Dual Display Digital Pressure Sensor
For Gas
DP-100
SERIES Ver.2
Related Information
■
General terms and conditions............. F-3
■
Glossary of terms........................ P.1563~
■
Korea’s S-mark ............................. P.1602
■
Selection guide ............................. P.699~
■
General precautions ..................... P.1566
Ver.2
Recognition
Certified
[DP-101(A)/102(A) only]
* Passed the UL 991 Environment Test
* UL 61010C-1 compatible, Passed the UL 991
Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor
manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended
use: UL 991, SEMI S2-0200]
panasonic.net/id/pidsx/global
Digital
Auto reference With analog
output
Dual 3-color display makes operation easier!
Achieved further efficiency with 4 upgrades, keeping the same operability
UPGRADE 1
Superior visibility
Improved visibility in Digital Display
Improvements to the digital display deliver a wide
viewing angle along with increased clarity. The display
pressure range and set pressure range have also been
increased.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Old DP-100 series
New DP-100 series
DP-0
DP-100
DP-M
UPGRADE 2
Long-distance transmission of analog output
Addition of analog current output capability to multifunctional models
Users can now select either voltage output or current output as analog output according to their application.
Dual Display Digital Pressure Sensor
DP-100
SERIES Ver.2
714
FIBER
SENSORS
APPLICATIONS
Confirming suction of electronic component
Confirming reference pressure
Air-leak test for PET bottles
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
UPGRADE 3
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Reduced environmental impact
14 % lower power consumption (during normal operation)
Thanks to a redesign of its circuitry, power consumption
of the low-power-consumption
DP-100
series during
normal operation has been reduced by 14 %. The
display is shut off entirely during ECO / FULL mode
operation for power savings of up to 50 % compared
to normal operation, and display brightness is lowered
during ECO / STD mode operation for power savings of
up to 30 % compared to normal operation.
14 %
lower
after update
Old DP-100 series
New DP-100 series
840 mW (normal operation) 720 mW (normal operation)
Up to
50 %
lower
in ECO mode
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
Normal operation ECO / FULL operation
720 mW
360 mW
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
UPGRADE 4
Enhanced power circuitry
Addition of a reverse polarity protection circuit to the transistor output circuit
To prevent from breakage due to miswiring.
“Current value” and “threshold value” can be checked at the same time!
Dual display allows direct setting of threshold value
Equipped with a 30 mm
1.181 in
square compact-sized dual display. The
current value and the threshold value can be checked at the same time, so
the threshold value can be set and checked smoothly without switching to
another screen mode. ON/OFF operations still continue while the threshold
values are being set, so setting to the same sensitivity as dial control-type
sensors is possible. Key lock function is equipped as well.
Current
value
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DP-0
DP-100
DP-M
Threshold
value
715
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Dual Display Digital Pressure Sensor
DP-100
SERIES Ver.2
3-color display (Red, Green, Orange)
The main display changes color in line with changes
in the status of output ON/OFF operation, and it also
changes color while setting is in progress. The sensor
status can therefore be understood easily, and operating
errors can be reduced.
Main
Display
OFF: Green (or Red)
ON: Red (or Green)
SET: Orange
Readable digital display!
Alphanumeric indication in 12 segments is used. This
improved visual checking.
During normal operation
During setting
BASIC PERFORMANCE
All models in the line-up are compound pressure types
No sensor settings are required to switch between positive pressure and negative
pressure, so that the number of registered part numbers can be decreased.
Ideal for applications such
as suction.
No mis-operations due to
vacuum breakdown occur.
–100 kPa
0 kPa
100 kPa
High performance accomplished
Low pressure type
The low pressure type displays measurements in 0.1 kPa
at a resolution of 1/2,000 and has a response time of 2.5
ms (variable up to 5,000 ms), ±0.5 % F.S. temperature
characteristics and ±0.1 % F.S. repeatability, giving it
high performance.
Resolution: 1/2,000
Response time: 2.5 ms
Temperature characteristics: ±0.5 % F.S.
Repeatability: ±0.1 % F.S.
<For low pressure>
For low
pressure
For high
pressure
DP-101
Ideal for applications such as
checking reference pressure.
Can also be used for simple
suction.
1 MPa
<For high pressure>
DP-102
Displays measurements in 0.1 kPa
FUNCTIONS
Copy function reduces man-hours and human error
Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data
to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when
machinery design are changed, there would be less change in work orders.
Details transmitted
Copying via wiring
Master sensor
+V
0V
Power supply
+V
0V
Comparative output 1
Comparative output 2
Slave sensor
Detail
Details received
s cop
ied
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Comparative output 1
Comparative output 2
Note: Settings cannot be copied from the new version (Ver. 2) to the old version.
However, settings can be copied from the old version to the new version (Ver. 2).
DP-0
DP-100
DP-M
The sensor’s setting operation mode has a 3-level configuration to suit the frequency of use
The setting levels are clearly separated into “RUN mode”
for operation settings that are carried out daily, “MENU
SETTING mode” for basic settings, and “PRO mode”
for special and detailed setting. These make setting
operations easy to understand and easy to carry out.
RUN mode
Settings such as threshold value
adjustment and key lock operation
can be carried out while the sensor
is operating.
MENU SETTING mode
Simple setting
RUN mode
MENU SETTING mode
Basic settings such as output mode
setting and NO/NC switching can be
carried out.
PRO mode
Special and
detailed setting
PRO mode
High-level function settings such as
hysteresis adjustment and the copy
function can be carried out.
Dual Display Digital Pressure Sensor
DP-100
SERIES Ver.2
716
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
FUNCTIONS
Equipped with independent dual output and three output modes
Equipped with two independent comparative outputs,
and separate sensing modes can be selected for each
of them. Since there are two comparative outputs, one
of the comparative outputs can even be used for alarm
output. In addition, output, which is not being used, can
be disabled.
Vacuum breakdown can also be notified during suction applications!
ON
Comparative output 1
EASY mode
OFF
1
Standard type
EASY mode
This mode is used for comparative output ON/OFF control.
Pressure
P
H (Hysteresis)
0
ON
Comparative output
OFF
H: Fixed
Suction checking
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “
”appears in the sub display for comparative output 1, and
“
” appears for comparative output 2.
2
Hysteresis mode
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
ON
Comparative output 2
EASY mode
OFF
–100 kPa
This mode is used for setting comparative output hysteresis
to the desired level and for carrying out ON/OFF control.
Vacuum breakdown checking
Pressure
P-1
0 kPa
P-2
Hi
H (Hysteresis)
Reference pressure alarm output is possible during reference pressure checking!
ON
Comparative output 1
Hysteresis mode
OFF
Reference
pressure
checking
Lo
0
ON
Comparative output
OFF
H: 1 digit or more
Note: “
” or “
output 1, and “
3
” appears in the sub display for comparative
” or “
” appears for comparative output 2.
Window comparator mode
Pressure
ON
Comparative output 2
EASY mode
OFF
0 kPa
Lo-1
Hi-1
Alarm output
This mode is used for setting comparative output ON
and OFF at pressures within the setting range.
H (Hysteresis)
Hi
H (Hysteresis)
P-2
Lo
0
ON
Comparative output
OFF
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
H: Fixed
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “
” or “
” appears in the sub display for comparative
output 1, and “
” or “
” appears for comparative output 2.
Possible to switch over analog output and external input
Multi-function type
Multi-function type that enables the selection of analog output (voltage/current) or external input (auto-reference/
remote zero-adjustment) is available. It complies a wide range of applications.
Comparative output
is lighting.
Voltage Low pressure type: 1 to 5 V,
High pressure type: 0.6 to 5 V
Current Low pressure type: 4 to 20 mA,
High pressure type: 2.4 to 20 mA
Auto-reference/remote zero-adjust
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Selection
Multi-function type
Analog output
or
DP-0
DP-100
DP-M
External input
717
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Dual Display Digital Pressure Sensor
DP-100
SERIES Ver.2
FUNCTIONS
Equipped with auto-reference/remote zero-adjustment functions. More precise pressure management is achieved with a minimum of effort
Multi-function type
If the reference pressure of the device changes, two functions are selectable.
One is auto-reference function, which partially shift the comparative output
judgment level by the amount that the reference pressure shifts. The other
is remote zero-adjustment function, which can reset the display value to zero
via external input. These functions are ideal for places where the reference
pressure fluctuates wildly, or where fine settings are required.
With auto-reference function applied
Comparative output: Window comparator mode
Hi-1…0, Lo-1…–5
Sets the absolute threshold level
Auto-reference input
The display remains at “30” and
only the threshold level is changed.
With remote zero-adjustment function applied
Comparative output: Window comparator mode
Hi-1…0, Lo-1…–5
Sets the absolute threshold level
Remote zero-adjustment input
The display is forced to “0”, and only the
filling pressure drop range is displayed.
30
25
20
15
30
OK
Threshold level after applying
auto-reference input
Threshold level before applying
auto-reference input
Trial 1
25
20
15
0
–5
OK
Threshold level after applying
remote zero-adjustment input
Threshold level before applying
remote zero-adjustment input
Trial 1
Pressure 0
–5
Pressure 0
Auto-reference input value…
Time
–5
When auto-reference input is applied, the reference pressure “30”
is added to the threshold level. If the reference pressure changes
to “20” or “40”, the auto-reference input compensates for this
every time by changing the threshold level, so any variation in
the filling pressure can be ignored.
When remote zero-adjustment input is applied, the reference
pressure is forced to “0”. If the reference pressure changes to
“20” or “40”, the remote zero-adjustment input adjusts the
reference pressure to “0” every time the reference pressure
changes, so any variation in the filling pressure can be ignored.
Time
Displayed when remote zero-adjustment
input is applied…
Sub display can be customized
The sub display can be set to indicate any other desired
values or letters apart from the threshold value. This
eliminates the need for tasks such as affixing a label to
the device to indicate the normal pressure value.
Setting details can be recognized at a glance
The
DP-100
setting details appear in the digital display.
Because the settings are in numeric form that can be
easily understood, it is useful such as when receiving
technical support by telephone.
2nd digit: Setting status for
comparative output 2
1st digit: Setting status for
comparative output 1
3rd digit: Threshold value setting
4th digit: Display color setting
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DP-0
DP-100
DP-M
5th digit: Response time
setting
6th digit: Display unit setting
8th digit: ECO mode setting
7th digit: Display refresh rate setting
Peak hold and Bottom hold functions
The peak values and bottom values for fluctuating
pressures can be displayed using the dual display.
Energy-saving design! Equipped with an ECO mode
This mode lowers the display luminance to cut power
consumption by approximately 30 %. The displays can
also be turned off completely to achieve a power saving
of approximately 50 %.
Normal
Approx.
ECO-STD
30 % less
Power consumption
Power consumption
ECO-FULL
50 % less
Approx.
Blinks alternately
Current consumption for
24 V power supply:
30 mA or less
Current consumption for
24 V power supply:
20 mA or less
Current consumption for
24 V power supply:
15 mA or less