EEWORLDEEWORLDEEWORLD

Part Number

Search

LXA35VB47M

Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 35V, 20% +Tol, 20% -Tol, 47uF, Through Hole Mount, RADIAL LEADED
CategoryPassive components    capacitor   
File Size53KB,2 Pages
ManufacturerNIPPON CHEMI-CON
Websitehttp://www.chemi-con.co.jp
Download Datasheet Parametric View All

LXA35VB47M Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 35V, 20% +Tol, 20% -Tol, 47uF, Through Hole Mount, RADIAL LEADED

LXA35VB47M Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
capacitance47 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
dielectric materialsALUMINUM (WET)
leakage current0.01645 mA
Manufacturer's serial numberLXA
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-55 °C
Package shapeCYLINDRICAL PACKAGE
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)35 V
ripple current140 mA
surface mountNO
Delta tangent0.18
Terminal shapeWIRE
MINIATURE ALUMINUM ELECTROLYTIC CAPACITORS
High reliability, Long life, 105C
@Endurance
: 105C 5000 to 7000 hours
@Solvent-proof
type (see PRECAUTIONS AND GUIDELINES)
?SPECIFICATIONS
Items
Category
Temperature Range
Rated Voltage Range
Capacitance Tolerance
Leakage Current
Dissipation Factor
(tane)
Endurance
-55 to +105C
10 to 63V
dc
P20%
(M)
(at 20C, 120Hz)
I=0.01CV or 3MA, whichever is greater.
Where, I : Max. leakage current (MA), C : Nominal capacitance (MF), V : Rated voltage (V)
(at 20C after 2 minutes)
10V 16V 25V 35V 50V 63V
Rated Voltage (V
dc
)
0.30 0.25 0.22 0.18 0.15 0.12
tanE (Max.)
When nominal capacitance exceeds 1000MF, add 0.02 to the value above for each 1000MF increase.
(at 20C, 120Hz)
The following specifications shall be satisfied when the capacitors are restored to 20C after the rated voltage is applied for the specified
period of time at 105C.
Time
F6.3
to 10 : 5000 hours
F12.5
to 18 : 7000 hours
Capacitance change
[P30%
of the initial value
D.F. (tanE)
[300%
of the initial specified value
Leakage current
[The
initial specified value
The following specifications shall be satisfied when the capacitors are restored to 20C after exposing them for 1000 hours at 105C
without voltage applied.
Capacitance change
[P15%
of the initial value
D.F. (tanE)
[150%
of the initial specified value
Leakage current
[The
initial specified value
Characteristics
Shelf Life
?DIMENSIONS
(Radial Lead Type=VB) [mm]
FP0.5
FP0.5
Fd
Sleeve
fD
fd
F
fD'
L'
FD'
6.3
0.5
2.5
8
0.6
3.5
10 12.5 16
0.6 0.6 0.8
5.0 5.0 7.5
FD+0.5max.
L+1.5max.
18
0.8
7.5
L'
Vent
(except
F6.3)
15min.
4min.
(F6.3 to
F10)
(F12.5 to
F18)
Gas escape end seal
?PART
NUMBERING SYSTEM
LXA
50
VB
2R2
M
Cap tolerance (P20%)
Nominal cap code
Radial lead type
Rated voltage in volts
Series name
Capacitance
0.47MF
1.0MF
4.7MF
10MF
100MF
Code
R47
1
4R7
10
100
(1/2)
CAT. No. E1001C
The program written in EVC can run in CE5.0, but cannot run when copied directly to CE6.0. What should I do? ?
What should I do if the program written in EVC can run in CE5.0, but cannot run when copied directly to CE6.0? CE5.0 and CE6.0 are based on the same hardware platform. Some mfc dll files have been add...
lixiebin2003 Embedded System
A question about notes
struct _TEST { unsigned long var1; unsigned char var2; unsigned int var3:1; unsigned int var4:1; unsigned int var5:1; unsigned int var6:1; } Question: How much memory does this structure occupy on a 3...
vanlin1012 Embedded System
Microcontroller C Language Tutorial (Part 3)
Today we are talking about the fourth lesson that needs to be downloaded....
rain MCU
, I found that this book has many errors
I have read more than a dozen examples for a few days, but most of them have errors in the code. They are not correct when I write them down on the board. For example, I found that there are six error...
石玉 Microcontroller MCU
Help: After the computer was infected, ghost was performed, and the partition was changed. When repairing the partition, there was a sudden power outage and the desktop could not be displayed. Now the desktop shows invalid partition table.
After the computer was infected, ghost was performed and the partition was changed. When repairing the partition, there was a sudden power outage and the desktop could not be displayed. Now invalid pa...
zuigui111 Embedded System
GTM900 TCP connection data packet loss?
GTM900 TCP packet loss problem.. When GTM900 sends data using IPSEND in TCP, it sends 10 data but only receives 6 data. The delay time is 1S. I don't know why?...
ibmibm Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 187  915  92  2523  1802  4  19  2  51  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号