20~25W AC-DC Single Output Desktop
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Class power (with earth pin)
Full output 5~48V safety approval
ES25A
series
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
PWM 3842 control circuit and regulated
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CB / FCC / CE
1 year warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
OUTPUT
RATED POWER (max.)
VOLTAGE TOLERANCE
Note.4
LINE REGULATION
LOAD REGULATION
Note.5
Note.6
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ES25A05-P1J ES25A07-P1J ES25A09-P1J ES25A12-P1J ES25A15-P1J ES25A18-P1J ES25A24-P1J ES25A28-P1J ES25A36-P1J ES25A48-P1J
ES25A05-050 ES25A07-075 ES25A09-090 ES25A12-120 ES25A15-150 ES25A18-180 ES25A24-240 ES25A30-280 ES25A36-360 ES25A48-480
Note.2
5V
7.5V
2.93A
22W
80mVp-p
5.0%
1.0%
5.0%
9V
2.77A
25W
80mVp-p
5.0%
1.0%
5.0%
12V
2.08A
25W
80mVp-p
3.0%
1.0%
3.0%
15V
1.66A
25W
100mVp-p
3.0%
1.0%
3.0%
18V
1.38A
25W
150mVp-p
3.0%
1.0%
3.0%
24V
1.04A
25W
180mVp-p
2.0%
1.0%
2.0%
28V
0.89A
25W
240mVp-p
2.0%
1.0%
2.0%
36V
0.69A
25W
240mVp-p
2.0%
1.0%
2.0%
48V
0.52A
25W
240mVp-p
2.0%
1.0%
2.0%
4.0A
0.4 ~ 4.0A
20W
5.0%
1.0%
5.0%
0.3 ~ 2.93A 0.2 ~ 2.77A 0.1 ~ 2.08A
0.1 ~ 1.66A 0.1 ~ 1.38A 0.1 ~ 1.04A 0.1 ~ 0.89A 0.06 ~ 0.69A 0.05 ~ 0.52A
RIPPLE & NOISE (max.)
Note.3
50mVp-p
SETUP, RISE, HOLD UP TIME
600ms, 50ms, 16ms at full load
90 ~ 264VAC 135 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
47 ~ 63Hz
70%
72%
76%
76%
78%
80%
82%
82%
82%
82%
0.7A / 100VAC
40A / 230VAC
0.75mA / 240VAC
130 ~ 180% rated output power
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Recovers automatically after fault condition is removed
0 ~ +50 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336 approved
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
SAFETY &
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B
(Note. 7)
HARMONIC CURRENT
Compliance to EN61000-3-2,3
EMS IMMUNITY
MTBF
DIMENSION
PACKING
PLUG
CABLE
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25 )
93*54*36mm (L*W*H)
250g ; 60pcs / 15kg / CARTON
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
Standard type UL1185 6ft (with ferrite core) for stock ; Other type available by customer requested
OTHERS
CONNECTOR
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:ES25A-SPEC 2008-05-23