EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-111-28-2350RLF

Description
Board Connector, 56 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Kinked Leads Terminal, Locking, Black Insulator, Receptacle,
CategoryThe connector    The connector   
File Size107KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

54122-111-28-2350RLF Overview

Board Connector, 56 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Kinked Leads Terminal, Locking, Black Insulator, Receptacle,

54122-111-28-2350RLF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid306021962
Reach Compliance Codecompliant
Country Of OriginFrance
ECCN codeEAR99
YTEOL9.4
body width0.19 inch
subject depth0.925 inch
body length2.8 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedMatte Tin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialPOLYETHYLENE
JESD-609 codee3
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness30u inch
Rated current (signal)3 A
GuidelineUL, CSA
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER KINKED LEADS
Total number of contacts56
PDM: Rev:K
STATUS:
Released
Printed: Mar 10, 2011
.
How to display variables as waveforms in CCS?
It doesn't necessarily need to be displayed in real time. I'm new here and don't know how to use CCS5.5. Some people say to go directly to file--->data--->save, and then use matlab to display it, but ...
深蓝漓落 Microcontroller MCU
Detailed analysis of the working mode of the microcontroller IO port
The working modes of the microcontroller I/O port are basically divided into the following categories: 1. Quasi-bidirectional IO port configuration (weak pull-up) summary: Strong current sinking capab...
灞波儿奔 Microcontroller MCU
【TI Classic】Power Supply Design Experience-Collection
Continuing to share good stuff with you, TI's community has produced a set of power design experience collection e-books, which contain detailed explanations of 1-50 power design tips. The expert's na...
德州仪器 Analogue and Mixed Signal
【Hanker TI M4】Part 1 Jlink Upgrade + Project Settings
JLink V8 +MDK5.12 1. JLink firmware upgrade. I used to install MDK4.71, and then I changed to MDK5.12 and never used JLink. After plugging in JLink, it prompted to upgrade. I accidentally clicked the ...
ltbytyn Microcontroller MCU
What's the use of these?
In the platform.reg registry, [HKEY_CURRENT_USER\......\USB] "Entry"=hex:\ 08,02,40,00,00,00,00,00,00,00,00,00,00,00,0f,00,00,00,00,00,64,ce,e3,03,00,\ 00,00,00,00,00,00,00,67,00,00,00,e0,e8,04,16,28,...
yuezhiguang.4 Embedded System
How to customize a system with the same functions as Windows Mobile 6.0
How can I customize a system with the same functions as Windows Mobile 6.0? I hope an expert can explain it to me! Thanks in advance!...
zoloq Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2568  247  2240  2432  1718  52  5  46  49  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号