Notes: 1. PC board type and 1 coil latching type are manufactured by lot upon receipt of order.
2. Certified by UL, CSA and TÜV
ASCTB208E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
SP
TYPES
Contact arrangement
Nominal coil voltage
3V DC
5V DC
2 Form C
6V DC
12V DC
24V DC
48V DC
3V DC
5V DC
4 Form C
6V DC
12V DC
24V DC
48V DC
Single side stable
Part No.
SP2-DC3V
SP2-DC5V
SP2-DC6V
SP2-DC12V
SP2-DC24V
SP2-DC48V
SP4-DC3V
SP4-DC5V
SP4-DC6V
SP4-DC12V
SP4-DC24V
SP4-DC48V
2 coil latching
Part No.
SP2-L2-DC3V
SP2-L2-DC5V
SP2-L2-DC6V
SP2-L2-DC12V
SP2-L2-DC24V
SP2-L2-DC48V
SP4-L2-DC3V
SP4-L2-DC5V
SP4-L2-DC6V
SP4-L2-DC12V
SP4-L2-DC24V
SP4-L2-DC48V
Standard packing (2 Form C): Carton: 20 pcs.; Case: 200 pcs.
Standard packing (4 Form C): Carton: 10 pcs.; Case: 100 pcs.
Note: PC board type and 1 coil latching type are manufactured by lot upon receipt of order.
* For terminal sockets and mounting boards sockets, see page 152 and 153.
RATING
1. Coil data
1) Single side stable
Nominal coil
voltage
3V DC
5V DC
6V DC
12V DC
24V DC
48V DC
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
Pick-up voltage
(at 20°C
68°F)
Drop-out voltage
(at 20°C
68°F)
Nominal operating
current
[±10%] (at 20°C
68°F)
100mA
60.2mA
50mA
25mA
12.5mA
6.2mA
Coil resistance
[±10%] (at 20°C
68°F)
30Ω
83Ω
120Ω
480Ω
1,920Ω
7,700Ω
150%V of
nominal voltage
Nominal operating
power
Max. applied voltage
300mW
2) 2 coil latching
Nominal coil
voltage
3V DC
5V DC
6V DC
12V DC
24V DC
48V DC
70%V or less of
nominal voltage
(Initial)
70%V or less of
nominal voltage
(Initial)
Set voltage
(at 20°C
68°F)
Reset voltage
(at 20°C
68°F)
Nominal operating
current
[±10%] (at 20°C
68°F)
Set coil
100mA
60.2mA
50mA
25mA
12.5mA
6.2mA
Reset coil
100mA
60.2mA
50mA
25mA
12.5mA
6.2mA
Coil resistance
[±10%] (at 20°C
68°F)
Set coil
30Ω
83Ω
120Ω
480Ω
1,920Ω
7,680Ω
Reset coil
30Ω
83Ω
120Ω
480Ω
1,920Ω
7,680Ω
Nominal operating
power
Set coil
Reset coil
Max. applied voltage
300mW
300mW
150%V of
nominal voltage
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB208E 201202-T
SP
2. Specifications
Characteristics
Initial contact pressure
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Rating
Max. switching voltage
Max. switching current
Minimum operating power
Nominal operating power
Min. switching capacity (Reference value)*
1
Insulation resistance (Initial)
(25°C, 50% relative humidity)
Breakdown voltage
(Initial)
Electrical
characteristics
Between open contacts
Between contact and coil
Between contact sets
Operate time [Set time] (at 20°C
68°F)
Release time [Reset time] (at 20°C
68°F)
Temperature rise (coil) (at 20°C
68°F)
Shock resistance
Mechanical
characteristics
Vibration resistance
Mechanical
Expected life
Electrical (resistive load)
Functional
Destructive
Functional
Destructive
Item
Specifications
2 Form C: Approx. 0.392 N (40 g
1.41 oz),
4 Form C: Approx. 0.196 N (20 g
0.71 oz)
2 Form C, 4 Form C
Max. 30 mΩ (By voltage drop 6 V DC 1A)
Stationary contact: Au flashed AgSnO
2
type, Movable contact: AgSnO
2
type
2 Form C: 15 A 250 V AC, 4 Form C: 10 A 250 V AC
2 Form C: 3,750 VA, 300 W, 4 Form C: 2,500 VA, 300 W
2 Form C, 4 Form C: 250 V AC, 30 V DC (48V DC: Max. 2A)
2 Form C: 15 A (AC) 10 A (DC), 4 Form C: 10 A
150mW (Single side stable, 2 coil latching)
300mW (Single side stable, 2 coil latching)
100 mA 5V DC
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Breakdown voltage” section.
1,500 Vrms for 1 min. (Detection current: 10 mA)
3,000 Vrms for 1 min. (Detection current: 10 mA)
3,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 30 ms [Max. 30 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 20 ms [Max. 30 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Max. 40°C
(By resistive method, nominal voltage applied to the coil; nominal switching capacity.)
Min. 392 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 3 mm
Min. 5×10
7
(at 180 times/min.)
2 Form C:
Min. 10
5
(15 A 250 V AC [at 20 times/min.]), Min. 10
5
(10 A 30 V DC [at 20 times/min.])
4 Form C:
Min. 10
5
(15 A 250 V AC [at 20 times/min.]), Min. 10
5
(10 A 30 V DC [at 20 times/min.])
Ambient temperature: –50°C to +60°C
–58°F to +140°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at rated load)
2 Form C: 50 g
1.76 oz;
4 Form C: 65 g
2.29 oz
Contact
Conditions
Unit weight
Conditions for operation, transport and storage*
2
Max. operating speed
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Operate and release time (Single side stable)
SP2
50
Coil temperature rise
SP4
50
Tested sample: SP2-DC24V
Ambient temperature: 20 to 22°C
68 to 72°F
50
Operate/release time, ms
Operate/release time, ms
Temperature rise,
°C
40
40
Operate time
30
40
15 A
10 A
5A
30
Operate time
30
20
Release time
10
Max.
Min.
Max.
Min.
20
Release time
10
Max.
Min.
Max.
Min.
20
0A
10
0
80
100
Coil applied voltage,%V
90
110
0
80
100
Coil applied voltage,%V
90
110
0
19.2 21.6 24.0 26.4 28.8 31.2 33.6 36.0
Coil applied voltage,%V
ASCTB208E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
SP
Tested sample: SP4-DC24V
Ambient temperature: 27 to 29°C
81 to 84°F
50
Pick-up/drop-out voltage, V
N.C.
N.O.
15
Pick-up voltage
Max.
x
Min.
Contact resistance, mΩ
15
Electrical life
(SP2, 15 A 250 V AC resistive load)
Temperature rise,
°C
40
10 A
30
5A
20
0A
Max.
10
10
x
Max.
x
Min.
Min.
5
Drop-out voltage
Max.
x
Min.
1
2
3
4
5
6
7
8
9
10
5
10
0
19.2 21.6 24.0 26.4 28.8 31.2 33.6 36.0
Coil applied voltage,%V
0
0
1
2
3
4
5
6
7
8
9
10
No. of operations,
×10
4
No. of operations,
×10
4
Electrical life
(SP4, 10 A 250 V AC resistive load)
Pick-up/drop-out voltage, V
N.C.
N.O.
Contact resistance, mΩ
15
Pick-up voltage
50
40
30
20
10
0
x
Min.
1
2
3
4
5
6
7
8
9
10
Max.
Max.
x
Min.
10
5
Drop-out voltage
Max.
x
Min.
1
2
3 4 5 6 7 8 9
No. of operations,
×10
4
10
0
No. of operations,
×10
4
DIMENSIONS
(mm
inch)
2 Form C
Plug-in terminal
CAD Data
External dimensions
1
.039
50
1.969
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
PC board type
CAD Data
External dimensions
0.5
.020
20.5
.807
1.5
.059
2
.079
0.5
.020
5.5
.217
Schematic (Bottom view)
Single side stable
1
5
6
7
10
.394
25.6
1.008
15.24
.600
2
8
9
10
10.16 10.16 10.16 10.16
.400 .400 .400 .400
15.24
.600
(Deenergized condition)
General tolerance:
±0.3
±.012
20.5
.807
1.5
.059
7.15
.281
10.16 10.16 10.16 10.16
.400 .400 .400 .400
4.75
.187
FASTON #187
15.24
.600
2 coil latching
1
5
SET
2
8
9
6
7
RST
10
4
3
PC board pattern (Bottom view)
10-2.5 dia.
10-.098 dia.
(Reset condition)
General tolerance:
±0.3
±.012
10.16 10.16 10.16 10.16
.400 .400 .400 .400
Tolerance:
±0.1
±.004
Diagram shows the “reset” position when terminals 3 and 4 are energized. Energize terminals 1 and 2 to transfer contacts.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB208E 201202-T
SP
4 Form C
Plug-in terminal
CAD Data
External dimensions
1
.039
50
1.969
0.5
.020
7.62
.300
10
.394
36.8
1.449
15.24
.600
7.62
.300
2
.079
PC board type
CAD Data
External dimensions
20.5
.807
1.5
.059
0.5
.020
5.5
.217
7.62
.300
Schematic (Bottom view)
Single side stable
11
12
13
1
5
6
7
10.16 10.16 10.16 10.16
.400 .400 .400 .400
15.24
.600
7.62
.300
2
8
9
10
General tolerance:
±0.3
±.012
20.5
.807
1.5
.059
7.15
.281
10.16 10.16 10.16 10.16
.400 .400 .400 .400
4.75
.187
14
15
16
(Deenergized condition)
PC board pattern (Bottom view)
16-2.5 dia.
16-.098 dia.
7.62
.300
15.24
.600
7.62
.300
10.16 10.16 10.16 10.16
.400 .400 .400 .400
2 coil latching
11
12
13
1
5
SET
6
7
RST
3
2
8
9
10
4
General tolerance:
±0.3
±.012
14
15
16
(Reset condition)
Tolerance:
±0.1
±.004
Diagram shows the “reset” position when terminals 3 and 4 are energized. Energize terminals 1 and 2 to transfer contacts.
This porting example is for the LM3S9B92-EVM development board. The code can be slightly modified to suit other series of Stellaris ARM. For detailed code description, please refer to the "LM3S9B92-EV...
I installed CADENCE VIRTUSO but I can't open it. I used it before and even drew circuits. Now I don't know why it can't be used. Please help me~~[/size] [size=12pt]The problem is as attached[/size] [s...
I bought this book, it's very good, I recommend it to everyone.Screenshot on DoubanThe book explains a lot of theoretical things, involving things related to communications, and is quite classic....
I wanted to learn this subject, but then I found that I knew too little. There is no way, I have to go through this period. Let me share it with you so that we can make progress together!...
How can I set the chip coin set in the previous data download to 0, or remove it? I just set it randomly at the beginning, and now I want to remove it! I suggest the forum to cancel the chip coin down...
Today's computer peripherals are pursuing high speed and high versatility. In order to meet user needs, seven companies led by Intel launched the USB (Universal Serial Bus) bus protocol in 1994, wh...[Details]
The solidification and modularization of intelligent video analysis algorithms are the current trends in the application of intelligent video analysis technology. It perfectly combines intelligent ...[Details]
A multi-point temperature control heating control system was designed using the SST89E564RC single-chip microcomputer and a new temperature measuring device. The heating system can be controlled in...[Details]
my country is a big country in agriculture, grain production and consumption. Grains are a necessary condition for our nation to survive and develop. The flour processing industry will exist forever w...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]
This paper designs a 16x16LED Chinese character display bar based on single-chip dynamic scanning control, briefly analyzes the principle of Chinese character display, and studies how the LED displ...[Details]
In 2012, more than half of the cars in the European, Japanese and American car markets will be equipped with color displays, navigation systems, satellite communications and other in-vehicle infota...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guangzho...[Details]
Introduction
In industrial control, speed measurement is often required. Generally, a contact tachometer is used. This tachometer must be placed against the center of the shaft to measure. It...[Details]
Nowadays, more and more people have digital cameras. The convenience and speed of digital cameras have gradually replaced film cameras and become the main tool for people's daily photography. The n...[Details]
1 Battery technology determines the fate of energy vehicles
Regardless of whether new energy vehicles are hybrid or pure electric vehicles, they cannot do without the core technology of batter...[Details]
The rapid development of the automobile industry has promoted the progress of global machinery, energy and other industries, as well as the development of economy, transportation and other aspects,...[Details]
Li/SOCl2 batteries (lithium sub-cells) have the advantages of high operating voltage, stable discharge voltage, wide operating temperature range and long storage life, and have been widely used in ...[Details]
Any power transmission and distribution equipment and power-consuming devices cannot be pure resistive loads, so they must occupy a certain amount of reactive power. The existence of reactive curre...[Details]
At present, single-chip microcomputers have been widely used in home appliances, medical treatment, instrumentation, industrial automation, aerospace and other fields. The more popular types of sin...[Details]