EEWORLDEEWORLDEEWORLD

Part Number

Search

2631LH/2A21608L24V/6

Description
Rocker Switch, SPST, Latched, 15A, 12VDC, Solder/quick Connect Terminal, Plain Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size229KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2631LH/2A21608L24V/6 Overview

Rocker Switch, SPST, Latched, 15A, 12VDC, Solder/quick Connect Terminal, Plain Rocker Actuator, Panel Mount

2631LH/2A21608L24V/6 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typePLAIN ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)15 A
Contact (DC) maximum rated R load15A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature125 °C
Minimum operating temperature-20 °C
method of packingBULK
sealDUST PROOF; WATER PROOF
surface mountNO
Switch actionLATCHED
switch functionSPST
Switch typeROCKER SWITCH
Termination typeSOLDER/QUICK CONNECT
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
Show the process of WEBENCH design + converting car battery to 3,3V @1A
WEBENCH Designer Automotive Power Converter 3.3V @1A First, it is best to apply for an account so that your design will be saved in it. You can call it out at any time. Go to http://www.ti.com.cn/ and...
samhuang8204 Analogue and Mixed Signal
Understanding of MSP430 interrupt mechanism
[size=4]1. Interrupt nesting, priority [/size] [size=4] The control bit of the 430 general interrupt is the GIE bit in the status register (this bit is in the SR register). When this bit is in the res...
fish001 Microcontroller MCU
ESP8266 MicroPython is finally here
I finally received it today. I've been waiting for so long. I'm very happy to receive it. In the days before I received it, I soldered a piece based on ESP8266 MicroPython. I burned the program into i...
qwerghf MicroPython Open Source section
[Runhe Neptune Review] Four network communications
Wireless connection:Our W800 is a SOC with built-in WIFI, so its focus is on wireless networking. I will just briefly explain the application process: the device needs to connect to the router wireles...
hl23889909 Real-time operating system RTOS
How to send data received from one network card to another network card?
I want to implement NAT and share the Internet under NDIS. The solution is: the IP packets received on the intranet are sent from the public network card after being reshaped. Then the IP packets rece...
zhtong198619 Embedded System
Urgently needed: signal generator
Requirements for the graduation project of a multi-waveform signal generator: 1. Realize at least three waves, sine wave, square wave, triangle wave, and sawtooth wave, preferably using a single-chip ...
sun21342134 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development