LTGOO51A-TW-W-R/28V

Description
Rocker Switch, DPST, Momentary, Solder Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size112KB,1 Pages
ManufacturerCarling Technologies
Environmental Compliance  
Download Datasheet Parametric View All

LTGOO51A-TW-W-R/28V Overview

Rocker Switch, DPST, Momentary, Solder Terminal, Rocker Actuator, Panel Mount

LTGOO51A-TW-W-R/28V Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width25.24 mm
body height20.62 mm
Body length or diameter28.45 mm
Contact (AC) maximum rated R load15A@125VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)125 V
Electrical life25000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial numberLTG
Installation featuresPANEL MOUNT
Maximum operating temperature66 °C
Minimum operating temperature
surface mountNO
Switch actionMOMENTARY
switch functionDPST
Switch typeROCKER SWITCH
Termination typeSOLDER
Carling
Technologies
TG/LTG-Series Rocker Switches
TG/LTG-Series Rocker Switches
The TG-Series Mini Tippette rocker switches are single or
double pole and feature an all nylon double-insulated con-
struction. These switches are designed with snap-in mount-
ing for fast, low cost assembly. The illuminated version
(LTG) is available with either a paddle or rocker actuator.
These AC rated switches are also suitable for low-voltage
DC applications in a wide range of markets including
Appliance, HVAC, Food service, and Transportation.
Dielectric Strength
UL/CSA:
1000V - live to dead metal parts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 150°F (0°C to +65.6°C)
.069[1.75] DIA
.156[3.96] DIA
.055[1.40] DIA
6.000[152.40]
.375[9.52]
.250[6.35]
.500[12.70]
1.155[29.33]
.865[21.97]
.050[1.27]
1.240[31.50]
.250[6.35]
.250 TAB (Q.C.)
.250[6.35]
SOLDER LUG
.187[4.74]
.187 TAB (Q.C.)
INTEGRATED WIRE LEAD
(no exposed conductors)
TERMINAL TYPE
.210[5.33]
.812[20.62]
.520[13.20]
1.125[28.57]
.375[9.52]
1.120[28.45]
PADDLE
1.000[25.40]
.994[25.24]
MOUNTING HOLE
Panel Thickness:
.030[.762] min. to
.250[6.35] max.
LTG G O 50 1
-
T B
-
B
-
R
/
125N
1
Base Part Number
2
Circuit
3
Center
Position
4
Rating
5
Termination
6
Actuator
Style
7
Actuator
Color
8
Base Color
9
Lens Color
10
Lamp
Voltage
1 BASE PART NUMBER: SERIES
1
TG
Double Pole, Non-Lighted
LTG
Double Pole with Indicator Lights
2 CIRCUIT
See Circuit Designation Chart Page 17.
3 CENTER POSITION
C
Center OFF, Three position
O
No Center OFF, Two position
4 RATING
40
5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC
41
5A 250VAC, 10A 125VAC
50
10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC
51
10A 250VAC, 15A 125VAC
5 TERMINATION/FUNCTION
solder lug
ON-NONE-OFF
0
(ON)-NONE-OFF
A
ON-NONE-(OFF)
L
ON-NONE-ON
0
ON-NONE-(ON)
A
ON-OFF-ON
0
6 ACTUATOR STYLE
P
paddle
7 ACTUATOR COLOR
2
B
black
8 BASE COLOR
2
B
black
9 LENS COLOR
3
A
amber
10 LAMP VOLTAGE
incandescent
6V
6 volt
12V
12 volt
18V
18 volt
24V
24 volt
28V
28 volt
wire leads
5
F
T
5
F
5
T
rocker
W
white
W
white
C
clear
R
red
neon
125N
125 volt neon
250N
250 volt neon
.250 tab QC
1
B
M
1
B
1
.187 tab QC
3
D
R
3
D
3
NOTES
Imprinting is available. Consult factory.
Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same direction as the punch. (Burr on bottom.) Test cut hole in actual material.
1
TG available with circuits A, B, C, D, E, F ; LTG available with circuits G, H, I, J, M, N, P, Q, R, T, U, V, Y, Z. See page 17.
2
Custom colors are available. Consult factory.
3
Specify lens color for LTG-Series only.
()
Indicates momentary function.
14
www.carlingtech.com
Kneeling down in the snow to ask for help: Friends, who knows about IP communications, please come in and tell me
[b] [color=red][/color][/b] [b][font=Times New Roman][color=red] [/color] [/font][/b][font=宋体]Our company has more than 100 people and we want to replace the traditional telephone system we are curren...
yp20091130 Industrial Control Electronics
"Operational Amplifier Parameter Analysis and LTspice Application Simulation" 2. Chapter 2 Bias Current
[i=s]This post was last edited by ddllxxrr on 2021-5-16 15:55[/i]This chapter really shocked me, because I didn't understand a lot of the knowledge. This is how I have been for many years. It’s quite ...
ddllxxrr Analog electronics
LPC1788 LWIP runs abnormally as a server
Recently, I am using LPC1788 to debug Ethernet communication. Based on LWIP, LPC1788 is used as an Ethernet server. The purpose is to achieve normal control to receive data sent by the host computer. ...
anxin_1008 NXP MCU
Good news for installing IAR in Windows 8
If you are using Windows 8, have you ever had trouble installing IAR? Have you ever been annoyed that you can't operate after installation? Have you ever been annoyed that you can't download during si...
aihaiduo Microcontroller MCU
MSP430FR5739 can't figure out the serial port
I have been using ARM11, ARM9, ARM7, 51 before, but never MSP430. I just bought an MSP430FR5739 development board. I just want a simple serial port routine, but I can't find it. When the system starts...
pppoepppoe Microcontroller MCU
Graduation Project of Flammable Gas Alarm Based on AT89C51
Here is a complete set of flammable gas alarm graduation project based on at89c51. If you need it, please contact me, QQ: 363028096, Tel: 13571841736[font=仿宋_GB2312] [/font]...
雨326 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 733  1073  1729  1362  1876  15  22  35  28  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号