Load voltage regulation (Single) 3.3V output model
Load voltage regulation (Dual)
Load voltage regulation (Dual) 3.3V output model
Temperature coefficient
Ripple & Noise
Rising time
Conditions
For 1% change of Vin
For 1% change of Vin
Load 20 – 100%
Load 20 – 100%
Load 20 – 100%
Load 20 – 100%
At 20MHz Bandwidth
Typical
Maximum
Units
%
%
%
%
%
%
%
o
%/ C
mV p-p
ms
±3
Momentary (1 sec)
±1.2
±1.2
±10
±20
±10
±20
±0.02
100
50
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions
(L x W x H)
MTBF
Conditions
100% load
Full Load without Derating
Typical
80
-40 to+85
-55 to +125
Maximum
Units
KHz
o
C
o
C
o
C
%
g
90
Free air convection
90
Non-conductive black plastic
1.8
0.50 x 0.40 x 0.27 inches
12.70 x 10.16 x 6.85 mm
o
>1 191 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25 C)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 051e R11.G
CE
EN55022 (Radiated Emissions) class B
EN55024 (Noise Immunity), IEC61000-4-2(ESD)
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1P-Z
1 Watt | DC-DC Converter
IEC61000-4-3(Radiated immunity)
Pin Out Specifications
Pin
1
4
5
6
7
8
1000 and 3000 VDC
Single
Dual
- V Input
+ V Input
+ V Output
No pin
- V Output
No pin
- V Input
+ V Input
+ V Output
No pin
Common
- V Output
1000 VDC
Dual Separated
- V Input
+ V Input
+ V1 Output
- V1 Output
+ V2 Output
- V2 Output
Dimensions
12.70
(0.50)
0.50
(0.02)
7.62
(0.30)
1
10.16
(0.40)
7.62
(0.30)
8
Bottom View
4
7
6
5
2.54
(0.10)
6.85
(0.27)
3.05
(0.12)
2.54
(0.10)
0.50
(0.02)
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
7.