NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified
Safety Specifications
Parameters
Agency Approvals
Safety Standards
CE
EN 55032, Class B(With recommended EMC circuit)
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-6
IEC61000-4-8
www.aimtec.com
F 051e R6.G
Rev: 05/20/A
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM1DR-Z
1 Watt | DC-DC Converter
Typical Efficiency Example Charts
AM1DR-0505SZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
20%
40%
60%
Loading %
80%
100%
Eff %
AM1DR-1215SZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
20%
40%
60%
Loading %
80%
100%
Eff %
AM1DR-2405SZ Efficiency vs. Loading
100
90
80
70
60
50
40
30
20
10
0
20%
40%
60%
Loading %
80%
100%
www.aimtec.com
F 051e R6.G
Rev: 05/20/A
Eff %
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM1DR-Z
1 Watt | DC-DC Converter
Pin Out Specifications
Pin
1
2
4
5
6
7
Dimensions
19.50
(0.77)
7.20
(0.28)
PRINTED
FACE
9.50
(0.37)
10.0
(0.39)
1000VDC
+ V Input
- V Input
- V Output
No pin
+ V Output
No pin
3000VDC
+ V Input
- V Input
No pin
- V Output
No pin
+ V Output
0.50
(0.02)
2.54
(0.10)
4.10
(0.16)
15.20
(0.60)
0.50
(0.02)
7.20
(0.28)
0.50
(0.02)
1.25
(0.05)
0.25
(0.01)
Radiated and Conducted Emissions Application circuit:
C1
470µF/100V
L1
12 µH
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.