustrated below.
Pushbutton Switch Selection Guide
Terminal
Type
Contact
Material
Other
+
Base P/N
PB
Circuit
-123
ON-NONE-ON
Push to make
contact and Push
again to reverse
action
-126
ON-NONE-ON
*
Normally Open or
Normally Closed.
(For NC circuit
use Terminal 2 &
1, for NO. 2 & 3,
for NC and NO. 1,
2 & 3)
+
Cap Size
0
— No Cap
1
— .200 Dia.
2
— .310 Dia.
3
— 375 Dia.
+
+
+
+
Suffix Numbers & Letters — Add to Base Catalog Number
Cap Color
0
— No Cap
1
— Black
2
— White
3
— Red
Terminal Options
Z
— Solder Lugs
C
— Printed Circuit
Z3
— Quick Connect
W
— .750” Wirewrap
W1
— .964” Wirewrap
W3
— .425” Wirewrap
W4
— 1.0625” Wirewrap
A
— Right Angle P.C.
AV
— Vertical P.C.
.100 Spacing
AV2
— Vertical P.C.
.150 Spacing
Contact Material-Type
B
— Gold/Nickel/
Brass
G
— Gold/Nickel/
Silver
Q
— Coin Silver
K
L
M
Other Options
Epoxy Sealed
Terminals
PBS
Plunger Seal
PBW
Plunger & Panel
Seal
*
Momentary Contact
EXAMPLES:
PB-12331ZQ
Ratings are 0.4 VA-28 VAC or DC.
Epoxy seal standard on all terminal options.
Same as B, G and Q respectively except terminals brass with tin nickel alloy over
nickel plate. Consult factory for availability
= Maintained (Push-Push) circuit, .375” Black Cap, Solder Lug Terminals, Silver Contacts, 6 Amp Rating and Epoxy Sealed
Terminals
PBW-12613CB = Plunger & Panel Seal, Momentary circuit, .200” Red Cap epoxy sealed Printed Circuit Terminals and 50 Millionths Gold
over Brass contacts.
APPROXIMATE DIMENSIONS
PB
w /.375
CAP
MAINTAINED ACTION
PBS
w /.310
CAP
PBW
w /.200
CAP
MOMENTARY ACTION
SPECIFICATIONS
Contact Rating
– Letter codes G and Q – 6 amp at 125 VAC, 3 amp
at 250 VAC (
U.L. recognized, CSA certified
) or 6 amp at 28 VDC resistive.
Letter codes B and G – 0.5. volt-amp (VA) maximum @ 28 V
maximum (AC or DC).
Life Under Load (Resistive)
Alternate Action Suffix – 123; 100,000 make-and break cycles
Momentary Action Suffix – 126; 60,000 make-and-break cycles
Initial Contact Resistance
– 10 milliohms max. 3 VDC, 100 ma for
both silver and gold plated contacts.
Insulation Resistance
– 1,000 MBG.
Dielectric Strength
– 1,000 volts rms at sea level.
Bushing Strength
– 12 pound-inches without physical damage to
switch.
-126
-123
Operating Force
Pretravel
Overtravel
1.5 lb.
1.75 lb.
.043 Max. .106 Max.
.009 Min. .008 Min.
MATERIALS
Base (body)
— Diallyl Phthalate.
Bushing
— Brass, nickel plated.
Clamp (frame)
— Stainless steel.
Switching Contacts and Rockers
Letter Code B — gold/nickel/brass
Letter Code G — gold/nickel/silver
Letter Code Q — Coin silver
Center Terminal
Letter Codes B, G — Gold flash/nickel/brass
Letter Code Q — Silver plated brass.
Hardware
PB and PBS Series
(2) W-NU-11 hex nuts
(1) W-WA-16 internal tooth lockwasher
PBW Series
(1) W-NU-11 hex nut
(1) W-WA-16 internal tooth lockwasher
(1) W-WA-44 neoprene panel seal
Litho in U.S.A GG
14
HuaDa MCU Ucos FreeRtos RTThread real-time operating system
Regarding the HuaDa MCU Ucos FreeRtos RTThread real-time operating system, 32-bit core MCU, due to the increase in flash and RAM resources, in some applications, the traditional single-task system may...
Jacktang Domestic Chip Exchange
2410 hardware clock is several tens of minutes slower per day
I would like to ask the experts, my 2410 hardware clock is 30-60 minutes slow every day when it is powered on and on AC, and 1 second slow every day when it is powered off. Please help me analyze it, ...
luck2001 Embedded System
Does the msp430 launchpad i/o port have pull-up and pull-down resistors?
As the title says, please help. Or is there an external pull-up and pull-down resistor on the board? Isn't the PxREN in the user's guide used to configure the pull-up and pull-down resistors? But I sa...
fxk416532131 Microcontroller MCU
Tips for choosing a car audio amplifier
Whether you are a car audio enthusiast or not, you will be deeply attracted by the unique magnetism of these metallic equipment. But for most people, how to choose satisfactory audio equipment is a di...
小赛跑跑 Automotive Electronics
TC35 C Program
Help, can any hero give me a C program to test the communication between 51 microcontroller and TC35? Just input AT and it will return OK....
flyingaway Embedded System
f4xx series real time clock (REAL TIME CLOCK) sleep problem
Can the real-time clock of the 430 microcontroller still work properly when it is in low power mode? Can I use it to set a timed wake-up mode? Also, does the real-time clock need to be reset after pow...
860122 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 469  620  1186  2085  1167  10  13  24  42  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号