Search

333-3-052-1-F-RR1-1150

Description
Board Connector, 52 Contact(s), 2 Row(s), Male, Right Angle, 0.079 inch Pitch
CategoryThe connector    The connector   
File Size1MB,1 Pages
ManufacturerMPE-Garry GmbH
Download Datasheet Parametric View All

333-3-052-1-F-RR1-1150 Overview

Board Connector, 52 Contact(s), 2 Row(s), Male, Right Angle, 0.079 inch Pitch

333-3-052-1-F-RR1-1150 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Board mount optionsPEG
body width0.157 inch
subject depth0.327 inch
body length2.054 inch
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU
Contact point genderMALE
Contact materialCOPPER ALLOY
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Dielectric withstand voltage700VAC V
insulator materialTHERMOPLASTIC
Manufacturer's serial number333
Plug contact pitch0.079 inch
Match contact row spacing0.079 inch
Installation methodRIGHT ANGLE
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
PCB contact patternRECTANGULAR
Rated current (signal)1.5 A
GuidelineUL
reliabilityCOMMERCIAL
Terminal pitch2.0066 mm
Total number of contacts52
Pin Header SMD Right Angled 2,00 mm
Rated current
1,5 A
Rated voltage
150 V
RMS
/ V
DC
Withstand voltage
500 V
RMS
for one minute
Material contact
Copper alloy
Material insulator
High temp. thermoplast UL94V-0
Operating temperature -40°C to +105°C
Max. processing temper. 260°C for 10 seconds
All dimensions in mm.
Series
333
pitch
termination
contact
size
2,00
Product
group
3
Variation
PCB Layout
036 / 072
max.
pincount
0,50
2,00
B
1,00
1
ø0,80
0,50
(n-2) x 2,00
1,00
2,00
0,75
1,53
2,81
ø1,00
(n-2) x 2,00
4,00
2,00
2,00
B
2
ø1,00
0,50
(n-2) x 2,00
1,30
2,00
1,00
2,81
6,30
1,60
1,30
8,25
3,25
ø1,20
(n/2-2) x 2,00
4,00
2,00
2,00
3
4,10
2,27
1,30
1,60
3,00
1,27
6,30
ø1,00
2,00
0,50
(n-2) x 2,00
ø0,85
ø1,20
(n/2-2) x 2,00
7,51
8,31
8,76
11,50
12,30
12,75
** Positioning peg
0 = Without peg
1 = With peg
Plating:
T = Sn
F = Au
S = Selective Au
Packaging:
R = Reel
T = Tube
No. of contacts *
(004,... - 072)
Variation (1,2,3)
A
3,20
4,00
4,45
3,20
4,00
4,45
Plating contact (T,F,S)
B
1
1
1
available in variation
see figure left
see figure left
2
2
2
3
3
3
Positioning peg (0,1)
A (1/100 mm)
* No. of contacts:
Variation 1 = 004 - 036
Variation 2 = 006 - 072
Variation 3 = 006 - 072
Cap:
0 = Without cap
1 = With cap
e.g. 1000 = 10,00 mm
Packaging (R,T)
Cap (0,1)
www.mpe-connector.de
Order code:
333-?-???-?-?-R??-????
4-14 4-15 4-16 4-17 4-18
3-30
Mating series
see page
156 159 422 158 413 160
6-8
3,30
(n/2) x 2,00
(n/2-1) x 2,00
B
A
1,00
(n/2-1) x 2,00
2,00
2,00
3,30
(n/2) x 2,00
(n/2-1) x 2,00
A
1,00
(n/2-1) x 2,00
2,00
2,00
n x 2,00
(n-1) x 2,00
A
(n-1) x 2,00
2,00
MPE-Garry GmbH • Schäfflerstraße 13 • 87629 Füssen • Germany • Phone: +49 (0) 83 62 / 91 56-0 • Fax: +49 (0) 83 62 / 91 56-500 • Email: vk@mpe-connector.de • www.mpe-connector.de
Inductor and transformer testing methods and experience
3. Inductor and transformer detection methods and experience 1. Detection of color-coded inductors Set the multimeter to R×1, and connect the red and black test leads to any lead-out terminal of the c...
fighting Analog electronics
Can the official APP directly display humidity and power level?
[i=s]This post was last edited by Liang Zhijian on 2017-4-9 17:48[/i] I directly soldered the core board to the small board and powered it on. On the official APP with version number 3.3, I saw temper...
梁志坚 MEMS sensors
After debugging, CCS directly runs 8 cores.
I have been debugging C6678 these two days. It was working fine before. But now, after debugging the same project, all 8 cores are running directly without any other operations. The same happens when ...
taoranae86 DSP and ARM Processors
Help!!! Course Design - Detection of DC Motor Working Current
The teacher gave me this question and told me to use Protel to solve it. I have no idea how to do it. Can any expert give me some advice?...
ljx19851226 Test/Measurement
Driver novice help!
I recently disassembled a driver, but I know very little about it. Please help! There are two key functions at the beginning of the driver, which I don't quite understand. I guess my problem is relati...
860122 Embedded System
Asynchronous IO principles and corresponding functions
What is asynchronous IO? (1) It can be considered that asynchronous IO is an interrupt response system implemented by software in the operating system.(2) The working method of asynchronous IO is: our...
灞波儿奔 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2757  1980  1220  1832  1377  56  40  25  37  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号