DC-DC Converter UNIT
PR Series
( 1 W REGULATED DC-DC CONVERTER )
FEATURES
1000VDC ISOLATION
EFFICIENCY UP TO 63%
INTERNAL SMD TECHNOLOGY
LOW COST
NO EXTERNAL COMPONENTS
REQUIRED
UP TO 1W REGULATED OUTPUT
POWER
SINGLE IN LINE PACKAGE
100% BURNED IN
MTBF > 1,800,000 HOURS
OUTPUT SPECIFICATIONS
Voltage Setpoint Accuracy
Temperature Coefficient
Ripple & Noise (20MHz
BW)
Line Regulation
1
Load Regulation
2
Short Circuit Protection
+/- 0.5% max
+/- 0.5% max
Current Limit
Protection
Short Circuit Restart
Automatic
+/- 2% max
+/- 0.03%/
O
C
100mVp-p max
INPUT SPECIFICATIONS
Input Voltage Range
Input Filter
+/- 10% max
Capacitor Type
GENERAL SPECIFICATIONS
Efficiency
50% min
Isolation Voltage
3
Isolation Resistance
Switching Frequency
Isolation Capacitance
MTBF
Weight
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
-25
O
C to +71
O
C
-55
O
C to +125
O
C
Free-Air Convection
1000 VDC min
9
10 ohms min
100 KHz min
80pF max
1,800,000 Hours
2.3g Typ
Non-Conductive Plastic
19.6mm*7.1mm*10.2mm
ALL SPECIFICATIONS TYPICAL AT NOMINAL
LINE,
FULL
LOAD
,
AND
25
O
Case Material
Case Size
C
UNLESS
OTHERWISE NOTED.
1
2
3
Line Regulation is for High Line to Low Line.
Load Regulation is for output load current change from 10% to 100%.
For 60 seconds
www.Power-Systems.de
Page: 1 / 4
Version: 4-Oct-02
DC-DC Converter UNIT
PR Series
( 1 W REGULATED DC-DC CONVERTER )
SELECTION GUIDE
1W OUTPUT
MODEL
NUMBER
INPUT
(VDC)
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
OUTPUT
(VDC)
5
12
15
5
12
15
5
12
15
OUTPUT
(mA)
200
84
67
200
84
67
200
84
67
INPUT
CURRENT(mA) EFF ISOLATION
FULL
LOAD
NO
LOAD
20
32
32
10
38
15
6
6
10
57
61
62
59
53
63
62
63
61
1000
1000
1000
1000
1000
1000
1000
1000
1000
OUTPUT
POWER
(Watt)
1
1
1
1
1
1
1
1
1
VOLTAGE VOLTAGE CURRENT
(%)
(VDC)
PRS-0505C
PRS-0512C
PRS-0515C
PRS-1205C
PRS-1212C
PRS-1215C
PRS-2405C
PRS-2412C
PRS-2415C
350
330
322
141
158
132
67
66
68
Note: Other input to output voltages may be available. Please contact factory.
www.Power-Systems.de
Page: 2 / 4
Version: 4-Oct-02
DC-DC Converter UNIT
PR Series
( 1 W REGULATED DC-DC CONVERTER )
TYPICAL PERFORMANCE CUREVES
DERATING CURVE
1.2
EFFICIENCY VS LOAD
EFFICIENCY(%)
70
100
OUTPUT POWER(W)
0.9
0.6
0.3
0.0
-25
0
25
50
80.0
60.0
40.0
20.0
0.0
0
20
40
60
80
100
SAFE
OPERATING
AREA
TA(degree C)
% OF RATED LOAD(%)
PR SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
No external capacitance is required for operation of the PR series.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 250KHz is required.
External output capacitance is not required for operation, however it is recommended that 10uF
tantalum and 0.1uF ceramic capacitance be selected for reduced system noise.
Additional output capacitance may be added for increased filtering, but should not exceed 100uF.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
74360 Ilsfeld-Auenstein ( Germany ) Dörnet 8
E-mail: Info@Power-Systems.de
Tel: + 49 / 70 62 / 67 59 – 6
Fax: + 49 / 70 62 / 67 59 -80
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 4 / 4
Version: 4-Oct-02