MIL–PRF (CWR Style) Established Reliability – T419 Series CWR19 Style MIL–PRF–55365/11
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
VDC
Rated
Cap
µF
3.3
4.7
6.8
10
15
22
22
33
33
47
68
100
150
220
330
3.3
4.7
6.8
10
15
15
15
22
22
33
47
68
68
100
150
220
330
2.2
3.3
4.7
4.7
6.8
6.8
6.8
10
10
10
10
15
15
22
33
47
47
µF
Case Code/
Case Size
KEMET/EIA
A/1005
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
D/1510
E/2010
E/2010
E/2010
F/2214
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
G/2711
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
C/2005
B/1505
C/2005
D/1510
B/1505
C/2005
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T419A335(1)004(2)(3)(4)
T419A475(1)004(2)(3)(4)
T419A685(1)004(2)(3)(4)
T419B106(1)004(2)(3)(4)
T419B156(1)004(2)(3)(4)
T419B226(1)004(2)(3)(4)
T419D226(1)004(2)(3)(4)
T419D336(1)004(2)(3)(4)
T419E336(1)004(2)(3)(4)
T419E476(1)004(2)(3)(4)
T419E686(1)004(2)(3)(4)
T419F107(1)004(2)(3)(4)
T419G157(1)004(2)(3)(4)
T419H227(1)004(2)(3)(4)
T419H337(1)004(2)(3)(4)
T419A335(1)006(2)(3)(4)
T419A475(1)006(2)(3)(4)
T419B685(1)006(2)(3)(4)
T419B106(1)006(2)(3)(4)
T419B156(1)006(2)(3)(4)
T419D156(1)006(2)(3)(4)
T419E156(1)006(2)(3)(4)
T419D226(1)006(2)(3)(4)
T419E226(1)006(2)(3)(4)
T419E336(1)006(2)(3)(4)
T419F476(1)006(2)(3)(4)
T419F686(1)006(2)(3)(4)
T419G686(1)006(2)(3)(4)
T419G107(1)006(2)(3)(4)
T419G157(1)006(2)(3)(4)
T419H227(1)006(2)(3)(4)
T419H337(1)006(2)(3)(4)
T419A225(1)010(2)(3)(4)
T419A335(1)010(2)(3)(4)
T419B475(1)010(2)(3)(4)
T419C475(1)010(2)(3)(4)
T419B685(1)010(2)(3)(4)
T419C685(1)010(2)(3)(4)
T419D685(1)010(2)(3)(4)
T419B106(1)010(2)(3)(4)
T419C106(1)010(2)(3)(4)
T419D106(1)010(2)(3)(4)
T419E106(1)010(2)(3)(4)
T419D156(1)010(2)(3)(4)
T419E156(1)010(2)(3)(4)
T419E226(1)010(2)(3)(4)
T419F336(1)010(2)(3)(4)
T419F476(1)010(2)(3)(4)
T419G476(1)010(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/11
Part Number
(See below for
part options)
CWR19C(3)335(1)(2)A(5)
CWR19C(3)475(1)(2)A(5)
CWR19C(3)685(1)(2)A(5)
CWR19C(3)106(1)(2)B(5)
CWR19C(3)156(1)(2)B(5)
CWR19C(3)226(1)(2)B(5)
CWR19C(3)226(1)(2)D(5)
CWR19C(3)336(1)(2)D(5)
CWR19C(3)336(1)(2)E(5)
CWR19C(3)476(1)(2)E(5)
CWR19C(3)686(1)(2)E(5)
CWR19C(3)107(1)(2)F(5)
CWR19C(3)157(1)(2)G(5)
CWR19C(3)227(1)(2)H(5)
CWR19C(3)337(1)(2)H(5)
CWR19D(3)335(1)(2)A(5)
CWR19D(3)475(1)(2)A(5)
CWR19D(3)685(1)(2)B(5)
CWR19D(3)106(1)(2)B(5)
CWR19D(3)156(1)(2)B(5)
CWR19D(3)156(1)(2)D(5)
CWR19D(3)156(1)(2)E(5)
CWR19D(3)226(1)(2)D(5)
CWR19D(3)226(1)(2)E(5)
CWR19D(3)336(1)(2)E(5)
CWR19D(3)476(1)(2)F(5)
CWR19D(3)686(1)(2)F(5)
CWR19D(3)686(1)(2)G(5)
CWR19D(3)107(1)(2)G(5)
CWR19D(3)157(1)(2)G(5)
CWR19D(3)227(1)(2)H(5)
CWR19D(3)337(1)(2)H(5)
CWR19F(3)225(1)(2)A(5)
CWR19F(3)335(1)(2)A(5)
CWR19F(3)475(1)(2)B(5)
CWR19F(3)475(1)(2)C(5)
CWR19F(3)685(1)(2)B(5)
CWR19F(3)685(1)(2)C(5)
CWR19F(3)685(1)(2)D(5)
CWR19F(3)106(1)(2)B(5)
CWR19F(3)106(1)(2)C(5)
CWR19F(3)106(1)(2)D(5)
CWR19F(3)106(1)(2)E(5)
CWR19F(3)156(1)(2)D(5)
CWR19F(3)156(1)(2)E(5)
CWR19F(3)226(1)(2)E(5)
CWR19F(3)336(1)(2)F(5)
CWR19F(3)476(1)(2)F(5)
CWR19F(3)476(1)(2)G(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Max/5 Min
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
3.0
4.0
6.0
8.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.8
4.0
4.0
6.0
10.0
10.0
20.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
3.0
3.0
4.0
4.0
µA @ +20ºC
Max/5 Min
DF
% @ 20ºC
120 Hz Max
6.0
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
6.0
8.0
6.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
% @ 20ºC
120 Hz Max
ESR
Ω @ +20ºC
100 kHz Max
12.0
12.0
12.0
8.0
8.0
8.0
4.0
4.0
3.0
3.0
3.0
2.0
1.0
1.0
0.9
12.0
12.0
8.0
8.0
8.0
5.0
3.0
5.0
3.5
3.5
3.5
1.5
1.0
1.1
1.1
0.9
0.9
12.0
12.0
8.0
5.5
8.0
5.5
5.0
8.0
5.5
4.0
3.5
5.0
3.0
2.0
1.5
1.5
1.0
Ω @ +20ºC
100 kHz Max
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated Cap
Case Code/
Case Size
KEMET Part Number
MIL–PRF–55365/11
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, C = -55°C +85°C before Weibull or Z = None. Designates Surge
current option.
Refer to Ordering Information for additional detail.
The CPU used is Samsung 2450. Under Wince5.0, I changed the horizontal screen to vertical screen. According to the method under 2440, I set the registry key to HKEY_LOCAL_MACHINE\System\GDI\Rotation] ...
1. Several nouns
ABI:
The specifications that an executable file must follow in order to run in a specific execution environment;
Separately generated relocatabl...[Details]
In recent years, with the increasing demand for manufacturing and automated production management, industrial barcode scanners have gradually become an indispensable part of the industrial manufact...[Details]
Wave soldering is a crucial electronic component soldering technique used in the production of a wide range of electronic devices, from home appliances to computers to avionics. The process is wide...[Details]
introduction
Bluetooth technology is a short-range wireless communication technology designed to replace wired cables. It is a wireless communication technology standard developed by the SIG, ...[Details]
Whether it is an electric car or an ordinary fuel car, for the vast majority of car buyers, the final cost of use is what they care about most. For fuel cars, how to save fuel is what drivers care ...[Details]
On August 22, Lantu Motors officially launched its Lanhai Intelligent Hybrid technology via an online livestream. This intelligent hybrid technology, which integrates a full-range 800V high-voltage...[Details]
Recently, South Korean robotics giant WIRobotics launched its first general-purpose humanoid robot, ALLEX, at the Robotics Innovation Center (RIH) at the Korea University of Science and Technology....[Details]
For autonomous vehicles to safely navigate the road, they must identify far more complex objects than just traffic lights, pedestrians, and other familiar objects. Among these obstacles is a crucia...[Details]
There are basically three causes of spontaneous combustion of electric vehicles: The first is that the battery components are punctured or suffer fatal damage due to a collision accident, and part ...[Details]
According to Nikkei, a survey found that global electric vehicle battery supply is expected to reach more than three times the required quantity due to
cooling
demand for electric vehicles,...[Details]
Tiantai Robot's official Weibo account announced on the evening of August 20 that Tiantai Robot Co., Ltd., together with strategic partners including Shandong Future Robot Technology Co., Ltd., Sha...[Details]
To improve the lateral active safety of intelligent connected vehicles, the identification and definition of unexpected functional safety scenarios for the EPS (Electronic Steering System) ...[Details]
Over the past decade, the narrative surrounding fuel vehicles has been one of decline and replacement. Under the onslaught of new energy vehicles, traditional automakers have been forced to acceler...[Details]
Inverter power supplies on the market can generally be divided into two categories: sine wave inverters and square wave inverters. Some engineers also like to categorize pure sine wave inverters as...[Details]
For today's new energy vehicles, they have different configurations from fuel vehicles, and some configurations have also become a selling point for manufacturers. Compared with traditional vehicle...[Details]