EEWORLDEEWORLDEEWORLD

Part Number

Search

TCL450DA3-DCP

Description
TIME DELAY BLOW ELECTRIC FUSE, 100A, 125VDC, INLINE/HOLDER
CategoryCircuit protection   
File Size107KB,2 Pages
ManufacturerETC1
Download Datasheet View All

TCL450DA3-DCP Overview

TIME DELAY BLOW ELECTRIC FUSE, 100A, 125VDC, INLINE/HOLDER

TYPE:
CATALOG NO.:
General Description
The CCL/TCL Series provides functional emer-
gency lighting in a variety of wattages up to 450
watts. High performance electronics and rugged
18 gauge steel construction ensure long-term life
safety reliability.
CCL/TCL Series
Housing
High Capacity Steel Emergency Lighting Units
6 and 12 Volt, 75 to 450 Watts
Wet Cell Lead Calcium Battery
Constructed of 18 gauge steel with a tan epoxy powder
coat finish.
Knockouts provided for mounting up to three lamp
heads.
Bi-color LED charge monitor/indicator and a “press-to
test” switch are located on the front of the cabinet.
Choice of wedge base, sealed beam tungsten, or halogen
lamp heads
Illumination
Illumination is accomplished with up to three
lamp heads mounted on the top of the unit. The
most popular lamp head for use with the CCL/TCL
Series is the “D” Series round sealed beam Par 36
tungsten lamp head. The “D” head is available up
to 30 watts.
Dimensions
CCL75, CCL100, CCL150, CCL225,
TCL150, TCL200
6.0”
(15.2 cm)
Electronics
120/277 VAC dual voltage input with surge-protected,
solid-state circuitry provides for a reliable charging
system.
Charging system is complete with low voltage
disconnect, AC lockout, brownout protection,
AC indicator lamp and test switch.
Includes two fused output circuits.
7.6”
(19.3 cm)
Shown: CCL150DL2
Battery
Low maintenance, free electrolyte, wet cell, lead
calcium battery
Specific gravity disk indicators show relative state
charge at a glance
Operating temperature range of battery is 65°F
(19°C)
to 85°F
(30°C)
12.0”
(30.5 cm)
16.0”
(40.6 cm)
TCL300, TCL450
6.0”
(15.2 cm)
12.0”
(30.5 cm)
Utilizes a fully automatic voltage regulated two-rate cur- Battery supplies 90 minutes of emergency power
rent limited solid-state charger -- initially provides a high
rate charge upon restoration of AC power, and provides
Code Compliance
trickle charge to maintain batteries at full capacity once UL 924 listed
float voltage is attained.
NFPA 101
Optional ACCU-TEST Self Diagnostics includes an auto-
NEC BOCA and OSHA illumination standard
matic 3 minute discharge test every 30 days. A manual
test is available from 1 to 90 minutes.
Performance
Warranty
27.0”
(12.7 cm)
Three year full electronics warranty
7.6”
(19.3 cm)
Input power requirements
120 VAC - 0.66 amps, 80 watts
277 VAC - 0.30 amps, 80 watts
One year full plus four year prorated battery warranty
Ordering Information
CCL
SERIES
CCL = 6 Volt
TCL = 12 Volt
150
DC
WATTAGE
6 Volt
75 = 75 Watts
100 = 100 Watts
150 = 150 Watts
225 = 225 Watts
12 Volt
(Includes standard voltmeter)
150 = 150 Watt
200 = 200 Watt
300 = 300 Watt
450 = 450 Watt
DL
LAMP
HEADS
6 Volt
DY = 8 Watt, Tungsten
DA = 18 Watt, Tungsten
DL = 25 Watt, Tungsten
DC = 30 Watt, Tungsten
12 Volt
DNY = 12 Watt, Tungsten
DE = 28 Watt, Tungsten
DK = 25 Watt, Tungsten
DG = 30 Watt, Tungsten
(Suggested lamp heads listed
above. Refer to the Accessories Section for
additional lamp head choices.)
2
# OF
HEADS
3 = Three
2 = Two
1 = One
TD1
FACTORY INSTALLED
OPTIONS
1
ACCESSORIES
A = Ammeter
2
ACF1 = 120 VAC Fuse
LMSHELF = Mounting Shelf 300-450W
ACF2 = 277 VAC Fuse
MXSHELF = Mounting Shelf 72-200W
ACP1 = 120 VAC Power Switch
ACP2 = 277 VAC Power Switch
AD = ACCU-TEST Self-Diagnostics
ADAL = ACCU-TEST with Alarm
ADTD = ACCU-TEST with Time Delay
3
DCP = DC Power Switch
EX = Special Input Transformer
(Specify voltage and frequency)
TD1 = 120 VAC Time Delay
3
TTD2 = 277 VAC Time Delay
3
V = Voltmeter
2
W = White Housing
Notes:
1) Some option combinations may impact UL list-
ing. consult factory for specifics.
2) Not available witj AD, ADAL, or ADTD options.
3) 15 minute delay.
C1063
R4
9/02 IH
People say it takes 5 years to get into simulation?
What do you think? Personally, I don’t think 5 years is long....
幸福的娃 Analog electronics
CAN communication problem of Fujitsu MB9BF506R
Has anyone used MB9BF506R for CAN communication? I would like to ask if there are too many reception errors, will the CAN bus be in a closed state? At this time, how do I start receiving again?...
liqiu880905 DIY/Open Source Hardware
Which register should be used to set the interrupt source that allows the system to wake up?
Why can some of my external interrupts wake up the system, but others can't? I also want to ask if there is a special register that can be set to allow only certain external interrupts to wake up the ...
白开水 Embedded System
fujitsu MB95F564KPMC
Structure diagramFeatures SummaryProduct Name MB95560K SeriesEncapsulation SOP-20/TSSOP-20/QFN32F2MC-8FX CPU Core Controller Optimization Instruction SetMultiplication and division instructions 16-bit...
bolin2009 ARM Technology
ARM-STM32 Campus Innovation Competition Help
ARM-STM32 Campus Innovation Competition winning works, who can send me a link, I have been looking for it all afternoon and can't find it...
flywith stm32/stm8
MFC program on PC + STM32 communication
I want to write an MFC program on PC to communicate with STM32 microcontroller. Many people on the Internet say that USB is used. Can I write it directly with the serial port? I checked and found some...
geyang1111 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1622  1396  120  2393  2370  33  29  3  49  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号