EEWORLDEEWORLDEEWORLD

Part Number

Search

2649LH/3C21101L110V1/3

Description
Rocker Switch, DPDT, Latched, 10A, 12VDC, Quick Connect Terminal, Plain Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size230KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2649LH/3C21101L110V1/3 Overview

Rocker Switch, DPDT, Latched, 10A, 12VDC, Quick Connect Terminal, Plain Rocker Actuator, Panel Mount

2649LH/3C21101L110V1/3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typePLAIN ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationBLUE LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
method of packingBULK
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typeROCKER SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
Models for peak currents
• Insulation resistance : 1.000 MΩ min. at 500VDC
Models 2600SLH with silver cadmium oxide contacts
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
are discontinued. They will be replaced by switches
3.000 Vrms 50 Hz min. between terminals and metal panel
with silver tin oxide contacts.
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
Power-related issues
There are two types of phase-locked links: 1. By changing the carrier period 2. By changing the sine table lookup pointer...
gaoxiao Microcontroller MCU
Can ADS1.2 perform software simulation?
I wonder if ADS1.2 can perform software simulation? If so, how to set it up?...
SAM1978 Embedded System
If the human body is powered by electricity, how much electricity does a normal person consume in a day?
If the human body is powered by electricity, how much electricity does a normal person consume in a day?...
ohahaha Analogue and Mixed Signal
STM32 -M3 core CPU 32-bit CPU timer problem
Why is the practical bit number of the timer of the STM32-M3 core 32-bit CPU only 16 bits? What do you think?...
anvy178 stm32/stm8
Studying the road to electric motor driving-3: The size of "torque"
[i=s]This post was last edited by MianQi on 2021-6-15 13:56[/i]Studying the road to electric motor driving-3: The size of "torque"...
MianQi Motor Drive Control(Motor Control)
Siemens mm440, a question that has troubled me for a long time
I have a question: I recently repaired a 3kW Siemens mm440 inverter, and the module exploded. After removing it, the driver board was repaired. The module was not installed first. A 540V DC voltage wa...
eeleader-mcu Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 497  329  2008  1271  2604  11  7  41  26  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号